Page 21
GETTING STARTED
1.7 1.7.1
1
OPERATING THE READER Aiming System
The LYNX™ reader uses an intelligent aiming system similar to those on cameras. The aiming system creates a field of view where the code is to be positioned:
Figure 4 - Aiming System
When you pull the trigger completely a red beam illuminates the code. If the aiming system is centered and the entire symbology is within the aiming system, you will get a good read. The field of view changes size as you move the reader closer or farther away from the code.
Linear barcode
2D Matrix symbol
Figure 5 - Relative Size and Location of Aiming System Pattern
5
Page 22
LYNX™
1
The field of view created by the aiming system will be smaller when the Lynx™ is closer to the code and larger when it is farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit. (See par. 1.8.1 for further details).
1.7.2
Operating Mode
Two operating modes allow Lynx™ to have a normal functioning by capturing and decoding codes or to function as a camera by capturing images of labels, signatures, and other items. When the reader is in normal operating mode, (see par. 2.6): • point the reader at the target and pull the trigger partially to enable the aiming system. Then, pull it completely to capture and decode the image. The reader will repeatedly flash until the symbol is decoded or timeout is reached. In between the flashes of the reader, the aiming system keeps on showing the field of view on the target (see Figure 5).
• as you are reading code symbols, adjust the distance at which you are holding the reader.
NOTE
The LYNX™ hand-held reader aiming system is designed for general reading and decoding of 1D and 2D symbols. Some variation in reading distance will occur due to narrow bar width and other factors.
When the reader is in image operating mode, (see par. 2.6): •
6 you can use the aiming system to position the reader from the object (ensure the reader is about centered over the target). Adjust the distance at which you are holding the reader (see Figure 5).
Page 23
GETTING STARTED
1.7.3
1
Autoscanning
Normal Mode Lynx™ provides an autoscan command (see par. 2.11), which when enabled, causes the reader to scan continuously and to monitor the central zone of its reading area. In this way, Lynx™ is ready to capture any image (containing a potential code) positioned on a uniform background. The aiming system can be enabled to indicate the reading area of the potential code to be captured. The illumination system can also be enabled when the ambient light conditions are not sufficient to autodetect the potential code to be captured; furthermore, the illumination system increases in intensity for an instant when capturing and decoding an image. A safety time may be defined to prevent Lynx™ from reading the same code repeatedly. If the decoding is completed successfully, the reader starts monitoring the reading area again. In case of decoding failure, Lynx™ keeps on decoding until a potential code is present in the central zone of the reading area. Pattern Mode The Autoscan pattern mode is particularly advised when reading barcodes positioned on a non-uniform background. In these cases Lynx™ may perceive some elements of the background as barcodes and start the decoding. To avoid this undesired effect, the Autoscan Pattern Code is placed in the Lynx™ reading area which prevents decoding. Using this code as the background, code reading takes place normally by presenting desired codes to be read over the Pattern Code. Between each code read, the Pattern Code must be represented to Lynx™. Pattern Code can be printed from the file of the manual (Apx. C) available on the CD-ROM. In case of low ambient light conditions, Lynx™ automatically activates the illumination system. If desired, the illumination system can be enabled so that it is always active.
1.7.4
Camera Control
Exposure and Calibration Two different control modes are available for managing the camera: automatic mode and fixed mode.
7
Page 24
LYNX™
1
The automatic mode provides three different options to get the best tuning of the image to be captured: Automatic based on entire image: camera control mode based on the analysis of the whole image. This mode works well in most of standard applications. It is the default setting. Automatic based on central image: camera control mode based on the analysis of a restricted area positioned in the central zone of the image. This mode is suggested when reading small codes positioned in a dark and extensive background. Automatic for highly reflective surfaces: camera control mode allowing to read codes on highly reflective surfaces. This mode is suggested, for example, when reading codes positioned on plastic or metal surfaces. The fixed mode is particularly suggested for expert users. It requires a camera calibration to adjust the acquisition parameters to the ambient light conditions. The defined values will always be used when working with a fixed exposure. These values are permanently saved in the reader memory. Refer to par. 2.8 for configuration barcodes. Aiming System Calibration The factory-defined Lynx™ aiming system is already correctly and precisely calibrated to the Lynx™ focus distance and therefore works for the most typical applications. However, it is possible to modify the aiming system precision for the following condition: when a fixed reading distance different from the Lynx™ focus distance is used. The Lynx™ focus distance is 115 mm for Lynx™ D302 / Lynx™ D402 and 55 mm for Lynx™ D302 E. Refer to the VisualSetup software program for performing the aiming system calibration.
1.8
DEFINING THE FORMAT
The string of a decoded code to be sent to the host may be formatted as follows: • defining a simple data formatting (see par. 2.7 );
• defining an advanced data formatting giving a complete flexibility in changing the format of data (see par. 2.13).
The codes to be sent to the host may be also selected or ordered depending on the following two conditions: •
8 one code per scan: Lynx™ sends the code being closest to the image center. If the "Central Code Transmission" command is enabled, only the code containing the image center will be transmitted (see par. 2.11.2);
Page 25
GETTING STARTED
•
1 all codes per scan: the codes to be sent to the host may be ordered either by length or by symbology starting from the code being closest to the image center (see par. 2.11.2). When enabling both these criteria, codes belonging to the same symbology are sent to the host depending on their length.
1.8.1
Concatenation
It is possible to concatenate up to 4 different codes, set their length and an intercode delay among them (see par. 2.4 and par. 2.5). When enabling the delay (see par. 2.7.3) one or more global headers and terminators are added to the decoded data. The concatenation procedure may occur in different ways depending on the number of codes to be decoded per image: One code per scan •
If the code resulting from the single decoding of an image belongs to one of the code families to be concatenated, it is saved to the Lynx™ memory waiting for other codes to complete the concatenation.
•
If the code belongs to the same family of a code previously saved, it overwrites to old one.
•
If the code resulting from the decoding does not belong to one of the code families to be concatenated, it causes the concatenation failure and clears the temporary memory. If the "Concatenation Failure Transmission" command is set to "Tx codes causing failure" (see par. 2.7.3), this code will be sent in the output message.
All codes per scan •
All codes resulting from the decoding of an image and belonging to one of the families to be concatenated are saved to the Lynx™ memory waiting for other codes to complete the concatenation.
•
If one or more codes resulting from the decoding belong to the same family of codes previously saved, they overwrite the old ones.
•
When the image contains no code to be concatenated, the concatenation fails and the reader temporary memory is cleared. If the "Concatenation Failure Transmission" command is set to "Tx codes causing failure" (see par. 2.7.3), the codes causing the concatenation failure will be sent in the output message.
9
Page 26
LYNX™
1
1.9
INDICATORS
1.9.1
LED Indicators
The following LED indicators signal the reader functions. LED
Behavior
Red (Figure A,1)
Green (Figure A,2)
1.9.2
Reader Power On Normal Functioning lights until a beep occurs. lights when a wrong read Then, it turns off. occurs. Lights for the entire time the aiming system is enabled. It turns off only when the trigger is released and the aiming system is disabled. lights when a symbol has been read and decoded.
Beeper
The Lynx™ basic software provides beeper signals for good/wrong reading or successful/unsuccessful software upgrade. Its tone, volume and duration can be directly configured by using the codes given in par. 2.11. The application program can also manage the beeper (User Defined Beeper) when the reader is controlled by a Host PC. It is possible to activate the beeper by sending a command from the Host to the reader via the current communication interface. The codes given in par. 2.11.1 allow defining the beeper properties.
The configuration of the User Defined Beeper does not influence or change the functioning of the beeper managed by the Lynx™ basic software (see par. 1.9.2) NOTE
10
Page 27
CONFIGURATION USING BARCODE SYMBOLS
2
2
CONFIGURATION USING BARCODE SYMBOLS
This section describes the programming method of using configuration barcode symbols to program your reader. By using the LYNX™ reader to read/decode these special configuration symbols, you can configure, and obtain information from its system software. When you are reading configuration barcode symbols, carefully aim the LYNX™ 2D reader to avoid reading adjacent symbols. The configuration barcode symbols in this chapter are divided into logical sections according to the type of configuration required, (RS232 configuration, Code selection, etc.). If arguments are required with a command, you can read additional barcode labels (typically digits) from Appendix C. To configure your reader: 1.
Open the folded page in Appendix C the Hex/Numeric table and keep it open during the device configuration.
2.
Read the Enter Configuration code ONCE, available on the folded page in Appendix C or in par. 2.2.1.
3.
Modify the desired parameters in one or more sections by reading the parameter code and selecting the value from the Hex/Numeric table or by following the given procedures. = parameter available only for Lynx™ D402
4.
Read the Exit and Save Configuration code ONCE, available on the folded page in Appendix C or in par. 2.2.1.
Example: To set the maximum length of characters in a Code 39 barcode symbol that the reader will decode to 32: • first read the Maximum Length symbol for Code 39 on page 45.
• then read the symbol for the digit "3" and lastly the symbol for the digit "2" in Appendix C.
11
Page 28
LYNX™
2
2.1
DEFAULT SETTINGS
Configuration Field RS232 Communication Baud Rate Parity, Data Bits, Stop Bits Handshake Protocol FIFO Intercharacter Delay RX Timeout Intercode Delay WEDGE-Communication *Keyboard nationality CapsLock NumLock Intercharacter Delay Intercode Delay Operating Mode Operating Mode Data Format-Symbology Independent Parameters Code Identifier Code Length *Header *Terminator
Default Setting 115200 No parity; 8 Data bits; 1 Stop bit None None Enabled 0 10 seconds 0 USA OFF OFF 0 0 Normal Mode Disabled Disabled No headers CR and LF terminators for RS232 ENTER terminator for Wedge
Data Format-Symbology Dependent Parameters Custom Code Identifier Disabled Symbology Specific Format Select All Header Symbology No headers Terminator Symbology No terminators Symbology Character Substitution No character to substitute Symbology Character Deletion No character to delete Data Format-Concatenation Concatenation Disabled Define Concatenation 2EAN/UPC codes concatenated Set First Concatenated Code Length 000 = any length Set Second Concatenated Code Length 000 = any length Set Third Concatenated Code Length 000 = any length Set Fourth Concatenated Code Length 000 = any length Concatenation with Intercode Delay Disabled Concatenation Timeout 10 seconds * The default values of these parameters are set when reading the interface selection.
12
Page 29
CONFIGURATION USING BARCODE SYMBOLS
Configuration Field Data Format-Concatenation Concatenation Failure Transmission Transmission after Timeout Concatenation Result Code ID Advanced Formatting Format enable/disable Camera Control Exposure Mode Power Save Illumination Power EAN/UPC Selection Add-On UPCE Expansion Code 39 Selection Code39 Full ASCII Code Length Check Minimum Length Maximum Length Start/Stop Character MSI Selection Code Length Check Minimum Length Maximum Length Interleaved 2 of 5 Selection Code Length Check Minimum Length Maximum Length Codabar Selection Code Length Check Minimum Length Maximum Length Code 128 Code128 Selection Code Length Check Minimum Length Maximum Length
2
Default Setting Tx codes causing failure No code transmission No code identifier Disabled Automatic, based on entire image Max power Enabled Disabled Disabled Enabled - no check digit Disabled Disabled 001 255 Disabled Disabled Disabled 001 255 Enabled - no check digit Disabled 014 255 Disabled Disabled 001 255 Enabled Disabled 001 255
13
Page 30
LYNX™
2 Configuration Field EAN128 Selection Code Length Check Minimum Length Maximum Length Code 93 Selection Code Length Check Minimum Length Maximum Length Codablock A Selection Code Length Check Minimum Length Maximum Length Codablock F Selection Code Length Check Minimum Length Maximum Length Codablock F EAN Selection Code Length Check Minimum Length Maximum Length RSS Code RSS Expanded code RSS Limited RSS14 and RSS14 Truncated Composite Codes Composite Codes PDF-417 Selection Macro PDF417 Micro PDF-417 Selection Data Matrix Selection Rectangular Style Minimum Code Length Maximum Code Length
14
Default Setting Disabled Disabled 001 255 Disabled Disabled 001 255 Disabled Disabled 001 255 Disabled Disabled 001 255 Disabled Disabled 001 255 Disabled Disabled Disabled Disabled Enabled Buffered Disabled Enabled - normal & reverse Enabled 0001 3600