The text of a manual · part 3 of 5
Formula 8500 User Manual, pages 19 to 27
Pages 19 to 27 of 44
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic F985 and Datalogic Formula 8500
Page 19
CONNECTIONS________________________________________________________
4
❏ RF Connection This allows the terminal to be connected to the host computer via radio frequency using the RF PCMCIA module that is with the F8500 (only for RF version), and an Access Point connected to the host computer
A SEAMLESS ROAMING
B ACCESS POINTS
ACCESS POINTS
ETHERNET - TOKEN RING
APPLICATION SERVER
Key: A) F8500 B) Access Point
Ed.: 01/99
15
Page 20
Formula 8500 - USER MANUAL __________________________________________
4.2
4
CRADLE F985
Only the F985 cradle can be used with the Formula 8500 terminal:
A B C D
E F G F
Key F985 standard: A) IrDA window B) Two-color LED – spare battery slot C) Terminal-recharge contacts D) Two-color LED – terminal battery E) Contacts for recharging the spare battery F) Connectors for connecting to the host computer G) Power-supply connector 16
Ed.: 01/99
Page 21
CONNECTIONS________________________________________________________
4
B
A
C
Key F985 vehicle cradle: A) Cradle F985 B) Clip-in craddle C) Metal bracket
Ed.: 01/99
17
Page 22
Formula 8500 - USER MANUAL __________________________________________
4.2.1
4
F985 cradle
The F985 cradle is a battery charger and also functions as a serial communication interface between the host computer and the IrDA optical interface on the F8500 terminal. By inserting the terminal into the cradle as shown in the figure, its batteries can be charged. The LED (D) indicates the status of the batteries in the terminal: COLOR Constant red Flashing red/green Constant green:
DESCRIPTION Battery charging Battery charged, terminal on Battery charged, terminal off or not inserted in the cradle
The spare batteries can also be charged by inserting them into the back part of the cradle, making sure the contacts (E) are correctly positioned. The LED (B) indicates the status of the batteries in the terminal: COLOR Constant red Flashing red/green Constant green:
18
DESCRIPTION Battery charging Battery charged Battery not inserted
Ed.: 01/99
Page 23
CONNECTIONS________________________________________________________
4.2.2
4
F985 vehicle cradle
The F985 vehicle cradle has the same functions as the F985 standard cradle in terms of the terminal batteries’ charge and the serial communication interface; instead, for this cradle version the back-up batteries-charging function is not available. The F985 vehicle cradle comes with its accessories already assembled. To install it inside a vehicle driving compartment, proceed as follows: 1 - Simply mount the metal bracket; 2 - It must be have a stabilised power supply, connected to the vehicle’s battery. The power supply must have the following output characteristics:: Voltage min. 9Vdc max. 12Vdc
Power min. 11W
Coaxial Socket
Polarity: Mechanical dimensions: Metal plug length:
positive external, negative internal; External diameter: 5.5 mm Internal diameter: 2.1 mm 14 mm
ATTENTION Do not connect the cradle directly to the vehicle’s battery. Possible voltage surges can damage the cradle or cause it to malfunction. 3 - Insert the F8500 terminal only after mounting the cradle in the vehicle. ATTENTION We recommend that you detach any connections to the PCMCIA (e.g. aerial, printer) when putting the F8500 terminal into the cradle or taking it out. Proceed as in the following figures:
1
Ed.: 01/99
2
3
19
Page 24
Formula 8500 - USER MANUAL __________________________________________
3.1
4
CONNECTION CABLES
Several types of cable are available depending on the type of computer and connection. The following cables are listed with their number code (C) and production batch number (#). ❏ RS-232 connection with PC/AT or compatible: cable C407900330 (# 404682100) RJ
DB 9M
SIGNAL
1
2
TX
2
8
RTS
3
5
GND
4
7
CTS
5
3
RX
4–1 ❏ RS-232 connection with PC/XT or compatible: cable C407900310 (# 404682200) RJ
DB 25M
SIGNAL
1
3
TX
2
5
RTS
3
7
GND
4
4
CTS
5
2
RX
8–20 ❏ RS-485 connection: cable C407900300 (# 303350260) RJ 3 6 7
20
SIGNAL GND RX/TX RX/TX
Ed.: 01/99
Page 25
CONNECTIONS________________________________________________________
4
❏ Modem or Eavesdrop connection with host computer: cable C407900020 (# 404613020) RJ 1 2 3 4 5 6 7
DB 25M 2 4 7 5-13 3-12 15 14
SIGNAL TX RTS GND CTS RX
SIGNAL
RX RX TX TX
❏ Eavesdrop connection with terminal: cable C407900030 (# 404613030) RJ 1 2 3
Ed.: 01/99
DB 25M 3 2 7 4-5 8-20
SIGNAL TX RX GND
21
Page 26
USE AND FUNCTIONING 5.1
5
PCMCIA CARD
The terminal’s capabilities can be extended simply by inserting a PCMCIA card with the required function. For example, peripherals can be connected to the terminal, including: a network card; an RF communication card; a modem/fax or a flash disk capable of storing tens of Megabytes. 5.1.1
Inserting the PCMCIA card
To insert the PCMCIA card into the terminal, proceed as indicated below: 1 - Remove the rubber protection.
22
Ed.: 01/99
Page 27
USE AND FUNCTIONING _______________________________________________
5
2 - Use a screwdriver to lever out the metal tab shown in the figure.
3 - Pull the tab outwards until you feel its end stop.
4 - Insert the card with the main side facing down.
Ed.: 01/99
23