Charging the Batteries
• Do not place the battery pack in fire or heat. • Do not connect the positive terminal and negative terminal of the battery pack to each other with any metal object (such as wire). WARNING
• Do not carry or store the battery pack together with metal objects. • Do not pierce the battery pack with nails, strike it with a hammer, step on it or otherwise subject it to strong impacts or shocks. • Do not solder directly onto the battery pack. • Do not expose the battery pack to liquids, or allow the battery to get wet. • Do not apply voltages to the battery pack contacts. In the event the battery pack leaks and the fluid gets into your eye, do not rub the eye. Rinse well with water and immediately seek medical care. If left untreated, the battery fluid could cause damage to the eye.
CAUTION
CAUTION
Always charge the battery at 32° – 104°F (0° - 40°C) temperature range. Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Datalogic reseller. The use of any other power supplies can damage the device and void your warranty. Do not disassemble or modify the battery. The battery contains safety and protection devices, which, if damaged, may cause the battery to generate heat, explode or ignite. Do not place the battery in or near fire, on stoves or other high temperature locations. Do not place the battery in direct sunlight, or use or store the battery inside cars in hot weather. Doing so may cause the battery to generate heat, explode or ignite. Using the battery in this manner may also result in a loss of performance and a shortened life expectancy.
Quick Reference Guide
15
Page 20
Charging the Batteries
CAUTION
Do not place the battery in microwave ovens, high-pressure containers or on induction cookware. Immediately discontinue use of the battery if, while using, charging or storing the battery, the battery emits an unusual smell, feels hot, changes color or shape, or appears abnormal in any other way. Do not replace the battery pack when the device is turned on. Do not remove or damage the battery pack’s label. Do not use the battery pack if it is damaged in any part. Battery pack usage by children should be supervised.
As with other types of batteries, Lithium-Ion (LI) batteries will lose capacity over time. Capacity deterioration is noticeable after one year of service whether the battery is in use or not. It is difficult to precisely predict the finite life of a LI battery, but cell manufacturers rate them at 500 charge cycles. In other words, the batteries should be expected to take 500 full discharge / charge cycles before needing replacement. This number is higher if partial discharging / recharging is adhered to rather than full / deep discharging, The typical manufacturer advertised useful life of LI batteries is one to three years, depending on usage and number of charges, etc., after which they should be removed from service, especially in mission critical applications. Do not continue to use a battery that is showing excessive loss of capacity, it should be properly recycled / disposed of and replaced. For most applications, batteries should be replaced after one year of service to maintain customer satisfaction and minimize safety concerns. Collect and recycle waste batteries separately from the device in comply with European Directive 2006/66/EC, 2002/95/EC, 2002/96/EC and subsequent modifications, US and China regulatory and others laws and regulations about the environment.
16
Gryphon™ I GM4100
Page 21
Charging the Batteries
Replacing the Batteries
NOTE
Before proceeding, read “Battery Safety” on the preceding pages. Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum performance.
Use the following procedure to change the reader’s battery: 1.
With a screwdriver, unscrew the battery cover screw.
2.
Unplug the three screws securing the battery holder, and unplug the white connector.
Screw
Connector
Screw
Quick Reference Guide
Screw
17
Page 22
Charging the Batteries
3.
Carefully lift out the gold contacts circuit, and remove the battery holder while letting the white connector pass through the hole in the battery holder (as shown below).
Pass-through hole Gold contacts circuit
4.
Remove the old battery from its place (if present), and insert the new battery in the same position.
5.
Replace the battery holder, plug in the connector and return the contacts circuit to its previous location.
When inserting the new battery into the handle, take care to position the battery and the connector as shown. NOTE
6.
18
Insert the cover in the handle and screw it back into place.
Gryphon™ I GM4100
Page 23
Linking the Reader to a Base Station
Linking the Reader to a Base Station RF Devices For RF devices, before configuring the interface it is necessary to link the handheld with the base. To link the handheld and the base, press the trigger to wake it and place it on the base. If the reader was previously linked to another base, you must first scan the Unlink action command before relinking to the new base.
Unlink
System and Network Layouts Stand Alone Layouts Figure 8. Single Reader Layout
Quick Reference Guide
19
Page 24
System and Network Layouts
Figure 9. Multiple Reader Layout
In stand alone systems, each cradle is connected to a single Host. Figure 10. Multiple Stand Alone Layouts
Many stand alone connections can operate in the same physical area without interference, provided all readers and cradles in the system have different addresses.
20
Gryphon™ I GM4100
Page 25
Select the Interface Type
Select the Interface Type Upon completing the physical connection between the reader and its host, proceed directly to Interface Selection on page 21 for information and programming for the interface type the reader is connected to (for example: RS-232, Keyboard Wedge, USB, etc.) and scan the appropriate barcode to select your system’s correct interface type.
Interface Selection Each reader model will support one of the following sets of host interfaces: General Purpose Models: RS-232, RS-232 OPOS, USB, Keyboard Wedge Retail Point of Sale Models : RS-232, RS-232 OPOS, USB, IBM
46XX
Configuring the Interface Scan the programming barcode which selects the appropriate interface type matching the system the reader will be connected to. Next, proceed to the corresponding chapter in the Gryphon™ I GD4100/GM4100 PRG to customize any settings and features associated with that interface.
NOTE
Unlike some other programming features and options, interface selections require that you scan only one programming barcode label. DO NOT scan an ENTER/ EXIT barcode prior to scanning an interface selection barcode. Some interfaces require the scanner to start in the disabled state when powered up. If additional scanner configuration is desired while in this state, pull the trigger and hold for 5 seconds. The scanner will change to a state that allows programming with barcodes.
Quick Reference Guide
21
Page 26
Select the Interface Type
RS-232 RS-232 standard interface
Select RS232-STD RS-232 Wincor-Nixdorf
Select RS232-WN RS-232 for use with OPOS/UPOS/JavaPOS
Select RS-232 OPOS USB Com to simulate RS-232 standard interface
Select USB-COM-STDa
IBM IBM-46xx Port 5B reader interface
Select IBM-P5B
22
Gryphon™ I GM4100
Page 27
Select the Interface Type
IBM (continued) IBM-46xx Port 9B reader interface
Select IBM-P9B
USB-OEM USB-OEM (can be used for OPOS/UPOS/JavaPOS)
Select USB-OEM a. Download the correct USB Com driver from www.datalogic.com
KEYBOARD AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/ Standard Key Encoding
Select KBD-AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard
Select KBD-AT-NK AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key
Select KBD-AT-ALT Quick Reference Guide
23