Page 51

Illuminators SIL

SIL

Models

Line - Area - Ring - Spot - Back

Laser

Driver integrated or external integrated power LED

Laser 650 nm

SERIES

Light source Lenses

DATASENSOR Power Optics

Light emission red / green / blue / white / IR red

Emission angles

6° - 25° - 45° - 10x30°

60°

5…24 Vdc

0…30Vdc

Strobe signal Light intensity at 500 mm

250. . .1000 lux

Laser class cl.3

5 mW

TECHNICAL DATA

Power supply Output

Connection

Vdc Vac Vac/dc PNP NPN NPN/PNP relay (triac) other cable connector terminal block

24

5…24

M8 4-poles

M12 4-poles aluminium aluminium

IP65

IP65

Approximate dimensions (mm) Housing material Mechanical protection

49

Page 52

PHOTOELECTRIC DEVICES FOR INSPECTION

Smart Vision Sensors SERIES

SVS1

SVS2

Category

Vision Sensor

Vision Sensor

Resolution

640 x 480

640 x 480

Frame per second up to 60 up to 60

Illuminator integrated integrated

Connectivity configurator connection

Ethernet

RS 232

TECHNICAL DATA

Serial interface Configuration

VSC configurator

PC Graphic user interface

Functioning stand-alone stand-alone

Lenses

6/8/12/16 mm

6/8/12/16 mm

Functions measurement & inspection measurement & inspection or identification

24

24

•

•

2x M12 8-poles

M12 8-poles / M12 4-poles

52 x 58 x 40

52 x 58 x 40 aluminium/plastic aluminium/plastic

IP50

IP50

Power supply Output

Connection Approximate dimensions (mm) Housing material Mechanical protection

50

Vdc Vac Vac/dc PNP NPN NPN/PNP relay (triac) other cable connector terminal block

Page 53

Configurators and Monitors VSC

VSM

Display

3.5“ TFT LCD

3.5“ TFT LCD

Functions

SVS1 sensor setup real time monitoring

SVS2 sensor monitoring

Resolution

320x240

320x240

Mounting

DIN-Rail or panel

DIN-Rail or panel

User interface

8 push-buttons 8 signalling LEDs

8 push-buttons 8 signalling LEDs via SVS1 sensor

24

M12 8-poles n°2 M12 8-poles

96 x 96 x40

96 x 96 x40

Housing material plastic plastic

Mechanical protection

IP40

IP40

SERIES

TECHNICAL DATA

Power supply Output

Connection Approximate dimensions (mm)

Vdc Vac Vac/dc PNP NPN NPN/PNP relay (triac) other cable connector terminal block

51

Page 54

PHOTOELECTRIC DEVICES FOR SAFETY

SE4 series

SE4-R series

SE4T-L series

- 150 to 1650 mm controlled heights - 14, 20, 30, 35 mm resolution and 2, 3, 4 beams - Finger, hand or body protection - Versions with Blanking and EDM functions - Cascade Master/Slave versions and EDM

- 500 mm controlled height - 2 beam model for body protection - Passive unit with mirrors or reflectors - Operating distance up to 7.5 m (linear version) or up to 3 m (‘L’ and ‘T’ versions) - ‘L’ and ‘T’ versions with integrated Muting sensors

- 500 or 800 mm controlled heights - Models with 2 or 3 beams for body protection - Integrated sensor and Muting lamp - ‘L’ (one-way) or ‘T’ (two-way) system - Linear model for external Muting sensors

COMPLETE SERIES

NEW PERFORMANCES

NEW PERFORMANCES

The SE4 series offers the widest range of Type 4 safety light curtains, including standard Base versions and Plus models with Blanking, Master and Slave Cascadable and EDM functions. Models with 150 - 1650 mm controlled heights are available, with 14, 20, 30 or 35 resolution for finger or hand protection and with 2, 3 or 4 beams for body protection. The Restart and Muting configuration is made using dip-switches protected via HW and SW. The Fixed or Floating Blanking function allows to avoid the detection of objects in a fixed position or in a repetitive movement inside the detection area. The Master and Slave versions can be connected in cascade, forming for example vertical and horizzontal ‘L-shaped’ light curtain systems. The EDM controls also the external relay.

The Type 4 retroreflex safety light curtains of the SE4-R series is formed by the active SE4-RA1 unit and by the passive unit with mirrors integrated in the SE4-RDB light curtain or with two SE4-RSM accessory deviating mirrors. The detection height is 500 mm and the operating distance reaches 7.5 m for the linear version or 3 m for the ‘L’ and ‘T’ versions. The Restart, EDM and Muting functions are integrated and selectable through the dipswitches on the active unit. ‘L’ or ‘T’ shaped versions are available for applications requiring the Muting function. The SE4-R light curtains represent a reliable and cost-effective alternative to light curtains with active units on emitter and receiver sides thanks to reduced costs and installation time as well as the advantage of cabling only the active unit.

The Type 4 safety light curtains of the SE4T-L series have the Muting function completely integrated, thanks to the use of pre-assembled, pre-wired and pre-aligned sensors. Models with 'T' integrated Muting sensors for two-way Muting, 'L' integrated Muting sensors for one-way Muting and linear versions without integrated Muting sensors are available. Versions with 2 or 3 safety beams, with 500 and 800 mm. The operating distances reaches 3 m for the ‘T’ and ‘L’ versions using retroreflex arms and 7 m with through beam arms. The linear versions have 25 m operating distances. Integrated Muting lamp and configuration carried-out by dipswitches protected HW and SW distinguish this product series. Muting is necessary when the material has to pass through the dangerous area as for example in palletisers/ depalletisers.

Type 4 SAFEasy™ Base and Plus safety light curtains

52

Type 4 SAFEasy™ Retroreflex safety light curtains

Type 4 SAFEasy™ safety light curtains with SE4 T/L Muting functions

Page 55

SG2 series

SG4 series

- 2 models: BASE and EXTENDED - Resolution 30, 50 and 90 mm - Operating distance up to 19 m and controlled height reaching 1800 mm - Plus functions for EXTENDED models: EDM, Anti-Interference system, selectable Manual/Automatic Restart

- Resolution: 14 and 30 mm - Operating distance reaching 19m (for 30mm versions) and controlled heights reaching 1800 mm - Integrated functions for Type 4 base device: EDM, Manual/Automatic Restart

NEW SERIES

NUOVA SERIE

The new SG2 Type 2 safety light curtains represent the natural evolution of the SF2 series. Two models are available, SG2-B ‘Base’ and SG2-E ’Extended’, in order to guarantee replacement of the SF2 series (SG2-B) and the availability of advanced functions for a Type 2 safety light curtain, such as EDM and Anti-Interference (SG2-E). Other distinctive features include the operating distance reaching 19 m, controlled heights ranging from 150 to 1800 mm, one of the best response times available today, as well as the more functional new profile. The product is also prearranged for the use of new ‘TOPBOTTOM’ rotating fixing brackets that simplify and speed the alignment of the TX and RX units, also at long distances and in applications with deviating mirrors.

The new series of SAFEasyTM SG4-B safety light curtains widens the existing SG range, whilst representing an evolution of the SE4-PLUS line, offering a Type 4 safety light device for finger protection with base functions. Ideal for applications that do not require complementary functions such as Muting, Cascade and blanking. Improved response time and operating distance, respect to the SE4-PLUS series distinguish this series and make it one of the best performing light curtains available today on the market. All models, with heights ranging from 150 to 1800mm, have 14 and 30 mm resolution for finger and hand protection. The EDM function can be easily activated by wire selection, like the Restart function in manual or automation configuration. The 7-segment display helps the user in understanding the diagnostic messages and product alignment.

Type 2 SAFEasy™ safety light curtains with the best performance/cost ratio

Type 4 SAFEasy™ safety light curtains with base functions

53

Page 56

PHOTOELECTRIC DEVICES FOR SAFETY

Selection guide OPERATING PROTECTION POINT SEVERITY OF DAMAGE

LIGHT (normally reversible)

SEVERE (normally irreversible) HAZARD EXPOSURE FREQUENCY AND / OR DURATION

FREQUENT / CONTINUOUS

RARE / SHORT

AVOIDABLE HAZARD

AVOIDABLE HAZARD

NO

YES

YES

NO

TYPE 4

TYPE 2

TYPE 2

SE4-14 SE4-20 SE4-30 SE4-35 SE4-14 PLUS SE4-30 PLUS SG4-B-14 / SG4-B-30

SE2-35 SF2-30 SG2-B-30 / SG2-E-30

SE2-35 SF2-30 SG2-B-30 / SG2-E-30

Note: The given information is indicative and synthetic; it is compulsory to refer to the complete EN 954 standard for a correct risk and safety type evaluation.

RESOLUTION (mm)

OPERATING RANGE (m)

SF2-30

30

15

SG2-B-30

30

19

SG2-E-30

30

9 / 19* * selectable maximum distance: 9 m or 19 m

SE2-35

35

SG4-B-14

14

6

SE4-14

14

6

SE4-14 PLUS

14

6

SE4-20

20

6

SE4-30

30

15

SE4-30 PLUS

30

15

SE4-35

35

15

SG4-B-30

30

19

15

TYPE 2

54

TYPE 4

Page 57

ACCESS PROTECTION SEVERITY OF DAMAGE

LIGHT (normally reversible)

SEVERE (normally irreversible) HAZARD EXPOSURE FREQUENCY AND / OR DURATION

FREQUENT / CONTINUOUS

RARE / SHORT

AVOIDABLE HAZARD

AVOIDABLE HAZARD

NO

YES

YES

NO

TYPE 4

TYPE 2

TYPE 2

SE4-P SE4-Q SE4-L SE4-R SE4-T SE4-S SB-BWS-T4 + Sx-ST4

SE2-P SB-BWS-T2+Sx-ST2 SF2-50 / SF2-90 SG2-B-50/90 / SG2-E-50/90

SE2-P SB-BWS-T2+Sx-ST2 SF2-50 / SF2-90 SG2-B-50/90 / SG2-E-50/90

Note: The given information is indicative and synthetic; it is compulsory to refer to the complete EN 954 standard for a correct risk and safety type evaluation.

SE2-P

RESOLUTION (mm)

OPERATING RANGE (m)

515 - 415 - 315

50

SF2-B-50 / 90

50 / 90

15

SG2-B-50 / 90

50 / 90

19

SG2-E-50 / 90

50 / 90

9 / 19* * selectable maximum distance: 9 m or 19 m

SB-BWS-T2 + SX-ST2 up to 50*

-

* 8 m with S5/S10-ST2; 50 m with S30-ST2

SE4-Q

515 - 415 - 315

SE4-P

515 - 415 - 315

SE4-T

515 - 415

3

SE4-L

515 - 415

3

SE4-S

515 - 415

25 50

25

SE4-R ‘T’

515

3

7

* 3 m for ’-W’ versions; 7 m for ‘-T’ versions

SE4-R ’L’

515

3

7

* 3 m for ’-W’ versions; 7 m for ‘-T’ versions

SE4-R Linear

515

SB-BWS-T4 + Sx-ST4

-

7.5 up to 50* * 8 m with S5/S10-ST4; 40 m with SL5-ST4; 50 m with S30-ST4

TYPE 2

TYPE 4

55

Page 58

PHOTOELECTRIC DEVICES FOR SAFETY

Selection guide Note: The reference Standard is the EN 999 ‘Safety of machinery - the positioning of protective equipment in respect of approach speeds of parts of the human body’. The given information is indicative and synthetic; it is compulsory to refer to the complete EN 999 standard for a correct safety distance calculation. The minimum distance S in mm between the hazardous area and the detection point is expressed by the formula: S = (K x T) + C K is a parameter (mm/sec) linked to the approach speed of the human body or parts T is the total time (sec) necessary to stop the machine, where T = t1 + t2 t1 = max. time between the detection actuation and the change of the device switching status t2 = max. machine response time C is an additional distance (mm) based on the device typology used in terms of resolution, where the resolution is the minimum dimension of an opaque object able to obscure at least one of the beams of the sensitive detection area.

R ≤ 40 mm

Finger or hand protection

R > 70 mm

Body protection

R < 116 mm

Presence detection opaque object

NORMAL APPROACH TO THE DETECTION AREA Safety light curtains with 40 mm maximum resolution S = (K x T) + C where K = 2000 mm/sec, C = 8 (d - 14 mm) but not smaller than 0, d = device resolution (mm) This formula is valid for safety distances S up to 500 mm. If the result of the formula gives S higher than 500 mm, K = 1600 mm/sec and S = (1600 mm/sec x T) + 8(d-14 mm) Safety light curtains with 40 to 70 mm resolution S = (K x T) + C where K = 1600 mm/sec, C = 850 mm In all cases, the highest beam height is ≥ 900 mm and the lowest beam is ≤ 300 mm. Safety light grid with separate multiple beams S = (K x T) + C where K = 1600 mm/sec, C = 850 mm

56

R=resolution

Page 59

A light grid with 2, 3, 4 separate beams is often used to detect the intrusion of the human body or parts in a specific area; the number of beams and the distance between them depends on the risk estimation made and by specific machine applications. Risks such as slipping under the lower beam, passing over the higher beam, passing through two beams have to be considered. The following table provides the heights from the ground or from reference plane for different beams.

Number of beams Heights of single beams from the plane (mm) 4 300, 600, 900, 1200 3 300, 700, 1100 2 400, 900

In case of use of a single beam, in an industrial environment, a height of 750 mm is considered appropriate, with the device positioned at a machine distance, where S = (1600 mm/sec x T) + 1200 mm.

PARALLEL APPROACH TO THE DETECTION AREA S = (K x T) + C where K = 1600 mm/sec, C = (1200 mm - 0,4 H), not less than 850 mm Hmax = 1000 mm, Hmin = 15 (d - 50 mm), where d = resolution of the safety light curtain

ANGLED APPROACH RESPECT TO THE DETECTION AREA For foreseeable approach angles bigger than 30°, follow the normal approach procedure, while for angles inferior to 30° follow the parallel approach procedure.

Note: The reference Standard is the EN 999 ‘Safety of machinery - the positioning of protective equipment in respect of approach speeds of parts of the human body’. The given information is indicative and synthetic; it is compulsory to refer to the complete EN 999 standard for a correct safety distance calculation.

57

Page 60

PHOTOELECTRIC DEVICES FOR SAFETY

TECHNICAL DATA

Finger protection

SERIES

SE4-14

SE4-14 PLUS

According to IEC 61496-1 IEC 61496-2 Power supply

Type 4 integrated light curtains

Type 4 integrated light curtains

24 Vdc

24 Vdc

Resolution

14 mm

14 mm

Operating range

0.2...6 m

0.2...6 m

Controlled height

150...900 mm

150...1200 mm

Response time

18...39 ms

21...68 ms 14...41 ms EDM Models

OSSD output

2 PNP transistor

2 PNP transistor

Connection

Rx: M12 8-poles Tx: M12 4-poles

Rx: M12 8-poles; Tx: M12 4-poles Rx: M12 5-poles; Tx: M12 5-poles

Dimensions (mm)

35 x 40

35 x 40

Device functions

Test Manual/auto Restart selection Total/partial Muting selection Override

Test Manual/auto Restart selection EDM selection

Certifications

Plus functions

58

4 models available: EDM Fixed/Floating Blanking EDM Cascading EDM Cascading/Blanking EDM