Page 21
CATCHER™ D531 SERIES
DEFAULT VALUES USB DEFAULT SETTINGS DATA FORMAT: code identifier disabled, no field adjustment, code length not transmitted, character replacement disabled. USB KEYBOARD: USA keyboard, inter-character and inter-code delays disabled, control character emulation = ctrl+shift+key. USB COM: no handshaking, delay disabled, rx timeout 5 sec., ack/nack disabled, serial decode control = disabled, serial sleep control = disabled. Default Headers and Terminators for each USB mode: - USB-KBD: no header, terminator = ENTER - USB-KBD APPLE: no header, terminator = ENTER - USB-KBD-ALT-MODE: no header, terminator = CR - USB-COM: no header, terminator = CR-LF - USB-IBM-TABLE TOP: not applicable - USB-IBM-HAND HELD: not applicable RS232 Standard DEFAULT SETTINGS 9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx timeout 5 sec., ack/nack disabled, serial decode control = disabled, serial sleep control = disabled. DATA FORMAT: code identifier disabled, no field adjustment, code length not transmitted, no header, terminator = CR-LF, character replacement disabled. RS232 Nixdorf DEFAULT SETTINGS 9600 baud, parity odd, 8 data bits, 1 stop bit, handshaking hardware (RTS/CTS), delay disabled, rx timeout 9.9 sec., ack/nack disabled, serial decode control = disabled, serial sleep control = disabled. DATA FORMAT: code identifier enabled, no field adjustment, code length not transmitted, no header, terminator = CR, character replacement disabled. RS232 Fujitsu DEFAULT SETTINGS 9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx timeout 2 sec., ack/nack disabled, serial decode control = disabled, serial sleep control = disabled. DATA FORMAT: code identifier enabled, no field adjustment, code length not transmitted, no header, terminator = CR, character replacement disabled. RS232 ICL DEFAULT SETTINGS 9600 baud, parity even, 8 data bits, 1 stop bit, handshaking RTS always on, delay disabled, rx timeout 9.9 sec., ack/nack disabled, serial decode control = disabled, serial sleep control = disabled. DATA FORMAT: code identifier enabled, no field adjustment, code length not transmitted, no header, terminator = CR, character replacement disabled. WEDGE DEFAULT SETTINGS USA keyboard, caps lock off, caps lock auto-recognition enabled, num lock unchanged, inter-character and inter-code delays disabled, control character emulation = ctrl+shift+key. DATA FORMAT: code identifier disabled, no field adjustment, code length not transmitted, no header, terminator = ENTER, character replacement disabled.
15
Page 22
DATALOGIC POWER SAVE stand by state enabled, enter stand by timeout 5 min., sleep state enabled, sleep state timeout 60 min. READING PARAMETERS Timeout between same code consecutive readings 0.3 sec, beeper intensity high, tone 2, beeper type monotone, beeper length short, single line decoding duration = 5 sec., timeout OFF before raster = 2 sec. DECODING PARAMETERS ink spread disabled, overflow control enabled, interdigit control enabled, decoding safety = one read, code 39 stitching enabled, code 128 stitching enabled. CODE SELECTION Enabled codes •
•
• •
EAN 8/EAN 13 / UPC A/UPC E without ADD ON check digit transmitted, no conversions, autodiscriminate decoding safety = 15 reads Interleaved 2/5 check digit control and transmission, variable length code, 6-99 characters Standard Code 39 no check digit control, variable length code, 4-99 characters Code 128 variable length code, 1-99 characters
Disabled codes EAN 128, ISBT128, Code 93, Codabar, MSI, Plessey, RSS ADVANCED FORMATTING PARAMETERS concatenation disabled, no advanced formats defined.
16
Page 23
CATCHER™ D531 SERIES
OPERATING TEST Read the test codes below.
EAN-8
1234 5670
EAN-13
1 234567 000992
Code 39 (Normal)
1
7
1
6
2
Code 128 t e s t
Interleaved 2 of 5
0123456784 YOUR READER IS NOW READY TO READ BARCODES. To change the defaults see the "Presentation Scanners Software Configuration Manual".
17
Page 24
DATALOGIC
TECHNICAL FEATURES Electrical Features Power Supply
+5 Vdc ± 5%
Consumption
340 mA @ 5v
Interfaces
RS232, USB, Keyboard Wedge
Reading Indicators
Red&Green Bicolored LED, Beeper
Optical Features
Reading Field
Visible laser diode (in the range 630 to 680 nm) See reading diagram
Max Resolution
0.12 mm (5 mils)
PCS
Min. 27% (Datalogic Test Chart)
Light Source
Scan Pattern
5 directions, 20 lines
Scan Rate
1500 scans/seconds
Environmental Features Operating Temperature
0° to + 40 °C (32° to 104 °F)
Storage Temperature
-20° to +70 °C (-4° to 158 °F)
Humidity
0% to 90% RH (non-condensing)
Drop Resistance
IEC 68-2-32 Test ED 1.2 m
ESD Protection
16 KV
Protection Class
IP40
Mechanical Features Weight (without cable)
340 g (12 oz)
Dimensions
87 x 85 x 150 mm / 3.4 x 3.3 x 5.9 in
18
Page 25
CATCHER™ D531 SERIES
READING DIAGRAM Reading Zones (15° skew angle)
15
10
CODE 39 0.21 mm (8 mils)
EAN13 M=1 0.33 mm (13 mils)
5
0
-5
-10
CODE 39 0.13 mm (5 mils)
-15 0
5
10
15
20
25
(cm)
19
Page 26
DATALOGIC
SCANNER DATA ENTRY H = high tone Beeper one beep
LED 2
Green constant
L = low tone Meaning Correct read of a code in normal mode. It remains constant once the decoding process has been successfully completed and the scanner is in Timeout between same code readings.
1
LH
Red constant
It is constant in normal mode while the Laser is ON and the scanner is ready to read a new code (not in Timeout between same code readings).
Red constant
No read in single line mode after Single Line Decoding Duration timeout.
Red blinking fast
It blinks fast when the scanner is in Stand-by mode.
Red blinking slow
It blinks slower when the scanner is in Sleep mode.
Green/Red blinking alternatively
They turn on alternatively during serial configuration.
1 only the Beeper Intensity command can modify these signals.
2 the data entry good read tone is user-configurable with all the Beeper commands in the Reading Parameter section.
WARRANTY Datalogic warranties this product against defects in workmanship and materials, for a period of 24 months from the date of shipment, provided that the product is operated under normal and proper conditions. Datalogic has the faculty to repair or replace the product, these provisions do not prolong the original warranty term. The warranty does not apply to any product that has been subject to misuse, accidental damage, unauthorized repair or tampering.
20
Page 27
CATCHER™ D531 SERIES
SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.com and click on the links indicated for further information including: •
PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities including: - DL Sm@rtSet™ a Windows-based utility program which allows device configuration using a PC. It provides RS232 interface configuration as well as configuration barcode printing.
•
SERVICES & SUPPORT - Datalogic Services Agreements
-
Warranty
Extensions and
Maintenance
- Authorised Repair Centres •
CONTACT US E-mail form and listing of Datalogic Subsidiaries
PATENTS This product is covered by one or more of the following patents: U.S. patents 5,689,102; 5,992,740; 6,196,462; 6,202,928; 6,260,764; 6,305,606 and 6,834,806 European patents 858636; 895175; 926620 and 1112546 Dutch patents 1001510; 1008260; 1009156; 1009332; 1010088 and 1012189 Additional patents pending.
COMPLIANCE
21
Page 28
DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy
05 dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el
CATCHER DXXX e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: den nachstehenden angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:
89/336/EEC EMC Directive e and et und y
92/31/EEC, 93/68/EEC emendamenti successivi further amendments ses successifs amendements späteren Abänderungen succesivas enmiendas
Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti. On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety. Basées sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits. Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen. Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto. Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:
EN 55022, August 1994:
LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT (ITE)
EN 55024, September 1998:
INFORMATION TECHNOLOGY EQUIPMENT, IMMUNITY CHARACTERISTICS. LIMITS AND METHODS OF MEASUREMENTS
Lippo di Calderara, 05/04/2005 Ruggero Cacioppo Quality Assurance Laboratory Manager