The text of a manual · part 17 of 20
Gryphon D432/D412Plus Barcode Reader Product Reference Guide: Appendix A, pages 134 to 142
Pages 134 to 142 of 160, from Gryphon D432/D412Plus Barcode Reader Product Reference Guide
The original document is the PDF (3.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic D432
Page 134
CODE SELECTION (continued) DESCRIPTION enabled
AMB1 disabled
AMC0 enabled
AMC1
GS1 DataBar Expanded disabled
AMD0
Stacked enabled
AMD1
GS1 DataBar Stacked disabled
AME0 enabled
AME1
GS1 DataBar Omnidirectional d= a number from the HEX/Numeric Table d = a number in the range 001-255
132
Gryphon™ D432/D412Plus
Page 135
CODE SELECTION DESCRIPTION
STRING
2D SYMBOLOGIES PDF417 disabled
AGA0 enabled
AGA1
Macro PDF417
Micro PDF417
DataMatrix
QR Family
Micro QR
Postal Codes
Product Reference Guide unbuffered mode
AVB0 buffered mode
AVB1 disabled
AGB0 enabled
AGB1 disabled
AHA0 enabled
AHA1
Minimum Code Length
AHCe
Maximum Code Length
AHDe
Rectangular Style disabled
AHE0 enabled
AHE1 disabled
AIA0 enabled
AIA1 disabled
AIB0 enabled
AIB1 all disabled
ALA0
Australian Post - enabled
ALA1
Japan Post - enabled
ALA2
PLANET - enabled
ALA3
POSTNET - enabled
ALA4
POSTNET with B and B’ - enabled
ALA5
POSTNET and PLANET - enabled
ALA6
POSTNET with B and B’ and PLANET - enabled
ALA7
KIX Code - enabled
ALA8
Royal Mail Code (RM4SCC) - enabled
ALA9
133
Page 136
CODE SELECTION (continued) DESCRIPTION
STRING
2D SYMBOLOGIES Australian Table
IMB
Maxicode
N Table
ALB0
C Table
ALB1 disabled
ALC0 enabled
ALC1
Mode 0
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
Aztec
Composite Code e= disabled
AJL0 enabled
AJL1 disabled
AJM0 enabled
AJM1 disabled
AJN0 enabled
AJN1 disabled
AJO0 enabled
AJO1 disabled
AJP0 enabled
AJP1 disabled
AJQ0 enabled
AJQ1 disabled
AJR0 enabled
AJR1 disabled
AKA0 enabled
AKA2 disabled
ANA0 enabled
ANA1
Discard Linear disabled
ANB0
Part enabled
ANB1 a number from the HEX/Numeric Table e = a number in the range 0001-3600
134
Gryphon™ D432/D412Plus
Page 137
READING PARAMETERS
DESCRIPTION Trigger Mode
Trigger Type
STRING trigger level
BAA0 trigger pulse
BAA1 normal trigger
BAB0 software trigger
BAB1
Flash On Duration
BF0f
Flash Off Duration
BF1f
Beeper Tone
Beeper Volume tone 1
GBA1 tone 2
GBA2 tone 3
GBA3 tone 4
GBA4 off
GBB0 low
GBB1 medium
GBB2 high
GBB3
Beeper Duration Reads per Cycle
GBCf one read per cycle
BCA0 multiple reads per cycle
BCA1
Scan Timeout User Defined Beeper Tone
User Defined Beeper Volume
BEAf tone 1
GBD1 tone 2
GBD2 tone 3
GBD3 tone 4
GBD4 off
GBE0 low
GBE1 medium
GBE2 high
GBE3
User Defined Beeper Duration
GBFf
Perform User Defined Beep
$?GGG
** this command carries out its specific function and does not need $+ and $-
Product Reference Guide
135
Page 138
CODE ORDERING AND SELECTION Code per Scan
Central Code Transmission
Order by Code Length f= one code per scan
BCB0 all codes per scan
BCB1 disabled
OAA0 enabled
OAA1 disabled
OAB0 enabled - increasing order
OAB1 enabled - decreasing order
OAB2 a number from the HEX/Numeric Table f = a number in the range 01-99
READING PARAMETERS DESCRIPTION
STRING
AUTOSCAN Autoscan Mode
Autoscan Aiming System
Autoscan Hardware Trigger
Autoscan Illumination System
Safety Time disabled
BBA0 enabled in normal mode
BBA1 enabled in pattern mode
BBA2 disabled
BBB0 enabled
BBB1 disabled
BBC0 enabled
BBC1 disabled
BBD0 enabled
BBD1 disabled
BGA0 enabled
BGA1
Safety Time Duration Stand Autoscan Mode
136
BGBf disabled
BBE0 normal
BBE1
Gryphon™ D432/D412Plus
Page 139
READING PARAMETERS (continued) STRING
DESCRIPTION
Aiming System Delay
Good Read Spot f= pattern
BBE2 disabled
BLA00 enable short
BLA03 enable medium
BLA06 enable long
BLA10 disabled
BIA0 enable short
BIA1 enable medium
BIA2 enable long
BIA3 enable continuous
BIA4 a number from the HEX/Numeric Table f = a number in the range 01-99
ADVANCED IMAGE CAPTURE DESCRIPTION
STRING
IMAGE PRESET 1 Basic Configuration Image Format
JPEG format
IAA1
TIFF format
IAA2
JPEG Quality Factor g=
IACg a number from the HEX/Numeric Table g = a number in the range 000-100
Product Reference Guide
137
Page 140
ADVANCED IMAGE CAPTURE DESCRIPTION
STRING
IMAGE PRESET 1 Advanced Configuration Brightness
Contrast
Color Depth i= increase
IAO0IAFi decrease
IAO1IAF1i increase
IAP0IAEi decrease
IAP1IAEi
2 gray levels
IAG0
16 gray levels
IAG1
256 gray levels
IAG2 a number from the HEX/Numeric Table i = a number in the range 0-100
ADVANCED IMAGE CAPTURE DESCRIPTION
STRING
IMAGE PRESET 2 Basic Configuration Image Format
JPEG format
IBA1
TIFF format
IBA2
JPEG Quality Factor
IBCg
Advanced Configuration Brightness
Contrast
Color Depth increase
IBO0IBFi decrease
IBO1IBF1i increase
IBP0IBEi decrease
IBP1IBEi
2 gray levels
IBG0
16 gray levels
IBG1
256 gray levels
IBG2 g, i = a number from the HEX/Numeric Table g = a number in the range 000-100 i = a number in the range 0-100
138
Gryphon™ D432/D412Plus
Page 141
ADVANCED IMAGE CAPTURE DESCRIPTION
STRING
IMAGE PRESET 3 Basic Configuration Image Format
JPEG format
ICA1
TIFF format
ICA2
JPEG Quality Factor
ICCg
Advanced Configuration Brightness
Contrast
Color Depth increase
ICO0ICFi decrease
ICO1ICF1i increase
ICP0ICEi decrease
ICP1ICEi
2 gray levels
ICG0
16 gray levels
ICG1
256 gray levels
ICG2 g, i = a number from the HEX/Numeric Table g = a number in the range 000-100 i = a number in the range 0-100 ADVANCED IMAGE CAPTURE DESCRIPTION
STRING
IMAGE PRESET 4 Basic Configuration Image Format
JPEG format
IDA1
TIFF format
IDA2
JPEG Quality Factor
IDCg
Advanced Configuration Brightness
Product Reference Guide increase
IDO0IDFi decrease
IDO1IDF1i
139
Page 142
ADVANCED IMAGE CAPTURE (continued) DESCRIPTION
STRING
Contrast
Color Depth increase
IDP0IDEi decrease
IDP1IDEi
2 gray levels
IDG0
16 gray levels
IDG1
256 gray levels
IDG2 g, i = a number from the HEX/Numeric Table g = a number in the range 000-100 i = a number in the range 0-100
140
Gryphon™ D432/D412Plus