Filed in the catalog under the Datalogic ED-100

Page 11

S62 series

S90 series

S2Z series

- Sensors with LED or Laser emission - Background suppr. from 3 cm to 2 m - Polarised retroreflex up to 20 m - Distance sensor 50 to 150 mm - NPN/PNP output NO-NC configuration

- Background suppression and polarised retroreflex - Laser class 1 versions for long distances - Contrast and UV lumin. sensors - High mechanical protection degree - Standard 4 wire NO-NC NPN or PNP output

- Base optic functions - IP67 mechanical protection - Timing functions ( ONE-SHOT, ON / OFF Delay) - Connection block with spring clamps to ease cabling

High-performance background suppression and polarised retroreflex

Extended range of compact photoelectric sensors in metal housing

New line of Maxi photoelectric sensors ideal for critical applications

NEW SERIES

NEW PERFORMANCES

NEW SERIES

The S62 series offers the maximum performances in the main optic detection functions. The background suppression models reach a 3-30 cm range with visible red LED emission, or 6-60, 6-120 and 20-200 cm with infrared LED emission. The polarised retroreflex models with visible red LED emission present a very long operating distance reaching 10 m with high immunity against reflection received from shiny objects. Versions with visible red Laser emission are available with both 3-15 or 5-35 cm background suppression and polarised retroreflex up to 22 m and distance measurement 50-150 mm. The Laser sensors are characterised by a very small light spot and a low response time that guarantee excellent detection repeatability.

The S90 series, developed in the sturdy compact 41x49x15 mm metal housing, offers all the application and universal optic functions, available also with Laser class 1 emission. The series includes polarised retroreflex with coaxial optics for the detection of reflective or transparent objects, foreground and background suppression, contrast sensor with white light emission for register mark detection, luminescence sensor with UV emission for fluorescent mark detection. Versions with NPN or PNP output are available with standard M12 connector rotatable in 4 positions.

The new S2Z series offers 4 models with base optic functions: 50 m through beam, 7 m polarised retroreflex, 1 m diffused proximity and 2 m background suppression. Versions with continuous 10 a 30Vdc and alternate 24…240 Vac / 12…240 Vdc free-voltage, available with timing versions, adjustable from 0.1 to 5 seconds. The outputs can have a SPDT relay contact or transistor with double NPN/PNP open collector solution. The connection block facilitates connections and simplifies installation. The sturdy plastic housing guarantees excellent resistance to particularly harsh working environments.

9

Page 12

UNIVERSAL PHOTOELECTRIC SENSORS

Tubular S5

S10

Through beam

0…12 m

0…18 m

Retroreflex (on R2 reflector)

0.1…4 m

0.1…4 m

Polarised retroreflex (on R2 reflector)

0.1…3 m

0.1…3 m

Retroreflex for transparents (on R2 reflector)

0.1…0.8 m

0.1…0.8 m

Diffuse proximity

1…10 cm 1…35 cm 0…60 cm 15 mm

1…10 cm 1…35 cm 0…60 cm 14 mm

OPERATING DISTANCES

SERIES

Fixed focus proximity Background suppression Foreground suppression Distance sensor Through beam with fibre optic

0…85 mm

Diffuse proximity with fibre optic

0…22 mm

TECHNICAL DATA

Power supply Output

Connection

10…30 15…264

10…30

• • • (•)

• •

• •

•

M18 x 55/68

M18 x 55/67

Housing material

ABS

Mechanical protection

IP67

NI plated brass AISI-316L stainless steel IP69K

Approximate dimensions (mm)

10

Vdc Vac Vac/dc PNP NPN NPN/PNP relay (SCR) other cable connector pig-tail

II3

Page 13 read from a scan by OCR; it may hold reading errors

~VDATALOGIC..

DATALOGIC AUTOMATION

0.1...4m

0.1...3m

1...10 cm 1...35 cm

12.30 O@

M18 x 40

ABS

IP69K

Page 14

UNIVERSAL PHOTOELECTRIC SENSORS

OPERATING DISTANCES

Tubular SERIES

S50

Through beam

0…25 m 0…60 m

Retroreflex (on R2 reflector)

0.1…4 m

Polarised retroreflex (on R2 reflector)

0.1…4 m 0.1…16 m

Retroreflex for transparents (on R2 reflector)

0.1…1.3 m

Fixed focus proximity

0…10 cm 0…40 cm 0…70 cm 0…35 cm 10 cm

Background suppression

5…10 cm

Foreground suppression

4…10 cm

Distance sensor

5…10 cm

Through beam with fibre optic

0…100 mm

Diffuse proximity with fibre optic

0…30 mm

Diffuse proximity

TECHNICAL DATA

Power supply Output

10…30

0…20 m cl.1

0.1…4 m

0.1…3 m cl.1

0…10 cm 1…45 cm cl.1

II3

10…30

• •

• •

0…10 V • •

• •

Approximate dimensions (mm)

M18 x 55/68

M18 x 55/68

Housing material

PBT NI plated brass IP67

PBT NI plated brass IP67

Connection

Mechanical protection

12

Vdc Vac Vac/dc PNP NPN NPN/PNP relay (SCR) other cable connector terminal block

S51

Page 15

SDS

SL5 0…60 m cl.1

0.03…12 m cl.1

0…35 cm cl.1

2…10 cm 4…12 cm

10…30

10…30

• •

•

• •

•

M18 x 100 (SDS5) M18 x 80 (SDS10)

M18 x 66

ABS (SDS5) NI plated brass (SDS10) IP67

ABS IP67

13

Page 16

UNIVERSAL PHOTOELECTRIC SENSORS

OPERATING DISTANCES

Miniature and fiber optic SERIES

SMall

S40

Through beam

0…2 m

0.1…6 m

Retroreflex (on R2 reflector)

5…150 cm

0.1…3 m

Polarised retroreflex (on R2 reflector)

10…100 cm

0.1…2.5 m 0.1…6 m

Retroreflex for transparents (on R2 reflector)

0.1…0.7 m

Diffuse proximity

0.5…30 cm 4…15 cm cl.2

1.5…10 cm 2…6 cm cl.2

3…15 mm 3…20 mm 3…30 mm 3…50 mm

Fixed focus proximity Background suppression Foreground suppression Distance sensor Through beam with fibre optic Diffuse proximity with fibre optic

TECHNICAL DATA

Power supply

Vdc Vac Vac/dc PNP NPN NPN/PNP relay other cable connector terminal block

10…30

10…30

• •

• •

•

• •

Approximate dimensions (mm)

8 x 23 x 12

12 x 32 x 20

Housing material polycarbonate

ABS

IP67

IP67

Output

Connection

Mechanical protection

14 cl.2

Page 17 read from a scan by OCR; it may hold reading errors

~VDATALOGIC..

DATALOGIC AUTOMATION

0.1...6 m

0.1...2.5 m

0.1...0.7 m

0.2...35 cm

110 mm

10...20 ® @

12 x 32 x 20

ABS

IP67

Page 18

UNIVERSAL PHOTOELECTRIC SENSORS

OPERATING DISTANCES

Miniature and fiber optic SERIES

S3Z

S3

Through beam

0…15 m

0…5 m

0.1…2.5 m

Retroreflex (on R2 reflector) 0.05…4 m

Polarised retroreflex (on R2 reflector)

0.1…2 m

0.2…0.8 m

Retroreflex for transparents (on R2 reflector) 0…70 cm 5…15 cm

Diffuse proximity

0…10 cm 0…50 cm 12 mm

Fixed focus proximity 5…25 cm

Background suppression Foreground suppression Distance sensor Through beam with fibre optic

0…110 mm

Diffuse proximity with fibre optic

0…33 mm

TECHNICAL DATA

Power supply Output

Connection

10…30

10…30

• •

• •

• •

• •

11 x 31 x 19

13 x 42 x 29

Housing material

PC/PBT

ABS

Mechanical protection

IP67

IP66

Approximate dimensions (mm)

16

Vdc Vac Vac/dc PNP NPN NPN/PNP relay other cable connector pig-tail

Page 19

S8

0…10 m 0.1…5 m

S7 cl.2

0…0.8 m

0…50 cm

2...20 cm 5…30 cm cl.2

12…30

0...300 mm 0...150 mm 0...75 mm 0...100 mm 0...50 mm 0...25 mm 12...24

• •

• •

• •

• • 14 x 42 x 25

10 x 40 x 65

ABS

ABS

IP67

IP65 IP50 (trimmer vers.)

17

Page 20

UNIVERSAL PHOTOELECTRIC SENSORS

OPERATING DISTANCES

Compact SERIES

S6

S60

Through beam

0…20 m

0…20 m 0…60 m cl.1

Retroreflex (on R2 reflector)

0.1…6 m

Polarised retroreflex (on R2 reflector)

0.1…5 m cl.1

Retroreflex for transparents (on R2 reflector)

0.1…1 m

0…3.2 m (coaxial) 0.1…6.5 m 0.1…20 m 0…1.7 m (coaxial)

Diffuse proximity

1…90 cm 5…200 cm

1…100 cm 5…200 cm 0…60 cm

Background suppression

0.1…10 cm 3…25 cm 10…50 cm

7…20 cm 5…10 cm

Foreground suppression

5…20 cm

7…20 cm cl.1

Fixed focus proximity

Distance sensor

5…15 cm

Through beam with fibre optic Diffuse proximity with fibre optic

TECHNICAL DATA

Power supply Output

10…30 15…264 •

10…30

• •

• • • •

0…10 V • •

18 x 50 x 50

15 x 50 x 50

Housing material

ABS

ABS

Mechanical protection

IP65

IP67

Connection Approximate dimensions (mm)

18

Vdc Vac Vac/dc PNP NPN NPN/PNP relay other cable connector terminal block cl.1