The text of a manual · part 8 of 9
DS4600A Reference Manual, pages 52 to 55
Pages 52 to 55 of 63: MAINTENANCE; TROUBLESHOOTING
The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DS-4600A
Page 52
DS4600A
4
4
MAINTENANCE
4.1
CLEANING
Clean the laser beam output window periodically for continued correct operation of the reader. Dust, dirt, etc. on the window may alter the reading performance. Repeat the operation frequently in particularly dirty environments. Use soft material and alcohol to clean the window and avoid any abrasive substances.
Clean the window of the DS4600A when the scanner is turned off or, at least, when the laser beam is deactivated. WARNING
40
Page 53
TROUBLESHOOTING
5
TROUBLESHOOTING
5.1
GENERAL GUIDELINES
5
When wiring the device, pay careful attention to the pin number of the signals and whether you are referring to the scanner connector or to the C-BOX 100 spring clamp connectors. If you need information about a certain reader parameter you can refer to the WinHostprogram help files. Either connect the device and select the parameter you’re interested in by pressing the F1 key, or select Help/Contents/DS4600A Configuration from the command menu. If you’re unable to fix the problem and you’re going to contact your local Datalogic office or Datalogic Partner or ARC, we suggest providing (if possible) the Device Configuration files (*.cfg). Connect through WinHostand click the Save icon from the edit configuration window. Also note the exact Model, Serial Number and Order Number of the device.
41
Page 54
DS4600A
5 TROUBLESHOOTING GUIDE Problem Power On: the “Power On”/”Ready” LED is not lit
Suggestions Is power connected? If using a power adapter (like PG 220), is it connected to a wall outlet? If using rail power, does rail have power? If using C-Box 100, does it have power (check switch and LED)? Measure voltage either at pin 13 and pin 25 (for 25-pin connector) or at spring clamp 1 and 2 (for C-BOX 100).
On line Mode: EXT TRIGGER LED is not lit (when external trigger activates)
Is sensor connected to EXT TRIG pins (18 and 19 for 25pin connector)? Is power supplied to photo sensor? Is power supplied to EXT TRIG+ (NPN output)? Is EXT TRIG- grounded (PNP output)? Is the correct polarity observed (current flowing from EXT TRIG+ to EXT TRIG-)? Are the photo sensor LEDS (if any) working correctly? Is the sensor/reflector system aligned?
On line Mode: EXT TRIGGER LED is correctly lit but nothing happens (no reading results) Serial On line Mode: the reader is not triggered (no reading results)
Is the software configuration consistent with the application condition (operating mode etc.)? In the WinHost program select the OPERATING MODE tab and check for related parameters
On line Mode and Serial On Line: Reader doesn’t respond correctly to the expected external signals end
42
In the WinHost program select the OPERATING MODE tab and check if serial on line is enabled as operating mode Are the Start – Stop characters correctly assigned? Is the serial trigger source correctly connected and configured? In the WinHost program select the OPERATING MODE tab and check the TIMEOUT parameterization.
Page 55
TROUBLESHOOTING
5 TROUBLESHOOTING GUIDE
Problem Reading: Not possible to read the target barcode (always returns No Read)
Suggestions Check synchronization of reading pulse with object to read Is the scan line correctly positioned? Place barcode in the center of scan line and run TEST MODE (selectable by WinHost as an Operating Mode). If you still have trouble, check the following: • Is the reading distance within that allowed (see reading diagrams)? • Is the Tilt angle too large? • Is the Skew angle less than 10° (direct reflection)? • Choose the CODE tab and enable different code types (except Pharmacode). LENGTH = Variable • Is the Bar Code quality sufficient? If you had no success, try to perform the test using the BARCODE TEST CHART included with the product.
Communication: Device is not transmitting anything to the host
• • • •
Communication: Data transferred to the host are incorrect, corrupted or incomplete
•
Communication: Always returns the Reader Failure Character (<BEL> char as default) How do I obtain my units’ serial numbers?
•
• •
• • •
Is the serial cable connected? Is the correct wiring respected? Are serial host settings equivalent to the serial device setting? If using C-BOX 100, be sure the RS485 termination switch is positioned to OFF. In the WinHost program select the DATA FORMAT tab and check for values of HEADER, TERMINATOR, SEPARATOR, FILL CHARACTERS Also check the CODE FIELD LENGTH value Are the COM port parameters correctly assigned? Contact your local Datalogic office or Datalogic Partner or ARC, because either a Motor or Laser failure has occurred. Note the exact model and Serial Number of the device The device’s serial number is printed on a label that is affixed to the body of the reader. Serial numbers consist of 9 characters: one letter, 2 numbers, and another letter followed by 5 numbers.
43