The text of a manual · part 5 of 13
Lynx Instruction Manual, pages 41 to 50
Pages 41 to 50 of 128
The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic D302
Page 41
WEDGE
Some ASCII characters may be missing as this depends on the type of keyboard: these are generally particular characters relative to the various national symbologies. In this case: •
The first 4 characters (Shift, Alt, Ctrl, and Backspace) can only be substituted with keys not used, or substituted with each other.
•
Characters can be substituted with other single symbols (e.g. "SPACE") even if not included in the barcode set used.
•
Characters can be substituted with others corresponding to your keyboard.
The reader signals the end of the procedure with 2 beeps indicating the keys have been registered. 01 : Shift 02 : Alt 03 : Ctrl 04 : Backspace 05 : SPACE 06 : ! 07 : " 08 : # 09 : $ 10 : % 11 : & 12 : ' 13 : ( 14 : ) 15 : * 16 : + 17 : , 18 : 19 : . 20 : / 21 : 0 22 : 1 23 : 2 24 : 3 25 : 4 26 : 5 27 : 6
28 : 7 29 : 8 30 : 9 31 : : 32 : ; 33 : < 34 : = 35 : > 36 : ? 37 : @ 38 : A 39 : B 40 : C 41 : D 42 : E 43 : F 44 : G 45 : H 46 : I 47 : J 48 : K 49 : L 50 : M
51 : N 52 : O 53 : P 54 : Q 55 : R 56 : S 57 : T 58 : U 59 : V 60 : W 61 : X 62 : Y 63 : Z 64 : [ 65 : \ 66 : ] 67 : ^ 68 : _ (underscore) 69 : ` 70 : { 71 : | 72 : } 73 : ~ 74 : DEL
25
Page 42
WEDGE
Extended Keys i'##k i'##k i'##k i'##k
The header/terminator selection is not effected by the reading of the restore default code. In fact, header and terminator default values depend on the interface selection: RS232: no header, terminator CR-LF WEDGE: no header, terminator ENTER These default values are always restored through the reading of RS232 or WEDGE interface selection code. For the WEDGE interface, the following extended keyboard value can also be configured: EXTENDED KEYBOARD TO HEX CONVERSION IBM AT
HEX
83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B
26
KEY ENTER TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 HOME END PG UP PG DOWN ↑ ↓ ← → ESC CTRL (Right) Euro
Page 43
WEDGE
The extended Header/Terminator keys for Wedge Interface users can be customized by defining them through a simple keyboard setting procedure. For example, the Numeric Keypad keys can be set for use as Headers or Terminators by substituting the default extended keys during this procedure. The type of computer or terminal must be selected before activating the keyboard setting command. Press and release a key to set it. Some characters may require more than one key pressed simultaneously during normal use (refer to the manual of your PC or terminal for keyboard use). The exact sequence must be indicated to the reader in this case pressing and releasing the different keys. Example: If one has to press the "Shift" and "4" keys simultaneously on the keyboard to transmit the character "$" to the video, to set the "$", press and release "Shift" then press and release "4". Each pressed and released key must generate an acoustic signal on the reader, otherwise repress the key. Never press more than one key at the same time, even if this corresponds to the normal use of your keyboard. Press "Backspace" to correct a wrong key entry. In this case the reader emits 2 beeps. Note: "CAPS LOCK" and "NUM LOCK" must be off before starting the keyboard setting procedure. "SHIFT" must be repressed for each character and cannot be substituted by "CAPS LOCK". Read the "Extended Keys" code.
27
Page 44
WEDGE
•
If the first 4 KEYS (Shift, Alt, Ctrl, and Backspace) are not available on your keyboard, you can only substitute them with keys not used, or substitute them with each other.
•
Keys 5 to 28 must be defined.
The reader signals the end of the procedure with 2 beeps indicating the keys have been registered. CUSTOM EXTENDED KEYBOARD SETTING TABLE
Custom Order 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
28
HEX 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A
KEY Shift Alt Ctrl Backspace
Page 45
WEDGE
Acoustic Signals Four types of acoustic signals are associated to the following procedures: 1. Enter keyboard setup 2. Exit keyboard setup 3. SHIFT, ALT, CTRL, BACKSPACE keys 4. Keyboard keys (SHIFT, ALT, CTRL, BACKSPACE excluded) These signals facilitate the selection of those characters requiring more than one key pressed simultaneously. Example The transmission of the "%" character implies two different procedures: 1. Press the SHIFT key 2. Press the "5" key The different tones produced by the reader indicate that both the procedures has been successful and that the character has been transmitted.
29
Page 46
OPERATING MODE
2.6
OPERATING MODE
The following two commands carry out their specific function and then exit the configuration environment.
Normal Mode i i i i
""Ak ""Ak ""Ak ""Ak
The reader captures and decodes the image. Then, it sends the data to the PC.
Image Mode i i i i
30
"#Fk "#Fk "#Fk "#Fk
After reading this code the user must pull the trigger to cause the reader to capture the image and transfer it to the PC, via XMODEM_1K protocol if the RS232 interface has been selected. Then, the reader returns to Normal Mode.
Page 47
DATA FORMAT
2.7
DATA FORMAT
With the exception of the Symbology Independent Header and Terminator selections, the parameters of this group can be restored to their default values using the following default code settings: 1) the general “Restore Default” code, see par. 2.2.2, restores all the configuration parameter groups to their default values; 2) the “Data Format Default” code restores the Data Format Symbology Independent and Symbology Dependent parameters to their default values and disables the defined concatenation by resetting all its parameters. The default values of the Symbology Independent Header and Terminator selections are set when reading the interface selection.
DATA FORMAT DEFAULT Data Format Default i&; dk i&; dk i&; dk i&; dk
2.7.1
Symbology Independent Parameters CODE IDENTIFIER Disabled
Custom Code ID i&"" >k i&"" >k i&"" >k i&"" >k i&""Bk i&""Bk i&""Bk i&""Bk
AIM Standard Code ID
CODE LENGTH Disabled
Enabled i&$" Bk i&$" Bk i&$" Bk i&$" Bk i&$"Fk i&$"Fk i&$"Fk i&$"Fk
31
Page 48
DATA FORMAT
SET HEADERS Set Headers 1.
i&%"k i&%"k i&%"k i&%"k
2.
3.
Set the number of characters in the range 00-10. Read the corresponding characters as Hex values from the Hex/Numeric table. Valid values are in the range: 00-7F for RS232 00-9B for Wedge Read the following code to enable the configuration you have set.
HEADERS Disabled
Enabled i&%# Gk i&%# Gk i&%# Gk i&%# Gk i&%#Kk i&%#Kk i&%#Kk i&%#Kk
SET TERMINATORS Set Terminators 1.
i&&"-k i&&"-k i&&"-k i&&"-k
2.
3.
Set the number of characters in the range 00-10. Read the corresponding characters as Hex values from the Hex/Numeric table. Valid values are in the range: 00-7F for RS232 00-9B for Wedge Read the following code to enable the configuration you have set.
TERMINATORS
32
Disabled
Enabled i&&# Ik i&&# Ik i&&# Ik i&&# Ik i&&#Mk i&&#Mk i&&#Mk i&&#Mk
Page 49
DATA FORMAT
2.7.2
Symbology Dependent Parameters
The “Symbology Specific Format Default” code allows restoring the symbology dependent parameters related to a specific code family to the default values.
CUSTOM CODE IDENTIFIER Custom Code Identifier 1.
i&#"gk i&#"gk i&#"gk i&#"gk
2. 3.
Select a Datalogic Standard Code Identifier from the Code Identifier Table in Appendix B. Set the number of characters in the range 0-3, where 0 = Code ID disabled. Read the corresponding characters as Hex values from the Hex/Numeric table. Valid values are in the range 00-7F
SYMBOLOGY SPECIFIC FORMAT Symbology Specific Format i&' i&' i&' i&' k k k k
1. 2.
3.
Select a Datalogic Standard Code Identifier from the Code Identifier Table in Appendix B. Formatting: 0 = select all - Stop 1 = select right - followed by Step 3 2 = select left - followed by Step 3 3 = select middle - followed by a number in the range 000-999 for the starting character and then, by Step 3 4 = discard right - followed by Step 3 5 = discard left - followed by Step 3 6 = discard middle - followed by a number in the range 000-999 for the starting character and then, by Step 3 Set the number of characters to select/discard in the range 000-999.
33
Page 50
DATA FORMAT
SYMBOLOGY HEADERS Symbology Headers i&(" i&(" i&(" i&("
1.
k k k k
2. 3.
4.
Select a Datalogic Standard Code Identifier from the Code Identifier Table in Appendix B. Set the number of characters in the range 0-5. Read the corresponding characters as Hex values from the Hex/Numeric table. Valid values are in the range: 00-7F for RS232 00-9B for Wedge Read the following code to enable the configuration you have set.
HEADERS Headers i&(# i&(# i&(# i&(#
1.
k k k k
2.
Select a Datalogic Standard Code Identifier from the Code Identifier Table in Appendix B. 0 = disabled 1 = enabled
SYMBOLOGY TERMINATORS Symbology Terminators i&)" i&)" i&)" i&)" k k k k
1. 2. 3.
4.
34
Select a Datalogic Standard Code Identifier from the Code Identifier Table in Appendix B. Set the number of characters in the range 0-5. Read the corresponding characters as Hex values from the Hex/Numeric table. Valid values are in the range: 00-7F for RS232 00-9B for Wedge Read the following code to enable the configuration you have set.