Page 32

DATALOGIC SKORPIO™/ SKORPIO-GUN™

2

2

CONNECTIONS

2.1

USB CONNECTION

You can use a standard mini USB cable to connect the Datalogic Skorpio™ to a host computer to transfer data. A

B C

Key: A Host computer B Datalogic Skorpio™

CAUTION

C 94A051016 (Standard Mini USB cable)

The application of an ESD near the communication/charger pins during the USB active sync connection to an host system could result in an interruption of the link. Disconnect and insert again the Mini USB jack in order to reactivate the connection.

For USB communication using the Datalogic Skorpio™ Single Cradle Desk or the Datalogic Skorpio™ Single Cradle Ethernet, connect the cradle to the host by means of any USB straight cord, such as Datalogic CAB-381 cable. Insert the power supply plug into the power jack on the back of the cradle and attach the power supply to a power outlet. Once the host has been turned on, insert the Datalogic Skorpio™ mobile computer into the cradle.

12

Page 33

CONNECTIONS

2

A B C

D Key: A

Host computer

C

B

94A051017 CAB-381 USB type A-B Straight Cable

D

Datalogic Skorpio™ Single Cradle Desk/ Datalogic Skorpio™ SIngle Cradle Ethernet Power Supply*

* Recommended Power Supply: FPS18 AC/DC Power Supply (94ACC4595).

2.2

CONNECTION TO USB PERIPHERALS

You can use a standard A (4 pin female) to mini A (5 pin male) USB cable to connect the Datalogic Skorpio™ to a keyboard or a memory. For all these devices maximum current withdrawal must be below 100mA.

A

B C

Key: A Keyboard with USB interface

C 94A051024 (Standard A to Mini A USB cable)

B Datalogic Skorpio™

13

Page 34

DATALOGIC SKORPIO™/ SKORPIO-GUN™

2

A

B C

Key: A Memory with USB interface

C 94A051024 (Standard A to Mini A USB cable)

B Datalogic Skorpio™ Datalogic Skorpio™ works with most of mentioned USB peripherals. In any case, we can’t guarantee good operations with all devices available on market place. NOTE

2.3

RS232 CONNECTION

The Datalogic Skorpio Single Cradle Desk, the Datalogic Skorpio Single Cradle Modem and the Datalogic Skorpio/F-Color Multiple Cradle can be connected to the Host by cable 94A054000 for 9-pin connections. The RJ45 connector of the desired cable must be connected to the RS232 port of the cradle. Insert the power supply plug into the power jack on the base of the cradle and attach the power supply to a power outlet. Once the Host has been turned on, insert the Datalogic Skorpio-GUN™ terminal into the cradle.

14

Page 35

CONNECTIONS

2

Key: A) Host computer B) 94A054000 9-pin serial cable

C) Datalogic Skorpio™ Single Cradle Desk or Datalogic Skorpio Single Cradle Modem or Datalogic Skorpio/F-Color Multiple Cradle D) Power Supply*

* Recommended Power Supply: FPS18 AC/DC Power Supply (94ACC4595).

CAUTION

If the mobile computer supports Windows Mobile, before plugging the RS232 cable you have to check the 'COM1 Enable' option on the 'System Configuration' window. (Start -> Programs -> System Configuration).

15

Page 36

DATALOGIC SKORPIO™/ SKORPIO-GUN™

2

2.4

MODEM CONNECTION

The Datalogic Skorpio™ Single Cradle Modem has an integrated modem and provides a modem connector, which can be used with an RJ11 connector. It can be connected to a telephone line to transfer data to a Host. A B C Key: A) Datalogic Skorpio™ Single Cradle Modem B) Phone line to remote Hos

C) Power Supply*

* Recommended Power Supply: FPS18 AC/DC Power Supply (94ACC4595).

It is mandatory to use an appropriate custom software application that calls the DLDEVICE_SetCradleModem function in the SDK in order to use the cradle integrated modem port. Refer to the Datalogic Skorpio™ Single Cradle Modem instructions for further details.

2.5

ETHERNET CONNECTION

The Datalogic Skorpio™ Single Cradle Ethernet and the Datalogic Skorpio™ Ethernet Multi Cradle provide an Ethernet connection. Connect the Ethernet cradle to an Ethernet hub or switch. Connect the power jack to power supply*. A

B C Key: A) Datalogic Skorpio™ Single Cradle Ethernet/ Datalogic Skorpio™ Ethernet Multi Cradle B) Ethernet hub

C) Power Supply*

* Recommended Power Supply: FPS18 AC/DC Power Supply (94ACC4595).

Refer to the Datalogic Skorpio™ Single Cradle Ethernet or to the Datalogic Skorpio™ Ethernet Multi Cradle instructions for further details.

16

Page 37

CONNECTIONS

2.6

2

WPAN CONNECTIONS

Datalogic Skorpio™ Bluetooth® models can communicate with a Bluetooth® device, ® such as a printer, within a range of 10 m, using the on-board Bluetooth module.

A

B

Key: A) Datalogic Skorpio™ ® B) Bluetooth printer

NOTE

In order to avoid wasting energy, the Bluetooth® module is off by default. If you need to have Bluetooth® working, the module must be powered on using the Wireless Communications applet (see par. 3.8.4), and perform the Discovery procedure (see par. 3.9.3).

NOTE

Suspending the terminal powers off the Bluetooth® radio and drops the piconet (Bluetooth® connection). When the terminal resumes, it ® takes approximately 10 seconds for the Bluetooth radio driver to reinitialize the radio.

Area coverage and Bluetooth® radio performance may vary, due to environmental conditions or interference caused by other devices (microwave ovens, radio transmitters, etc.), etc. NOTE

17

Page 38

DATALOGIC SKORPIO™/ SKORPIO-GUN™

2

2.7

WLAN CONNECTION

Datalogic Skorpio™ IEEE 802.11b and IEEE 802.11b/g models can communicate with the host using the on-board radio frequency module and an Access Point connected to the host computer. For the 7xx-xxx-xxx radio models, you can find information about the applet for radio configuration: http://www.summitdatacom.com/SCU.htm. To launch this utility you can tap the specific icon if it's visible on the taskbar or: 1. On Windows CE devices, you can open Connections folder or Control Panel from desktop and select the 'Summit Client Utility' icon. 2. On Windows Mobile devices, you can select the menu item: Start->Programs>Summit and tap the ‘Summit Client Utility’ icon.

A

B

C

Key: A) Datalogic Skorpio™ B) Access point C) Host – Application Server

18

Page 39

CONNECTIONS

2

WLAN module is on by default, in order to avoid wasting energy, you can switch it off using the Wireless Communications applet. NOTE

NOTE

Suspending the terminal powers off the 802.11b/g radio and drops the radio connection. When the terminal resumes, depending on the radio power mode and security protocol selected, it takes approximately from 10 to 30 seconds for the 802.11b/g radio driver to re-associate the radio to the network.

Area coverage and radio performance may vary, due to environmental conditions, access points types or interference caused by other devices (microwave ovens, radio transmitters, etc.) NOTE

19

Page 40

DATALOGIC SKORPIO™/ SKORPIO-GUN™

2

2.8

WIRELESS AND RADIO FREQUENCIES WARNINGS

Use only the supplied or an approved replacement antenna. Unauthorized antennas, modifications or attachments could damage the product and may violate laws and regulations. WARNING

Most modern electronic equipment is shielded from RF signals. However, certain electronic equipment may not be shielded against the RF signals generated by Datalogic Joya™ and I7252™. WARNING

WARNING

Datalogic recommends persons with pacemakers or other medical devices to follow the same recommendations provided by Health Industry Manufacturers Associations for mobile phones. Persons with pacemakers: • Should ALWAYS keep this device more than twenty five (25) cm from their pacemaker and/or any other medical device; • Should not carry this device in a breast pocket; • Should keep the device at the opposite side of the pacemaker and/or any other medical device; • Should turn this device OFF or move it immediately AWAY if there is any reason to suspect that interference is taking place. • Should ALWAYS read pacemaker or any other medical device guides or should consult the manufacturer of the medical device to determine if it is adequately shielded from external RF energy. In case of doubt concerning the use of wireless devices with an implanted medical device, contact your doctor.

Turn this device OFF in health care facilities when any regulations posted in these areas instruct you to do so. Hospitals or health care facilities may use equipment that could be sensitive to external RF energy. WARNING

20

Page 41

CONNECTIONS

2

WARNING

RF signals may affect improperly installed or inadequately shielded electronic systems in motor vehicles. Check with the manufacturer or its representative regarding your vehicle. You should also consult the manufacturer of any equipment that has been added to your vehicle.

WARNING

An air bag inflates with great force. DO NOT place objects, including either installed or portable wireless equipment, in the area over the air bag or in the air bag deployment area. If vehicle’s wireless equipment is improperly installed and the air bag inflates, serious injury could result.

WARNING

Turn off the device when in any area with a potentially explosive atmosphere. Observe restrictions and follow closely any laws, regulations, warnings and best practices on the use of radio equipment near fuel storage areas or distribution fuel areas, chemical plants or where some operation involves use of explosive materials. Do not store or carry flammable liquids, explosive gases or materials with the device or its parts or accessories. Areas with a potentially explosive atmosphere are often, but not always, clearly marked or showed. Sparks in such areas could cause an explosion or fire, resulting in injury or even death.

21