Page 37
Programming
Programming The reader is factory-configured with a set of standard default features. After scanning the interface barcode from the Interfaces section, you can select other options and customize your reader through use of the instructions and programming barcodes available in the Gryphon™ I GD4100/GM4100 Product Reference Guide (PRG). Check the corresponding features section for your interface, and also the Data Editing and Symbologies chapters of the PRG.
Using the Programming Barcodes This manual contains barcodes which allow you to reconfigure your reader. Some programming barcode labels, like the Standard Product Default Settings on page 33, require only the scan of that single label to enact the change. Other barcodes require the reader to be placed in Programming Mode prior to scanning them. Scan an ENTER/EXIT barcode once to enter Programming Mode, scan the desired parameter settings, then scan the ENTER/EXIT barcode a second time to accept your changes, exit Programming Mode and return the reader to normal operation.
Configure Other Settings Additional programming barcodes are available in the Gryphon™ I GD4100/GM4100 PRG to allow for customizing programming features. If your installation requires different programming than the standard factory default settings, refer to the PRG.
Resetting Standard Product Defaults If you aren’t sure what programming options are in your reader, or you’ve changed some options and want the factory settings restored, scan the Standard Product Default Settings barcode below to copy the factory configuration for the currently active interface to the current configuration. Factory defaults are based on the interface type. Configure the reader for the correct interface before scanning this label. NOTE
Standard Product Default Settings
Quick Reference Guide
33
Page 38
Technical Specifications
Technical Specifications The following table contains Physical and Performance Characteristics, User Environment and Regulatory information. Item
Description
Physical Characteristics Color
White/Gray Black/Gray
Dimensions
Height 7.1”/181 mm Length 3.9”/100 mm Width 2.8”/71 mm
Weight (without cable)
Approximately 8.7 ounces/246 g (reader with display) 8.7 ounces/246 g (base charger)
Electrical Characteristics Battery Type
Li-Ion battery pack 4 hours with external power supply adaptera
Charge time for full charge max 22h hours with Host power from full discharge (in this case no supply adapter is needed)a Operating autonomy (continuous reading)
50,000 reads (typical)
Cradle consumption Volt 4.75-14 VDC; Power <8Wb; and DC input supply range Imax 500mA when in host/bus powered modeb. Performance Characteristics Light Source
LEDs
Roll (Tilt) Tolerance
± 35° from normal
Pitch Tolerance
± 65°
Skew (Yaw) Tolerance
± 65°
Field of View
10” (25.4cm) wide at 12.5” (31.8cm) from the reader
Depth of Field (Typical)c
3 mil – 2.9” to 4.7” (7.5cm to 12cm) 13 mild – 1.2” to 23.6” (3cm to 60cm) 20 mil – 1.2” to 31.5” (3cm to 80cm)
Minimum Element Width
3 mil
34
Gryphon™ I GM4100
Page 39
Technical Specifications
Item
Description
Print Contrast Minimum
15% minimum reflectance
Decode Capability
UPC/EAN/JAN, P2 /P5 add-ons; Code 39; Italian Pharmacode 39; Code 128; C128 ISBT; Code 128 addons; I 2 of 5; Standard 2 of 5; Code 11;Codabar; EAN 128; Code 93; MSI; GS1 DataBar™ Omnidirectional, GS1 DataBar™ Limited, GS1 DataBar™ Expanded; Code4, Code5.
Interfaces Supportedd
RS-232 Std, RS-232 Wincor-Nixdorf, RS-232 OPOS, IBM 46xx (ports5B and 9B), USB Com Std., USB Keyboard, USB Alternate Keyboard, USB OEM, Keyboard Wedge (AT with or w/o Alternate Key, IBM AT PS2 with or w/o Alternate Key, PC-XT, IBM 3153, IBM Terminals 31xx, 32xx,34xx, 37xx make only and make break keyboard, Digital Terminals VT2x, VT3xx, VT4xx, and Apple) and Wand Emulation.
User Environment Operating Temperature
32° to 122° F (0° to 50° C)
Charging Temperature
32° to 104° F (0° to 40° C)
Storage Temperature
-4° to 158° F (-20° to 70° C)
Humidity
Operating: 5% to 90% relative humidity, non-condensing
Drop Specifications
Scanner withstands 18 drops from 1.8 meters (5.9 feet) to concrete
Ambient Light Immunity
Up to 100,000 Lux
Contaminants Spray/rain Dust/particulates
IEC 529-IP52 (scanner only)
ESD Level
16 KV a. Charge Times are much lower when battery is within daily typical operating condition. b. Typical input current measured under factory default configuration. c. 13 mils DOF based on EAN. All others are Code 39. All labels grade A, typical environmental light, 20°C, label inclination 10° d. See Interface Selection on page 21 for a listing of available interface sets by model type.
Quick Reference Guide
35
Page 40
Technical Specifications
Item
Description
Regulatory Electrical Safety
EMI/RFI
UL 60950, CSA C22.2 No. 60950, IEC 60950 433 MHz model 910 MHz model Europe - CE, Russia – Gost; USA/Canada – FCC/IC; Australia – Ctick; Pending: China – SRRC; Mexico – NOM + Cofetel Singapore – IDA, Pending: Brasile – Anatel
LED class safety
IEC Class 1
Radio Features
Working Center Frequency Range (in open air)
433MHz model
910MHz model
433.920 MHz
910.000 MHz
30 m
15 m
433MHz model
910MHz model
16
16
System Configuration
Max. number of devices per base station
36
Gryphon™ I GM4100
Page 41
LED and Beeper Indications
LED and Beeper Indications The reader’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. An optional “Green Spot” also performs useful functions. The following tables list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and may or may not be turned on. For example, certain indications such as the power-up beep can be disabled using programming barcode labels.
INDICATION
Power-up Beep
DESCRIPTION
LED
BEEPER Reader beeps four times at highest frequency and volume upon power-up.
The reader is in the process of powering-up.
Good Read Beep
A label has been successfully scanned by the reader.
LED behavior for this indication is configurable via the feature “Good Read: When to Indicate” (see the PRG for information.)
The reader will beep once at current frequency, volume, mono/ bi-tonal setting and duration upon a successful label scan.
ROM Failure
There is an error in the reader's software/programming
Flashes
Reader sounds one error beep at highest volume.
Limited Scanning Label Read
Indicates that a host connection is not established when the IBM or USB interface is enabled.
N/A
Reader 'chirps' six times at the highest frequency and current volume.
Reader Active Mode
The reader is active and ready to scan.
Quick Reference Guide
The LED is lit steadilya
N/A
37
Page 42
LED and Beeper Indications
INDICATION
DESCRIPTION
LED
BEEPER
Reader Disabled
The reader has been disabled by the host.
The LED blinks continuously
N/A
Green Spot is on continuously
While in Stand Mode or Trigger Stand Mode the green spot shall be on while in stand watch state.
N/A
N/A
Green Spota flashes momentarily
Upon successful read of a label, the software shall turn the green spot on for the time specified by the configured value.
N/A
N/A
Programming Mode - The following indications ONLY occur when the reader is in Programming Mode. Label Programming Mode Entry
A valid programming label has been scanned.
Label Programming Mode Rejection of Label
A label has been rejected.
Label Programming Mode Acceptance of Partial Label
In cases where multiple labels must be scanned to program one feature, this indication acknowledges each portion as it is successfully scanned.
38
LED blinks continuously
Reader sounds four low frequency beeps.
N/A
Reader sounds three times at lowest frequency and current volume.
N/A
Reader sounds one short beep at highest frequency and current volume.
Gryphon™ I GM4100
Page 43
Error Codes
INDICATION
DESCRIPTION
Label Programming Mode Acceptance of Programming
Configuration option(s) have been successfully programmed via labels and the reader has exited Programming Mode.
Label Programming Mode Cancel Item Entry
Cancel label has been scanned.
LED
BEEPER
N/A
Reader sounds one high frequency beep and 4 low frequency beeps followed by reset beeps.
N/A
Reader sounds two times at low frequency and current volume.
a. Except when in sleep mode or when a Good Read LED Duration other than 00 is selected
Error Codes Upon startup, if the reader sounds a long tone, this means the reader has not passed its automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is reset, the sequence will be repeated. The following table describes the LED flashes/beep codes associated with an error found. NUMBER OF LED FLASHES/ BEEPS
ERROR
1
Configuration
2
Interface PCB
4
Reader Module
5
Laser Pointer (if so equipped)
6
Digital PCB
14
CPLD/Code Mismatch
Quick Reference Guide
CORRECTIVE ACTION
Contact Helpdesk for assistance
39
Page 44
Base Station Indications
Base Station Indications INDICATION
LEDS
Power-up Complete
Yellow LED on
Reader Disabled by the HOST or the communication with HOST is not established
Yellow LED blinking ~1Hz
Data/labels are transmitted to the HOST
Yellow LEDs turned off for 100mSec
Programming Mode
Yellow LED blinks quickly
Configuration alignment with the HH is in progress
Red LED blinks quickly
Battery charger in progress
Red LED on
Battery charger complete
Green LED on
Battery charger error
Green LED and Red LEDs blink alternatively ~1Hz
No HH is placed on the cradle
Red and Green LEDs off
Ergonomic Recommendations CAUTION
• • • • • • • • • • • 40
In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below. Consult with your local Health & Safety Manager to ensure that you are adhering to your company’s safety programs to prevent employee injury.
Reduce or eliminate repetitive motion Maintain a natural position Reduce or eliminate excessive force Keep objects that are used frequently within easy reach Perform tasks at correct heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedures. Gryphon™ I GM4100
Page 45
Regulatory Information
Regulatory Information All models are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Any changes or modifications to equipment, not expressly approved by Datalogic could void the user's authority to operate the equipment.
Power Supply This device is intended to be connected to a UL Listed/CSA Certified computer which supplies power directly to the reader or else be supplied by UL Listed/CSA Certified Power Unit marked “Class 2” or LPS power source rated 5-14V minimum 900mA, which supplies power directly to the Base/Charger via the power connector of the Base itself.
Imager Labeling Labels are shown here to illustrate their location only. Please view the labels on your product for actual details.
Scanner Regulatory Label C R
US
10
239045
N263
INC. IC SCANNINGUSA DATALOG , OREGON EUGENE AGE FOR SEE P ACK NG PATENT LISTI PRODUCT LED CLAS S 1
Base Station Label
Quick Reference Guide
41