Page 115
Chapter 5 References RS-232, USB COM ACK/NACK Protocol The transmission protocol takes place between reader and Host. Once the reader has read a code, it emits a good read beep and passes its data to the Host. When ACK/NACK is disabled, there is no control from reader to Host transmission. When ACK/NACK is enabled, the Host sends an ACK character (06 HEX) in the case of good reception or the NACK character (15 HEX) requesting re-transmission, in the case of bad reception. If the reader does receive an ACK, no signal will be emitted; whereas, if it does not receive an ACK or NACK, it will emit a wrong reception tone after a few seconds. Gryphon D432/D412Plus reader cannot read barcodes while waiting for the Host response.
RX Timeout This parameter can be used to automatically end data reception from the Host after the specific period of time. If no character is received from Host, after the timeout expires, any incomplete string (any string not terminated by <CR>) is flushed from the device buffer.
USB Keyboard Keyboard Speed This parameter manages the transmission speed of characters to the Host. A fast Keyboard Speed allows rapid transmission of a great amount of characters (for example 2D codes), but it might not be compatible with slower systems.
Product Reference Guide
113
Page 116
References
Code Selection Issue Identical Codes This parameter manages the code transmission when more than one code containing the same information is detected in a single scan. All identical codes are transmitted to the Host when the parameter is enabled; if disabled, only one of the identical codes is sent.
Reading Parameters Safety Time Safety time prevents the device from immediately decoding the same code more than once. A timeout can be set up to 9.9 seconds before the decoder will accept the same code. Reading is immediate if the code changes. The safety time parameter is not applicable when all codes per scan is enabled or when setting one read per cycle in normal (hardware) trigger operating mode.
Configuration Editing Commands The following commands carry out their specific function and do not require reading the Enter or Exit and Save Configuration codes.
114
Command
Description
AMHKGPAOFNGNENEIEPANHOGOCK AHHPMBAMDKEOFMHMLJALECHGIK AKCBPJCJGIIJCMCFGPLCMMMNLK AEFBJLBGMHPKMOGNKKNDPDMGGK AAPHBAJIDGHPOJKEFPNCEACBHK AFKFBKNGLGMOMELLGOPCMJFKIK DDDDLDLLLDDLLLLDDDLDDLDLDL
Restore Gryphon D432/D412Plus reader default configuration.
AMHKGPBOFNGNENEIEPANHOGOCK AHHPMBIMDKEOFMHMLJAKECBEIK AKCBPJCJGIIJCMCEGNOKAKPHJK AEFBJLBGMHPKMKEPKAKIOABEGK AAPHBAJICFGFIBIPPOECDKIJBK AFKFBMIKBFKGOMKNNGLKGNNIKK DLLDLDLLDDLLLLLDDLDDDLDLLL
Transmit the Gryphon D432/D412Plus reader Software release.
AMHOGPBOFNGNENEIEPANHOGOCK AHHPEBAMDKEOFMHMLJAKEACHIK AKCBPJCJGIIJCMCEGNLFCLIPJK AEFBJLBGMHPKMKFLEFBNBOKHGK AAPHBAJIDGHLDGOMCOHJGAAFDK AGKFALIMCNPOKGIEIBDIOGHIKK DLLLLLLLDDDLLLLDLLLDDLDLDL
Transmit the Gryphon D432/D412Plus current configuration in ASCII format to Host.
AMHOHMEMHNGNENEIEPANHOGOCK AHPBIBAMDKEOFMHMLJALFHGFJK AKCBPJCJGIIJCMCEHJIPFPFLNK AEFBJLBGMHPLNOBPKFGHKGAGGK AAPHBAJIDBEDNCGFJDBLCCBHFK AELFAJJEFKLIMPLCLLEIOMIJLK DDDLLLLDLDLLLLLDDDLDDLDLDL
Transmit the Gryphon D432/D412Plus current data format configuration in ASCII format to Host.
Gryphon™ D432/D412Plus
Page 117
Chapter 6 Test Code Symbols Use these 1D and 2D test symbols to check that the reader is imaging and decoding properly, according to your configuration.
UPC-A
52637 48509
1
2
EAN-13
1 234567 000992
Code 39 (Standard)
1
7
1
6
2
Code 128 t
Product Reference Guide e s t
115
Page 118
Test Code Symbols
~~ mies PDF417 . PDF417 DataMatrix (Normal)
eae
DataMatrix (Inverse)
ct
Le
TEE = i aE Fa: