The text of a spec sheet · part 6 of 8
Datalogic Automation Sensors Product Guide, pages 51 to 60
Pages 51 to 60 of 80
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Datalogic ED-100
Page 51
Illuminators SIL
SIL
Models
Line - Area - Ring - Spot - Back
Laser
Driver integrated or external integrated power LED
Laser 650 nm
SERIES
Light source Lenses
DATASENSOR Power Optics
Light emission red / green / blue / white / IR red
Emission angles
6° - 25° - 45° - 10x30°
60°
5…24 Vdc
0…30Vdc
Strobe signal Light intensity at 500 mm
250. . .1000 lux
Laser class cl.3
5 mW
TECHNICAL DATA
Power supply Output
Connection
Vdc Vac Vac/dc PNP NPN NPN/PNP relay (triac) other cable connector terminal block
24
5…24
M8 4-poles
M12 4-poles aluminium aluminium
IP65
IP65
Approximate dimensions (mm) Housing material Mechanical protection
49
Page 52
PHOTOELECTRIC DEVICES FOR INSPECTION
Smart Vision Sensors SERIES
SVS1
SVS2
Category
Vision Sensor
Vision Sensor
Resolution
640 x 480
640 x 480
Frame per second up to 60 up to 60
Illuminator integrated integrated
Connectivity configurator connection
Ethernet
RS 232
TECHNICAL DATA
Serial interface Configuration
VSC configurator
PC Graphic user interface
Functioning stand-alone stand-alone
Lenses
6/8/12/16 mm
6/8/12/16 mm
Functions measurement & inspection measurement & inspection or identification
24
24
•
•
2x M12 8-poles
M12 8-poles / M12 4-poles
52 x 58 x 40
52 x 58 x 40 aluminium/plastic aluminium/plastic
IP50
IP50
Power supply Output
Connection Approximate dimensions (mm) Housing material Mechanical protection
50
Vdc Vac Vac/dc PNP NPN NPN/PNP relay (triac) other cable connector terminal block
Page 53
Configurators and Monitors VSC
VSM
Display
3.5“ TFT LCD
3.5“ TFT LCD
Functions
SVS1 sensor setup real time monitoring
SVS2 sensor monitoring
Resolution
320x240
320x240
Mounting
DIN-Rail or panel
DIN-Rail or panel
User interface
8 push-buttons 8 signalling LEDs
8 push-buttons 8 signalling LEDs via SVS1 sensor
24
M12 8-poles n°2 M12 8-poles
96 x 96 x40
96 x 96 x40
Housing material plastic plastic
Mechanical protection
IP40
IP40
SERIES
TECHNICAL DATA
Power supply Output
Connection Approximate dimensions (mm)
Vdc Vac Vac/dc PNP NPN NPN/PNP relay (triac) other cable connector terminal block
51
Page 54
PHOTOELECTRIC DEVICES FOR SAFETY
SE4 series
SE4-R series
SE4T-L series
- 150 to 1650 mm controlled heights - 14, 20, 30, 35 mm resolution and 2, 3, 4 beams - Finger, hand or body protection - Versions with Blanking and EDM functions - Cascade Master/Slave versions and EDM
- 500 mm controlled height - 2 beam model for body protection - Passive unit with mirrors or reflectors - Operating distance up to 7.5 m (linear version) or up to 3 m (‘L’ and ‘T’ versions) - ‘L’ and ‘T’ versions with integrated Muting sensors
- 500 or 800 mm controlled heights - Models with 2 or 3 beams for body protection - Integrated sensor and Muting lamp - ‘L’ (one-way) or ‘T’ (two-way) system - Linear model for external Muting sensors
COMPLETE SERIES
NEW PERFORMANCES
NEW PERFORMANCES
The SE4 series offers the widest range of Type 4 safety light curtains, including standard Base versions and Plus models with Blanking, Master and Slave Cascadable and EDM functions. Models with 150 - 1650 mm controlled heights are available, with 14, 20, 30 or 35 resolution for finger or hand protection and with 2, 3 or 4 beams for body protection. The Restart and Muting configuration is made using dip-switches protected via HW and SW. The Fixed or Floating Blanking function allows to avoid the detection of objects in a fixed position or in a repetitive movement inside the detection area. The Master and Slave versions can be connected in cascade, forming for example vertical and horizzontal ‘L-shaped’ light curtain systems. The EDM controls also the external relay.
The Type 4 retroreflex safety light curtains of the SE4-R series is formed by the active SE4-RA1 unit and by the passive unit with mirrors integrated in the SE4-RDB light curtain or with two SE4-RSM accessory deviating mirrors. The detection height is 500 mm and the operating distance reaches 7.5 m for the linear version or 3 m for the ‘L’ and ‘T’ versions. The Restart, EDM and Muting functions are integrated and selectable through the dipswitches on the active unit. ‘L’ or ‘T’ shaped versions are available for applications requiring the Muting function. The SE4-R light curtains represent a reliable and cost-effective alternative to light curtains with active units on emitter and receiver sides thanks to reduced costs and installation time as well as the advantage of cabling only the active unit.
The Type 4 safety light curtains of the SE4T-L series have the Muting function completely integrated, thanks to the use of pre-assembled, pre-wired and pre-aligned sensors. Models with 'T' integrated Muting sensors for two-way Muting, 'L' integrated Muting sensors for one-way Muting and linear versions without integrated Muting sensors are available. Versions with 2 or 3 safety beams, with 500 and 800 mm. The operating distances reaches 3 m for the ‘T’ and ‘L’ versions using retroreflex arms and 7 m with through beam arms. The linear versions have 25 m operating distances. Integrated Muting lamp and configuration carried-out by dipswitches protected HW and SW distinguish this product series. Muting is necessary when the material has to pass through the dangerous area as for example in palletisers/ depalletisers.
Type 4 SAFEasy™ Base and Plus safety light curtains
52
Type 4 SAFEasy™ Retroreflex safety light curtains
Type 4 SAFEasy™ safety light curtains with SE4 T/L Muting functions
Page 55
SG2 series
SG4 series
- 2 models: BASE and EXTENDED - Resolution 30, 50 and 90 mm - Operating distance up to 19 m and controlled height reaching 1800 mm - Plus functions for EXTENDED models: EDM, Anti-Interference system, selectable Manual/Automatic Restart
- Resolution: 14 and 30 mm - Operating distance reaching 19m (for 30mm versions) and controlled heights reaching 1800 mm - Integrated functions for Type 4 base device: EDM, Manual/Automatic Restart
NEW SERIES
NUOVA SERIE
The new SG2 Type 2 safety light curtains represent the natural evolution of the SF2 series. Two models are available, SG2-B ‘Base’ and SG2-E ’Extended’, in order to guarantee replacement of the SF2 series (SG2-B) and the availability of advanced functions for a Type 2 safety light curtain, such as EDM and Anti-Interference (SG2-E). Other distinctive features include the operating distance reaching 19 m, controlled heights ranging from 150 to 1800 mm, one of the best response times available today, as well as the more functional new profile. The product is also prearranged for the use of new ‘TOPBOTTOM’ rotating fixing brackets that simplify and speed the alignment of the TX and RX units, also at long distances and in applications with deviating mirrors.
The new series of SAFEasyTM SG4-B safety light curtains widens the existing SG range, whilst representing an evolution of the SE4-PLUS line, offering a Type 4 safety light device for finger protection with base functions. Ideal for applications that do not require complementary functions such as Muting, Cascade and blanking. Improved response time and operating distance, respect to the SE4-PLUS series distinguish this series and make it one of the best performing light curtains available today on the market. All models, with heights ranging from 150 to 1800mm, have 14 and 30 mm resolution for finger and hand protection. The EDM function can be easily activated by wire selection, like the Restart function in manual or automation configuration. The 7-segment display helps the user in understanding the diagnostic messages and product alignment.
Type 2 SAFEasy™ safety light curtains with the best performance/cost ratio
Type 4 SAFEasy™ safety light curtains with base functions
53
Page 56
PHOTOELECTRIC DEVICES FOR SAFETY
Selection guide OPERATING PROTECTION POINT SEVERITY OF DAMAGE
LIGHT (normally reversible)
SEVERE (normally irreversible) HAZARD EXPOSURE FREQUENCY AND / OR DURATION
FREQUENT / CONTINUOUS
RARE / SHORT
AVOIDABLE HAZARD
AVOIDABLE HAZARD
NO
YES
YES
NO
TYPE 4
TYPE 2
TYPE 2
SE4-14 SE4-20 SE4-30 SE4-35 SE4-14 PLUS SE4-30 PLUS SG4-B-14 / SG4-B-30
SE2-35 SF2-30 SG2-B-30 / SG2-E-30
SE2-35 SF2-30 SG2-B-30 / SG2-E-30
Note: The given information is indicative and synthetic; it is compulsory to refer to the complete EN 954 standard for a correct risk and safety type evaluation.
RESOLUTION (mm)
OPERATING RANGE (m)
SF2-30
30
15
SG2-B-30
30
19
SG2-E-30
30
9 / 19* * selectable maximum distance: 9 m or 19 m
SE2-35
35
SG4-B-14
14
6
SE4-14
14
6
SE4-14 PLUS
14
6
SE4-20
20
6
SE4-30
30
15
SE4-30 PLUS
30
15
SE4-35
35
15
SG4-B-30
30
19
15
TYPE 2
54
TYPE 4
Page 57
ACCESS PROTECTION SEVERITY OF DAMAGE
LIGHT (normally reversible)
SEVERE (normally irreversible) HAZARD EXPOSURE FREQUENCY AND / OR DURATION
FREQUENT / CONTINUOUS
RARE / SHORT
AVOIDABLE HAZARD
AVOIDABLE HAZARD
NO
YES
YES
NO
TYPE 4
TYPE 2
TYPE 2
SE4-P SE4-Q SE4-L SE4-R SE4-T SE4-S SB-BWS-T4 + Sx-ST4
SE2-P SB-BWS-T2+Sx-ST2 SF2-50 / SF2-90 SG2-B-50/90 / SG2-E-50/90
SE2-P SB-BWS-T2+Sx-ST2 SF2-50 / SF2-90 SG2-B-50/90 / SG2-E-50/90
Note: The given information is indicative and synthetic; it is compulsory to refer to the complete EN 954 standard for a correct risk and safety type evaluation.
SE2-P
RESOLUTION (mm)
OPERATING RANGE (m)
515 - 415 - 315
50
SF2-B-50 / 90
50 / 90
15
SG2-B-50 / 90
50 / 90
19
SG2-E-50 / 90
50 / 90
9 / 19* * selectable maximum distance: 9 m or 19 m
SB-BWS-T2 + SX-ST2 up to 50*
-
* 8 m with S5/S10-ST2; 50 m with S30-ST2
SE4-Q
515 - 415 - 315
SE4-P
515 - 415 - 315
SE4-T
515 - 415
3
SE4-L
515 - 415
3
SE4-S
515 - 415
25 50
25
SE4-R ‘T’
515
3
7
* 3 m for ’-W’ versions; 7 m for ‘-T’ versions
SE4-R ’L’
515
3
7
* 3 m for ’-W’ versions; 7 m for ‘-T’ versions
SE4-R Linear
515
SB-BWS-T4 + Sx-ST4
-
7.5 up to 50* * 8 m with S5/S10-ST4; 40 m with SL5-ST4; 50 m with S30-ST4
TYPE 2
TYPE 4
55
Page 58
PHOTOELECTRIC DEVICES FOR SAFETY
Selection guide Note: The reference Standard is the EN 999 ‘Safety of machinery - the positioning of protective equipment in respect of approach speeds of parts of the human body’. The given information is indicative and synthetic; it is compulsory to refer to the complete EN 999 standard for a correct safety distance calculation. The minimum distance S in mm between the hazardous area and the detection point is expressed by the formula: S = (K x T) + C K is a parameter (mm/sec) linked to the approach speed of the human body or parts T is the total time (sec) necessary to stop the machine, where T = t1 + t2 t1 = max. time between the detection actuation and the change of the device switching status t2 = max. machine response time C is an additional distance (mm) based on the device typology used in terms of resolution, where the resolution is the minimum dimension of an opaque object able to obscure at least one of the beams of the sensitive detection area.
R ≤ 40 mm
Finger or hand protection
R > 70 mm
Body protection
R < 116 mm
Presence detection opaque object
NORMAL APPROACH TO THE DETECTION AREA Safety light curtains with 40 mm maximum resolution S = (K x T) + C where K = 2000 mm/sec, C = 8 (d - 14 mm) but not smaller than 0, d = device resolution (mm) This formula is valid for safety distances S up to 500 mm. If the result of the formula gives S higher than 500 mm, K = 1600 mm/sec and S = (1600 mm/sec x T) + 8(d-14 mm) Safety light curtains with 40 to 70 mm resolution S = (K x T) + C where K = 1600 mm/sec, C = 850 mm In all cases, the highest beam height is ≥ 900 mm and the lowest beam is ≤ 300 mm. Safety light grid with separate multiple beams S = (K x T) + C where K = 1600 mm/sec, C = 850 mm
56
R=resolution
Page 59
A light grid with 2, 3, 4 separate beams is often used to detect the intrusion of the human body or parts in a specific area; the number of beams and the distance between them depends on the risk estimation made and by specific machine applications. Risks such as slipping under the lower beam, passing over the higher beam, passing through two beams have to be considered. The following table provides the heights from the ground or from reference plane for different beams.
Number of beams Heights of single beams from the plane (mm) 4 300, 600, 900, 1200 3 300, 700, 1100 2 400, 900
In case of use of a single beam, in an industrial environment, a height of 750 mm is considered appropriate, with the device positioned at a machine distance, where S = (1600 mm/sec x T) + 1200 mm.
PARALLEL APPROACH TO THE DETECTION AREA S = (K x T) + C where K = 1600 mm/sec, C = (1200 mm - 0,4 H), not less than 850 mm Hmax = 1000 mm, Hmin = 15 (d - 50 mm), where d = resolution of the safety light curtain
ANGLED APPROACH RESPECT TO THE DETECTION AREA For foreseeable approach angles bigger than 30°, follow the normal approach procedure, while for angles inferior to 30° follow the parallel approach procedure.
Note: The reference Standard is the EN 999 ‘Safety of machinery - the positioning of protective equipment in respect of approach speeds of parts of the human body’. The given information is indicative and synthetic; it is compulsory to refer to the complete EN 999 standard for a correct safety distance calculation.
57
Page 60
PHOTOELECTRIC DEVICES FOR SAFETY
TECHNICAL DATA
Finger protection
SERIES
SE4-14
SE4-14 PLUS
According to IEC 61496-1 IEC 61496-2 Power supply
Type 4 integrated light curtains
Type 4 integrated light curtains
24 Vdc
24 Vdc
Resolution
14 mm
14 mm
Operating range
0.2...6 m
0.2...6 m
Controlled height
150...900 mm
150...1200 mm
Response time
18...39 ms
21...68 ms 14...41 ms EDM Models
OSSD output
2 PNP transistor
2 PNP transistor
Connection
Rx: M12 8-poles Tx: M12 4-poles
Rx: M12 8-poles; Tx: M12 4-poles Rx: M12 5-poles; Tx: M12 5-poles
Dimensions (mm)
35 x 40
35 x 40
Device functions
Test Manual/auto Restart selection Total/partial Muting selection Override
Test Manual/auto Restart selection EDM selection
Certifications
Plus functions
58
4 models available: EDM Fixed/Floating Blanking EDM Cascading EDM Cascading/Blanking EDM