Page 134

CODE SELECTION (continued) DESCRIPTION enabled

AMB1 disabled

AMC0 enabled

AMC1

GS1 DataBar Expanded disabled

AMD0

Stacked enabled

AMD1

GS1 DataBar Stacked disabled

AME0 enabled

AME1

GS1 DataBar Omnidirectional d= a number from the HEX/Numeric Table d = a number in the range 001-255

132

Gryphon™ D432/D412Plus

Page 135

CODE SELECTION DESCRIPTION

STRING

2D SYMBOLOGIES PDF417 disabled

AGA0 enabled

AGA1

Macro PDF417

Micro PDF417

DataMatrix

QR Family

Micro QR

Postal Codes

Product Reference Guide unbuffered mode

AVB0 buffered mode

AVB1 disabled

AGB0 enabled

AGB1 disabled

AHA0 enabled

AHA1

Minimum Code Length

AHCe

Maximum Code Length

AHDe

Rectangular Style disabled

AHE0 enabled

AHE1 disabled

AIA0 enabled

AIA1 disabled

AIB0 enabled

AIB1 all disabled

ALA0

Australian Post - enabled

ALA1

Japan Post - enabled

ALA2

PLANET - enabled

ALA3

POSTNET - enabled

ALA4

POSTNET with B and B’ - enabled

ALA5

POSTNET and PLANET - enabled

ALA6

POSTNET with B and B’ and PLANET - enabled

ALA7

KIX Code - enabled

ALA8

Royal Mail Code (RM4SCC) - enabled

ALA9

133

Page 136

CODE SELECTION (continued) DESCRIPTION

STRING

2D SYMBOLOGIES Australian Table

IMB

Maxicode

N Table

ALB0

C Table

ALB1 disabled

ALC0 enabled

ALC1

Mode 0

Mode 1

Mode 2

Mode 3

Mode 4

Mode 5

Mode 6

Aztec

Composite Code e= disabled

AJL0 enabled

AJL1 disabled

AJM0 enabled

AJM1 disabled

AJN0 enabled

AJN1 disabled

AJO0 enabled

AJO1 disabled

AJP0 enabled

AJP1 disabled

AJQ0 enabled

AJQ1 disabled

AJR0 enabled

AJR1 disabled

AKA0 enabled

AKA2 disabled

ANA0 enabled

ANA1

Discard Linear disabled

ANB0

Part enabled

ANB1 a number from the HEX/Numeric Table e = a number in the range 0001-3600

134

Gryphon™ D432/D412Plus

Page 137

READING PARAMETERS

DESCRIPTION Trigger Mode

Trigger Type

STRING trigger level

BAA0 trigger pulse

BAA1 normal trigger

BAB0 software trigger

BAB1

Flash On Duration

BF0f

Flash Off Duration

BF1f

Beeper Tone

Beeper Volume tone 1

GBA1 tone 2

GBA2 tone 3

GBA3 tone 4

GBA4 off

GBB0 low

GBB1 medium

GBB2 high

GBB3

Beeper Duration Reads per Cycle

GBCf one read per cycle

BCA0 multiple reads per cycle

BCA1

Scan Timeout User Defined Beeper Tone

User Defined Beeper Volume

BEAf tone 1

GBD1 tone 2

GBD2 tone 3

GBD3 tone 4

GBD4 off

GBE0 low

GBE1 medium

GBE2 high

GBE3

User Defined Beeper Duration

GBFf

Perform User Defined Beep

$?GGG

** this command carries out its specific function and does not need $+ and $-

Product Reference Guide

135

Page 138

CODE ORDERING AND SELECTION Code per Scan

Central Code Transmission

Order by Code Length f= one code per scan

BCB0 all codes per scan

BCB1 disabled

OAA0 enabled

OAA1 disabled

OAB0 enabled - increasing order

OAB1 enabled - decreasing order

OAB2 a number from the HEX/Numeric Table f = a number in the range 01-99

READING PARAMETERS DESCRIPTION

STRING

AUTOSCAN Autoscan Mode

Autoscan Aiming System

Autoscan Hardware Trigger

Autoscan Illumination System

Safety Time disabled

BBA0 enabled in normal mode

BBA1 enabled in pattern mode

BBA2 disabled

BBB0 enabled

BBB1 disabled

BBC0 enabled

BBC1 disabled

BBD0 enabled

BBD1 disabled

BGA0 enabled

BGA1

Safety Time Duration Stand Autoscan Mode

136

BGBf disabled

BBE0 normal

BBE1

Gryphon™ D432/D412Plus

Page 139

READING PARAMETERS (continued) STRING

DESCRIPTION

Aiming System Delay

Good Read Spot f= pattern

BBE2 disabled

BLA00 enable short

BLA03 enable medium

BLA06 enable long

BLA10 disabled

BIA0 enable short

BIA1 enable medium

BIA2 enable long

BIA3 enable continuous

BIA4 a number from the HEX/Numeric Table f = a number in the range 01-99

ADVANCED IMAGE CAPTURE DESCRIPTION

STRING

IMAGE PRESET 1 Basic Configuration Image Format

JPEG format

IAA1

TIFF format

IAA2

JPEG Quality Factor g=

IACg a number from the HEX/Numeric Table g = a number in the range 000-100

Product Reference Guide

137

Page 140

ADVANCED IMAGE CAPTURE DESCRIPTION

STRING

IMAGE PRESET 1 Advanced Configuration Brightness

Contrast

Color Depth i= increase

IAO0IAFi decrease

IAO1IAF1i increase

IAP0IAEi decrease

IAP1IAEi

2 gray levels

IAG0

16 gray levels

IAG1

256 gray levels

IAG2 a number from the HEX/Numeric Table i = a number in the range 0-100

ADVANCED IMAGE CAPTURE DESCRIPTION

STRING

IMAGE PRESET 2 Basic Configuration Image Format

JPEG format

IBA1

TIFF format

IBA2

JPEG Quality Factor

IBCg

Advanced Configuration Brightness

Contrast

Color Depth increase

IBO0IBFi decrease

IBO1IBF1i increase

IBP0IBEi decrease

IBP1IBEi

2 gray levels

IBG0

16 gray levels

IBG1

256 gray levels

IBG2 g, i = a number from the HEX/Numeric Table g = a number in the range 000-100 i = a number in the range 0-100

138

Gryphon™ D432/D412Plus

Page 141

ADVANCED IMAGE CAPTURE DESCRIPTION

STRING

IMAGE PRESET 3 Basic Configuration Image Format

JPEG format

ICA1

TIFF format

ICA2

JPEG Quality Factor

ICCg

Advanced Configuration Brightness

Contrast

Color Depth increase

ICO0ICFi decrease

ICO1ICF1i increase

ICP0ICEi decrease

ICP1ICEi

2 gray levels

ICG0

16 gray levels

ICG1

256 gray levels

ICG2 g, i = a number from the HEX/Numeric Table g = a number in the range 000-100 i = a number in the range 0-100 ADVANCED IMAGE CAPTURE DESCRIPTION

STRING

IMAGE PRESET 4 Basic Configuration Image Format

JPEG format

IDA1

TIFF format

IDA2

JPEG Quality Factor

IDCg

Advanced Configuration Brightness

Product Reference Guide increase

IDO0IDFi decrease

IDO1IDF1i

139

Page 142

ADVANCED IMAGE CAPTURE (continued) DESCRIPTION

STRING

Contrast

Color Depth increase

IDP0IDEi decrease

IDP1IDEi

2 gray levels

IDG0

16 gray levels

IDG1

256 gray levels

IDG2 g, i = a number from the HEX/Numeric Table g = a number in the range 000-100 i = a number in the range 0-100

140