Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 5 of 5

DL910 Series Instruction Manual, pages 37 to 42

Pages 37 to 42 of 42

The original document is the PDF (503 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic DL910

Page 37 read from a scan by OCR; it may hold reading errors

OPEN THIS PAGE TO READ THE DESIRED CHARACTER / NUMBER SELECTIONS

( LD TiO

Page 38

DL910 SERIES

DATALOGIC

This page is intentionally left blank. 2.28 - Configuration

Page 39

DATALOGIC

DL910 SERIES

3. MAINTENANCE AND TROUBLESHOOTING 3.1 MAINTENANCE The DL910 series rugged and reliable scanner is protected against dust and liquids and normal maintenance is not required. The only precaution necessary to maintain good quality reading is to always keep the laser beam output window clean. Therefore avoid touching the window with the fingers or abrasive materials. Clean the window with an air jet or if this is not sufficient, with alcohol and a soft cloth. A dirty output window slows down the reading time and can eventually prevent the scanner from reading at all.

3.2 TROUBLESHOOTING •

The reader does not emit any acoustic signal at power on.

Every model, except for PEN EMULATION, should audibly signal the correct completion of the auto test procedure. Verify that the connector is correctly fixed. Return the device to the nearest DATALOGIC center if the trouble persists. •

The reader emits a continual acoustic signal at power on.

The internal memory check (ROM/RAM/EEPROM) gave negative results. Return the device to the nearest DATALOGIC center. •

The reader does not read codes or reads with difficulty a - verify that the code to read is among those selected and the label is not damaged. b - verify the good reading using the DATALOGIC test chart, clean the window if necessary. c - return the device to the nearest DATALOGIC center if the trouble persists after these controls.

Maintenance and troubleshooting - 3.1

Page 40

DL910 SERIES

DATALOGIC

This page is intentionally left blank.

3.2 - Maintenance and troubleshooting

Page 41

DATALOGIC

DL910 SERIES

4. TECHNICAL FEATURES HARDWARE FEATURES Power supply

4.75 to 14 VDC

Consumption

Depends on the model: refer to the relative appendix. 36 scans/sec. ± 3

Scan rate Max. resolution

0.13 mm

Laser class: EN60825-1,CDRH

Class 2

ENVIRONMENTAL FEATURES Weight Operating temperature Storage temperature

420 g -10 to +40 °C 14 to +104 °F -20 to + 60 °C -4 to +140 °F

Maximum relative humidity

95% non condensing

Protection class

IP64

Resistance to falls

IEC 68-2-32 Test ED

ESD immunity

15 KV R = 150Ω C = 150 pF

Technical features - 4.1

Page 42

DL910 SERIES

DATALOGIC

SOFTWARE FEATURES Configuration methods

"Barcode menu configuration", reading labels in the Operator’s manuals. "Copy configuration" procedure with another DL910 reader. “Automatic configuration” reading customised labels

Retention of Using an internal non volatile programming data EEPROM memory Code selection EAN/UPC family with & without ADD ON CODE 39 (normal & FULL ASCII) CODE 32 (Italian pharmaceutical) C.I.P. /39 (French pharmaceutical) C.I.P./HR (French pharmaceutical) CODABAR ABC CODABAR INTERLEAVED 2/5 NORMAL 2/5 (5 bars) INDUSTRIAL 2/5 (IATA) MATRIX 2/5 (3 bars) CODE 93 CODE 11 CODE 128 MSI CODE PLESSEY CODE TELEPEN CODE IBM DELTA EAN 128 Selection mode Single or autodiscrimination of up to 5 codes, various options can be enabled for each code. Decoding safety up to 4 "good" consecutive and equal decodes on the same user programmable code.

Reading mode

Manual using On/off button.

4.2 - Technical features