Page 71

SE4-S Type 4 integrated light curtains for external Muting sensors 24 Vdc

2-3

0.5…25 m

500 - 800 mm

14 ms

2 PNP transistor

Rx: M12 8-poles/M12 5-poles Tx: M12 4-poles (‘-W’ models) Tx: M12 4-poles/M12 4-poles (‘-T’ mod.) 35 x 40 One-way or two-way Muting Test Manual/auto Restart selection Muting time-out selection EDM selection Override

69

Page 72

PHOTOELECTRIC DEVICES FOR SAFETY

TECHNICAL DATA

Body protection with passive unit and integrated Muting SERIES

SE4-R-’T’

SE4-R-’L’

According to IEC 61496-1 IEC 61496-2 Power supply

Type 4 retroreflex light curtains

Type 4 retroreflex light curtains

24 Vdc

24 Vdc

2

2

Operating range

0.5…3 m

0.5…3 m

Controlled height

500 mm

500 mm

Response time

14 ms

14 ms

OSSD output

2 PNP transistor

2 PNP transistor

Connection active unit: M12 5-poles / M12 8-poles passive unit: non connected active unit: M12 5-poles / M12 8-poles passive unit: non connected

Dimensions (mm)

active unit: 35 x 40 passive unit: 52 x 55 active unit: 35 x 40 passive unit: 52 x 55

Device functions

Two-way Muting Test Manual/auto Restart selection Muting time-out selection EDM selection Override

One-way Muting Test Manual/auto Restart selection Muting time-out selection EDM selection Override

N° beams

Certifications

Plus functions

70

Page 73

SE4-R LINEAR Type 4 retroreflex light curtains 24 Vdc

2

0.5…25 m

500 mm

14 ms

2 PNP transistor active unit: M12 5-poles / M12 8-poles passive unit: non connected active unit: 35 x 40 passive unit: 52 x 55 One-way or two-way Muting Test Manual/auto Restart selection Muting time-out selection EDM selection Override

71

Page 74

PHOTOELECTRIC DEVICES FOR SAFETY

Accessories Shielded connector cables

Fixing brackets

CV SERIES

ST SERIES

The use of shielded cables is compulsory for the safety devices of the SE2, SE4 light curtains and for the Sx-ST2/ST4 safety sensor series.

The fixing brackets are supplied together with the safety light curtains of the SE2, SE4 and SF2 series. Standard fixing brackets (4 pcs kit) are available as accessories for the SE2 and SE4 safety light cutains, as well as orientable, anti-vibration supports. Standard fixing brackets (12 pcs kit) and antiscratch fixing brackets (4 pcs kit) are available for the SF2 safety light curtains.

- M12 axial or radial connector and cable with 4, 8 poles - Cable length: 3, 5, 10, 15, 25 m - Cable material: PVC

Unshielded connector cables CS SERIES M12 4-pole unshielded connectors are available for the connection of the Muting sensors. M12 4, 5 and 8-pole UL2464 cable connectors are available for SG2 and SG4-B series. - M12 axial or radial connector and cable with 3, 4, 5, 8 poles - Cable length : 3, 5, 7, 10, 15, 25 m - Cable material: PVC

72

The TOP-BOTTOM rotating fixing brackets help the user in the alignment phase even in the most critical conditions thanks to an 180° rotating angle and a ±10° fine adjustment angle. The rotating bracket kit is supplied together with the SG2-E light curtains and is available as an accessory for the entire SG2-B and SG4-B series.

Page 75

Safety relays

Test pieces

Muting devices

SE - SR2 SERIES

TP SERIES

LMS SERIES

To be used with the SE2, SF2, SE4, SG2 and SG4 safety light curtain series.

Light curtain test pieces with 14, 20, 30, 35, 40, 50 and 90 mm diameter.

Muting lamps: standard, tower modular, with horizontal and vertical mounting. Muting sensors: all DATASENSOR non-safety sensors can be used.

- Type 4 safety relays - Safety contacts: 3 NO 1 NC.

Connection box SE - SRT SERIES

EDM relay box CS SERIES The connection box has been developed with 3 NO contacts and 1 NC contact for signal feedback in order to simplify and ease EDM connection of the Type 2 and Type 4 safety light curtains integrated with EDM function.

- Module for Type 2 and Type 4 light curtains - Output contacts: 3 NO safety contacts and 1 NC feedback/EDM contact

Connection box for light curtains with integrated Muting function, allowing a rapid activation of the Override function using key s w i t c h e s a n d Te s t / St a r t comands via the specific push-button. Compatibile with the SE4T-L and SE4-R light curtains.

73

Page 76

PHOTOELECTRIC DEVICES FOR SAFETY

Accessories Column and floor stands

Deviating mirrors

SE - S SERIES

SE - DM SERIES

To be used with the SE2, SE4, SF2 light curtains and SE-DM deviating mirror series. Available in different heights: 800, 1000 and 1200 mm with 30 x 30 mm profile dimensions. 1500 and 1800 mm with 45 x 45 mm profile dimensions. Ground fixing plate dimensions: 240 x 240 mm.

To be used with the SE2, SE4, SF2 light curtains and monobeam Sx-ST2/ST4 safety sensor series. Available in different heights ranging 150 mm to 1800 mm. Deviating mirror dimension: 124 mm width, 6 mm depth.

Protective stands and deviating mirrors SG - PS / SG - DM SERIES Sturdy aluminium column stands for shock protection of the mirrors and safety light curtains. All the SE and SG light curtain series can be mounted inside the support as well as the SG-DM mirror series. The fixing system supplied and spherical spirit level at the stainless steel base guarantee fast installation and precise alignment. Note: please carefully follow the instructions supplied in the user manual relative to the operating distances for the correct use fo the deviating mirrors.

74

Page 77

Laser pointer

Lens shield

IP69K protection

SE - LP SERIES

SG - LS SERIES

SG - IP69K SERIES

To be used with the SE2, SE4 and SF2 to support emitter and receiver alignment.

PMMA plate to mount on the front glass of the light curtain to protect it against dust, splinters and/or drops of incandescent material. Lens shield is available for safety light curtain with a 1501800 mm controlled height.

Tubular profile for SG light curtains to guarantee IP67/IP69K protection, ideal for the typical “food” industry applications where strong detergents or aggressive agents are frequently used. Accessory is available for safety light curtain with a 1501800 mm controlled height.

Protective stands SE - P SERIES To be used with the SE2, SE4 and SF2 safety light curtains. Available in different heights ranging from 273 to 1743 mm.

75

Page 78

TEMPERATURE CONTROLLERS COMPLEMENTARY PRODUCTS

THE series

THQ series

1/8 DIN mP-based controllers

1/16 DIN mP-based controllers

THT series 1/16 DIN basic and advance controllers

76

- Standard 48x96 mm format - Versions with 2 or 3 control points - PID action with ADT autoadaptive - Diagnostic of the regulation loop - Automatic or manual regulation

- Standard 48x48 mm format - Panel configurable parameters - TC-J/K and RTD Pt100 inputs - PID action with ADT autoadaptive - LFA diagnostics of the regulation loop

The THE temperature controllers, in the standard 48x96 mm format, are available in versions with single or double display, with 12-24 Vac/dc or 80-240 Vac, and 2 or 3 control points with main relay or transistor output. The main PID control action adjusts itself automatically to the optimum parameters with the AT initial autotuning, or with the ADT permanent autoadaptive function. The auxiliary outputs can be programmed on 16 different alarm functions or fixed points. The LFA diagnostic function is able to detect failures along the entire regulation loop, from the sensor to the actuator; moreover the regulation can be either automatic (closed loop) or manual (open loop), setting the output percentual value.

The microprocessor-based controllers of the THQ series are characterised by remarkable regulation precision, in particular in heat-sealing and thermoforming operations typical of the automatic packaging. The AT initial autotuning and the ADT permanent autoadaptive functions can both be activated through the PID control action, responding excellently to frequent or fast system variations, as for example in process start and stop. The panel with single or double display allows the setting of all the controller ’s values and configurations, such as sensor input, control action and alarm functions. The LFA diagnostic function is able to detect sensor, cable or heating resistance failures.

- Standard 48x48 mm format - Relay output or static output for SSR - 4-20 mA or 0-10 V analogue output - Current transformer and HBA function - RS485 serial for MODBUS-RTU protocol

The TH-T temperature controller series includes basic models suitable for more simple and costeffective applications as well as advanced models created specifically for the more evolved control and interface systems. Programming of the temperature controllers is quick and easy as the most frequently-used configurations can be set with few keyboard operations. Models with a RS485 serial interface can send the parameter configuration and receive the controlled values through an industrial PC that can control different units. Versions with a current transformer input, available as an accessory for measurements reaching 25 or 100 A, can detect even a partial load failure, as for example due to a broken heating element. The series includes models with opto-isolated relay and transistor outputs to control static relays, as well as models with 4-20 mA or 0-10 V normalised proportional analogue outputs.

Page 79

This page is a scan with no text; see it in the PDF.

Page 80

EUROPE DATALOGIC AUTOMATION Headquarters Via S. Vitalino, 13 40012 Lippo di Calderara di Reno Bologna - Italy Tel. +39 051/3147011 Fax +39 051/3147453 info.automation@datalogic.com DATALOGIC AUTOMATION IBERIA Sucursal en España C/. Samontá nº 25, 4ª Planta 08970 Sant Joan Despí, Barcelona - Spain Tel. +34 93/4772059 Fax +34 93/4777272 info.automation.es@datalogic.com DATALOGIC AUTOMATION S.R.L. Italien Filial Höjdrodergatan 21 SE-212 39 Malmö - Sweden Tel. +46 40/385000 Fax +46 40/385001 info.automation.se@datalogic.com Datalogic Automation Benelux Coltbaan 25 - 3439 NG Nieuwegein The Netherlands Tel. +31 30/6023410 Fax +31 30/6022064 info.automation.nl@datalogic.com

DATALOGIC AUTOMATION S.R.L. Niederlassung Central Europe Uracher Straße 22 D-73268 Erkenbrechtsweiler - Germany Tel. +49 7026/6080 Fax +49 7026/608849 info.automation.de@datalogic.com DATALOGIC AUTOMATION S.R.L. Succursale en France Le Parc Technologique de Lyon 333 Crs du 3ème Millénaire, 69800 Saint Priest - France Tel. +33 4/72476180 Fax +33 4/72470721 info.automation.fr@datalogic.com DATALOGIC AUTOMATION UK Datalogic House Dunstable Road - Redbourn Hertfordshire AL3 7PR - United Kingdom Tel. +44 1582/464900 Fax +44 1582/464999 info.automation.uk@datalogic.com

AMERICA DATALOGIC AUTOMATION INC 3000 Earhart Court, Suite 135 Hebron, Kentucky 41048 United States Tel. +1 859/6897000 Fax +1 859/3344970 info.automation.us@datalogic.com Toll Free Phone +1 800/8495358 Toll Free Fax +1 800/8495357

ASIA DATALOGIC AUTOMATION ASIA LTD Suite 902,Suncome Liauw’s Plaza, 738 Shang Cheng Road, Pudong, Shanghai 200120 , China Tel: +86 21/58366692/3 Fax: +86 )21/58366695 info.automation.cn@datalogic.com DATALOGIC AUTOMATION ASIA LTD Unit 1-3, 7/F, Yuen Long Trading Centre, 33 Wang Yip St. West, Yuen Long, NT. - Hong Kong Tel +852 2785/3912 Fax +852 2785/3913 info.automation.hk@datalogic.com IDEC DATALOGIC.CO.LTD 7-31, Nishi - Miyahara 1 - Chome Yodogawa, Ku Osaka 532004 - Japan Tel. +816 6398/3200 Fax +816 6398/3202 info.automation.jp@datalogic.com

AUSTRALIA - NEW ZEALAND DATALOGIC AUTOMATION PTY LTD Unil 130 - 45 Gilby Road Mount Waverley - Victoria 3149 Australia Tel. +61 3/95589299 Fax +61 3/95589233 info.automation.au@datalogic.com

Product and Company names and logos referenced may be either trademarks or registered trademarks of their respective companies. We reserve the right to make modifications and improvements.

www.automation.datalogic.com www.datasensor.com