Page 30

KYMAN™

2

2

CONNECTIONS

2.1

RS232/USB DIRECT CONNECTION

You can use a cable to connect the Kyman™ to a host computer to transfer data.

Key: A B

Host computer Kyman™

C

RS232 cable or USB cable

Host computer Kyman™

C D

RS232 cable or USB cable Power Supply*

Key: A B

* Recommended Power Supply: FPS18 AC/DC Power Supply (94ACC4595).

CAUTION

CAUTION

12

If the PDA supports Windows Mobile, before plugging the RS232 cable you have to check the 'COM1 Enable' option on the 'System Configuration' window. (Start -> Programs -> System Configuration). USB communication may not be completely guaranteed while batteries are simultaneously in charge. Avoid the power supply connection when the USB link is active.

Page 31

CONNECTIONS

2.2

2

WLAN CONNECTION

Kyman™ Wi-Fi 802.11b and Wi-Fi 802.11b/g1 models can communicate with the host using the on-board radio frequency module and an Access Point connected to the host computer. For models using the WiFi7 radio (7xx-xxx-xxx models), you can find information about the applet for radio configuration: http://www.summitdatacom.com/SCU.htm. To launch this utility you can tap the specific icon if it’s visible on the taskbar or: 1. On Windows CE device, you can open Connections folder or Control Panel from desktop and select the ‘Summit Client Utility’ icon. 2. On Windows Mobile device, you can select the menu item: Start->Programs>Summit and tap the ‘Summit Client Utility’ icon.

A

B

C

Key: A) Kyman™ B) Access point C) Host – Application Server 1

Note: unless otherwise specified, the Wi-Fi term is used both for the 802.11b and the 802.11b/g cards.

13

Page 32

2

NOTE

NOTE

NOTE

14

KYMAN™

Wi-Fi module is on by default. In order to avoid wasting energy, you can switch it off using the Wireless Communications applet (see par. 3.8.4). To start configuring your WLAN connection, tap the Wi-Fi icon at the bottom of the screen. Suspending the terminal powers off the 802.11b/g radio and drops the radio connection. When the terminal resumes, depending on the radio power mode and security protocol selected, it takes approximately from 10 to 30 seconds for the 802.11b/g radio driver to re-associate the radio to the network.

Area coverage and radio performance may vary, due to environmental conditions, access points types or interference caused by other devices (microwave ovens, radio transmitters, etc.).

Page 33

CONNECTIONS

2.3

2

WPAN CONNECTIONS

Kyman™ mobile computers can communicate with a Bluetooth® device, such as a ® printer, within a range of 10 m, using the on-board Bluetooth module.

A

Key: A) B)

NOTE

NOTE

NOTE

B

Kyman™ ® Bluetooth printer In order to avoid wasting energy, the Bluetooth® module is off by default. If you need to have Bluetooth® working, the module must be powered on using the Wireless Communications applet (see par. 3.8.4), and perform the Discovery procedure (see par. 3.9.2). Suspending the terminal powers off the Bluetooth® radio and drops the piconet (Bluetooth® connection). When the terminal resumes, it takes approximately 10 seconds for the Bluetooth® radio driver to reinitialize the radio.

Area coverage and Bluetooth® radio performance may vary, due to environmental conditions or interference caused by other devices (microwave ovens, radio transmitters, etc.), etc.

15

Page 34

KYMAN™

2

2.4

WWAN CONNECTIONS

Kyman™ GSM/GPRS/EDGE models enhance your connectivity solutions giving you an opening to an international wireless infrastructure that is the standard in Europe and Asia. GSM (Global System for Mobile communications), is a digital mobile phone system based on TDMA; it utilizes the 800, 900, 1800 and 1900 MHz bands. GPRS supports IP (Internet Protocol) and allows accessing Internet and Intranet services, such as sending and receiving e-mail or Web browsing. In order to use a WWAN Connection you have to install a SIM Card (see instructions on par. 1.5).

NOTE

16

In order to avoid wasting energy, the GSM/GPRS module is off by default. If you need to have GSM/GPRS working, the module must be powered on using the Wireless Communications applet (see par. 3.8.4)

Page 35

CONNECTIONS

NOTE

NOTE

2.5

2

Suspending the terminal powers off the GSM/GPRS radio and drops the connection. When the terminal resumes, if the connection was managed by Microsoft Internet Explorer, it is automatically restored, otherwise, the radio connection must be manually re-initialized. The GSM voice capability of this mobile computer has to be addressed to occasional use, in well covered areas. If the coverage is poor, the voice quality can be highly affected. In case of vehicle cradle installations, a good habit is to install the external microphone to minimize the risk of noises and echoes. If the coverage is poor, in case of continuous communication, some degradation of the barcode reading capabilities can be experienced.

CRADLE CONNECTIONS

The Kyman™ can also communicate via RS232, USB and Ethernet, using various cradle models. For further details, refer to the specific cradle model User’s Manual.

17

Page 36

KYMAN™

2

2.6

CONNECTION CABLES

The following cables are listed with their order number. RS232 Direct Connection: 94A051008 WIN-NET SERIAL CABLE (HRS 3500-16P-CV) HOST/PC side 9-pin (female)

Mobile Computer side 16-pin 5 6

RX

3

TX

2

CTS 7 8

7

RTS

8

DSR

4

9

1

11 10 13

DTR

6

GND

5

USB Direct Connection: 94A051009 WIN-NET USB CABLE (HRS 3500-16P-CV) Mobile Computer side 16-pin

18

HOST/PC side 9-pin (female)

13

GND

14

V+

15

D+

16

D-

4 1 3 2

Page 37

CONNECTIONS

2

RS232 Direct Connection: 94A051014 WIN-NET SERIAL PWR CABLE (HRS 3500-16P-CV) Mobile Computer side 16-pin

RX

TX

5 6

TX

3

RX

HOST/PC side 9-pin (female)

2

CTS 7 RTS

CD

DSR

DSR

DTR

CTS

1

8 9 10

8 GND

1

4 13

5

VALIM

2 3

6

GND GND GND

POWER CONNECTOR

USB Direct Connection: 94A051015 WIN-NET USB PWR CABLE (HRS 3500-16P-CV) SHIELD

HOUSING 14

V+

16

D(-)

15

D(+)

HOUSING 1 2 3

3 GND

4

4

13 1 2

POWER VALIM

Power Supply Polarity: VEXT

GND