For the Datalogic DS-4600A

Page 1

DS4600A QUICK GUIDE

General View:

Laser Safety: 12

The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations. For installation, use and maintenance it is not necessary to open the device.

1

11

2

DS4600A - 2XXX Models

4

5

3

There is a safety device which allows the laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed. The laser beam can be switched off through a software command (see also the WinHost Help On-Line). AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS APERTURE

6 7

10 9

2

8

CAUTION-CLASS 3B LASER LIGHT WHEN OPEN AVOID EXPOSURE TO BEAM

DS4600A - 3XXX Models Figure A

DATALOGIC S.p.A. Via Candini, 2 40012 LIPPO DI CALDERARA (BO) ITALY Model No.

Serial No.

1 Cable with 25-pin Connector

7 External Trigger LED

Volt

Amp.

2 Laser Beam Output Window

8 Good Read LED

Manufactured

3 Accessory Mounting Holes

9 Ready LED

This product conforms to the applicable requirements of 21CFR1040 at the date of manufacture.

4 Warning Label

10 Warning and Classification Labels

5 Mounting Holes

11 Keypad

6 Data TX LED

12 Display

LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAXIMUM OUTPUT RADIATION 1 mW EMITTED WAVE LENGTH 630~680 nm TO EN 60825-1 (2001)

For further details on product installation, see the complete Installation Manual available on the WinHost CD included with this product.

Power Supply: - This product is intended to be installed by Qualified Personnel only. - Models DS4600A-XXX0: This device is intended to be supplied by a UL Listed Direct Plug-in Power Unit marked “Class 2”, rated 10-30 V minimum, 0.60 A. This device may also be supplied by a UL Listed Power Unit marked “Class 2” or LPS power source which supplies power directly to the scanner via the 25-pin connector. - Model DS4600A-2XX5: This device is intended to be supplied by a UL Listed Direct Plug-in Power Unit marked “Class 2”, rated 24 V minimum, 0.50 A. This device may also be supplied by a UL Listed Power Unit marked “Class 2” or LPS power source which supplies power directly to the scanner via the 25-pin connector.

WEEE Compliance:

Warning and device class labels

The laser diode used in this device is classified as a class 3B laser product according to EN 60825-1 regulations and as a Class IIIb laser product according to CDRH regulations. As it is not possible to apply a classification label on the laser diode used in this device, the following label is reproduced below.

LASER LIGHT AVOID EXPOSURE TO BEAM CLASS 3B LASER PRODUCT MAX. OUTPUT RADIATION 30 mW EMITTED WAVE LENGTH 630~680 nm TO EN 60825-1 (2001)

Laser diode class label

Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode (30 mW at 630 to 680 nm).

Page 2

DS4600A QUICK GUIDE

Model Description: DS4600A - X X X X Decoding Mode 2 = Standard w/ Display 3 = Advanced Code Reconstruction

Reading Range 0 = Medium Range 1 = Long Range 2 = Short Range

Optic Version 0 = Linear 1 = Raster R1 2 = Raster R2

Special Features 0 = Standard 5 = Integrated Heater

The following table displays each version’s reading performance. Version

Reading Distance

210X 200X 220X 310X 300X 320X

200 mm (8 in) - 980 mm (39 in) on 1.00 mm (40 mils) codes 160 mm (6 in) - 540 mm (21 in) on 0.50 mm (20 mils) codes 50 mm (1.97 in) - 400 mm (15.75 in) on 0.80 mm (31 mils) codes 200 mm (8 in) - 970 mm (38 in) on 1.00 mm (40 mils) codes 160 mm (6 in) - 540 mm (21 in) on 0.50 mm (20 mils) codes 120 mm (4.7 in) - 310 mm (12.2 in) on 0.30 mm (12 mils) codes

Max Code Resolution

Speed mm (mils)

scans/s

0.50 (20) 0.25 (10) 0.20 (8) 0.50 (20) 0.25 (10) 0.20 (8)

800 800 800 800 800 800

Technical Features: ELECTRICAL FEATURES Power Supply Model XXX0: 10 –30 Vdc Model 2XX5: 24 Vdc Power Consumption Model XXX0: 6W max. Model 2XX5: 12W Main Serial Interface RS232; RS485 Full-Duplex RS485 Half-Duplex Auxiliary Interface Baudrates Inputs External Trigger, IN1, IN2 Voltage max. Current Consumption max. Outputs

RS232 1200 to 115200

OUT1, OUT2 VCE max.

(optocoupled OE or OC) 40 Vdc

Collector Current max. VCE Saturation

40 mA continuous; 130 mA pulsed 1V at 10 mA max.

Power Dissipation max. OPTICAL FEATURES Light Source Wavelength Safety Class USER INTERFACE LED Indicators

90 mW at 40 °C (Ambient temp.)

(optocoupled NPN or PNP) 30 Vdc 25 mA

Headers and Terminators

Up to four header and four terminator characters

Operating Modes

On-Line, Automatic, Serial-On-Line, Test Through menus using WinHost utility Host Mode (commands from one of the serial ports) Up to six different codes during one reading phase Non-volatile internal EEPROM

Configuration Modes

Semiconductor laser diode 630 to 680 nm Class 2 - EN 60825-1; CDRH Ready, Good Read, External Trigger, Data TX

PHYSICAL FEATURES Dimensions 101x84x42 mm (4x3.3x1.7 in) Weight 615 g. (22 oz)

2

SOFTWARE FEATURES Readable Codes EAN/UPC (including Add-on 2 and Add-on 5) Code 39 2/5 Interleaved Code 128 EAN 128 Code 93 Codabar Pharmacode

Code Selection Parameter Storage

ENVIRONMENTAL FEATURES Operating 0° to 40 °C (32° to 104 °F) Temperature 2XX5: -30° (-22 °F) to 40 °C Storage -20° to 70 °C (-4° to 158 °F) Temperature Humidity max 90% non condensing Vibration Resistance 14 mm @ 2 to 10 Hz IEC 68-2-6 test FC 1.5 mm @ 13 to 55 Hz 2 g @ 70 to 200 Hz 2 hours on each axis Shock Resistance 30g; 11 ms; IEC 68-2-27 test EA 3 shocks on each axis Protection Class IP65

Page 3

DS4600A QUICK GUIDE

Accessories: Name C-BOX 100/200 C-BOX 300/310 C-BOX 400/410 GFC-41 OM4000 INT-30 (for C-Box 100)

Description Connection Box Connection Box Profibus Connection Box DeviceNet 90° Reading Device Oscillating Mirror 20 mA Current Loop Interface Board

Part Number 93ACC1510, 93ACC1520 93A301000, 93A301030 93A301010, 93A301040 91D081000 93A251030 93A151022

Electrical Connections: DS4600A is equipped with a cable terminated by a 25-pin female D-sub connector for connection to the power supply and input/output signals.

CAUTION

Do not connect GND and SGNDs (Main or Aux) to different (external) ground references. GND and SGNDs (Main and Aux) are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.

The details of the connector pins are indicated in the following table: 25-pin D-sub female connector pinout Pin

Name

Function

13 25 1 9 18 19 6 10 14 15 8 22 11 12 20 21 23 24 16 17

VS GND CHASSIS VS EXT TRIG+ EXT TRIGIN1+ IN1IN2+ IN2OUT1 + OUT1OUT2 + OUT2RXAUX TXAUX SGND Aux GND Reserved Reserved

Power supply input voltage + Power supply input voltage Chassis Ground External Trigger supply voltage + External Trigger + External Trigger Input 1 + Input 1 Input 2 + Input 2 Output 1 + Output 1 Output 2 + Output 2 Auxiliary RS232 Auxiliary RS232 Signal Ground Auxiliary interface Power Supply Voltage -

Pin 2 3 4 5 7

RS232 TX232 RX232 RTS232 CTS232 SGND Main

25-pin female connector

RS485 Full-Duplex TX485+ RX485+ TX485RX485SGND Main

RS485 Half-Duplex RTX485+ RTX485SGND Main

3

Page 4

DS4600A QUICK GUIDE

20 0.79

18* 20.2

83.5 3.29

0.71

0.8

14.8 0.58 M4 N°2

101

3.98

39.4 1.55

83.5 3.29

58 2.28

37 1.46

101

3.98

58 2.28

37 1.46

87.9 3.46

81 3.19

39.4 1.55

10 0.39

22* 0.86 20.2 14.8 0.58 0.8 M4 N°2

8.25 0.32

41.8 1.64

20 0.79

Mechanical Installation:

5 0.2

Mounting hole depth M4 X 5

3.75 0.15

23 0.90

42 1.65

18 0.70

3.75 0.15 37 1.47

32.5 1.28

DS4600A

18 0.70

11.8 0.46

32.5 1.28

M4 N° 4

23 0.90

42 1.65

* The quote refers to the scan line

* The quote refers to the scan line Overall dimensions for 3XXX Models

5.5 0.22

Overall dimensions for 2XXX Models

115 4.53

Input/Output Connections: Open Collector

C

Vext 40 Vdc max.

USER INTERFACE

8/11

+

12/22

-

5.5 0.22

DS4600A 25-pin

10°

57.3 2.26 5 0.20

5 5. 2 2 0.

39 1.54

35°

5.5 0.22

E

3 0.12

Output open collector connections VCE max = 40 Vdc

Mounting Bracket Dimensions

I max = 40 mA continuous NPN Vext 30 Vdc max. USER INTERFACE

DS4600A 25-pin + 5V

NPN

18/6/14

+

19/10/15

-

DS4600A 25-pin

USER INTERFACE 9

VS

18/6/14

+

19/10/15

-

25

GND

V

+ 5V

V

Signal

Input NPN command using external power

Input NPN command using DS4600A power PNP

PNP DS4600A 25-pin

Vext 30 Vdc max.

USER INTERFACE V

+

19/10/15

-

Signal

Ground

Input PNP command using external power

4

USER INTERFACE

DS4600A 25-pin 9

VS

18/6/14

+

19/10/15

-

25

GND

V

+ 5V

+ 5V 18/6/14

Signal Ground

Signal

Ground

Input PNP command using DS4600A power

Page 5

DS4600A QUICK GUIDE

Connectivity: Point-to-point layout c Main Serial Interface dAuxiliary Serial Interface (Local Echo) (RS232) eExternal Trigger (for On-Line Mode)

Pass-through layout c Main Serial Interface (RS232) dAuxiliary Serial Interface (RS232) eExternal Trigger (for On-Line Mode)

RS232 Master/slave layout c Main Serial Interface (Slaves RS232 only) dAuxiliary Serial Interface (RS232) eExternal Trigger (for On-Line Mode)

Multiplexer layout c Main Serial Interface (RS485 Half-Duplex) dAuxiliary Serial Interface (Local Echo) (RS232) eExternal Trigger (for On-Line Mode)

RS485 Master/slave layout c Auxiliary Serial Interface (RS232) d Main Serial Interface (RS485 Half-Duplex) eExternal Trigger

5

Page 6

DS4600A QUICK GUIDE

Reading Diagrams: DS4600A-210X (Long Range) 0

4

40

(in)

0

100 200 300 400 500 600 700 800 900 1000

(mm)

8

12

16

20

24

28

32

36

16 400 CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 15° Tilt angle = 0° *Code Resolution: Standard - for 0.50 mm (20 mils) codes and greater *Code Reading Condition: Standard * Parameter selectable in WinHost.

12 300 8

200

4

100

0.50 mm (20 mils) 0.60 mm (24 mils) 0.80 mm (31 mils) 1.00 mm (40 mils)

0 -4 -100 -8 -200 -12 -300 -16 -400 (in) (mm)

DS4600A-200X (Medium Range)

CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 15° Tilt angle = 0° *Code Resolution: High - for 0.30 mm (12 mils) codes and smaller Standard - for 0.50 mm (20 mils) codes and greater *Code Reading Condition: Standard * Parameter selectable in WinHost.

0

2

22

(in)

0

50 100 150 200 250 300 350 400 450 500 550

(mm)

10

250

8

200

6

150

4

100

2

50

0

0

-2

-50

-4 -100 -6 -150 -8 -200 -10 -250 (in) (mm)

6

4

6

8

10

12

14

16

18

20

0.30 mm (12 mils) 0.50 mm (20 mils)