Page 51

Electrical wiring sequence: 1. 2. 3. 4. 5.

SCANNER - Mounting base (two connections, 15-pin ‘D’ and RJ-45) ETHERNET - Host (Network) COM 1 / COM 2 - Serial communications TRIG – Trigger POWER - Power supply or user-supplied

Cable Jacket Stripping

Strip All Wires

COM 1 = 3 1/2”, COM 2 = 3” 3 1/2” 2 3/4”

1/4” 1/4” 1/4”

Wiring Installation Sequence (Connection Panel)

Wiring Installation Sequence (Circuit Board) and TB Wiring Tables

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 52

Enhanced Interface Module

Enhanced Interface Module Wiring tables, printed on the interface module, help simplify installation.

Enhanced Interface Module Terminal Block Locations

See also: Drawing 113490 in Appendix F.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 53

Electrical wiring sequence: 1. 2. 3. 4. 5. 6. 7. 8.

SCANNER - Mounting base (two connections, 15-pin ‘D’ and RJ-45) ETHERNET - Host (Network) COM 1 / COM 2 - Serial communications FIELDBUS (DeviceNet or Profibus, optional) TRIG – Trigger TACH – Tachometer POWER - Power supply or user-supplied I/O 1 through I/O 4 - I/O module(s) (optional)

Cable Jacket Stripping

Strip All Wires

COM 1 = 3 1/2”, COM 2 = 3” 4 3/8” 3 1/2” 3 1/4” 2 3/4” 2 1/2”

1/4” 1/4” 1/4” 1/4” 1/4” 1/4”

Wiring Installation Sequence (Connection Panel)

Wiring Installation Sequence (Circuit Board) and TB Wiring Tables

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 54

Power Requirements IMPORTANT: When planning your installation wiring, remember all power connections must be quick-disconnect. For PERMANENTLY CONNECTED EQUIPMENT (i.e., AL5010 using DC power) a readily accessible disconnect device must be incorporated in the building installation wiring. For PLUGGABLE EQUIPMENT (i.e., AL5010 using AC power supply with non-detachable power cord), the socket-outlet must be installed near the equipment and must be easily accessible.

Power Supply Connections CAUTION: Follow all safety procedures regarding high-voltage as outlined in Chapter 2, Safety. No power should be applied to any device until all wiring is completed and checked for accuracy. REMEMBER: The socket-outlet must be installed near the AL5010’s power supply. The outlet must be a readily accessible disconnect device.

Using Accu-Sort Power Supplies Single Reader The AL5010 reader requires 25 watts (maximum) of power. The Accu-Sort power supplies are IP54 rated for industrial environments. The supply includes a power cord for either 125V or 230V applications. 1. Locate the POWER terminal blocks on the interface module. 2. Connect the power supply wiring to the terminal blocks as shown below. 3. Make sure wiring cannot come loose from the terminal blocks. 4. Properly tighten the cord grips.

Multiple Readers When a multiple reader application uses Accu-Sort power supplies, each AL5010 is powered by a separate power supply. DO NOT connect power supplies in parallel. (See drawing in Appendix F.) Power Connections Using Other Power Supplies IMPORTANT: All non Accu-Sort power supplies, whether for single or multiple reader applications, must be an LPS or Class 2 power supply. The supply must provide 25 watts (10-28 VDC) of power to each AL5010.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 55

Trigger Connections The AL5010 supports three trigger modes: hardware, software, and continuous. When using hardware trigger, one or more input signals “trigger” the reader. Software trigger is accomplished by sending a specific ASCII message via serial or network communications. Continuous trigger requires no external trigger. When a hardware trigger (i.e., package detector) is required, Accu-Sort’s retro-reflective photoeye (PN 100020569) is recommended.

Wiring Trigger to the Enhanced Interface Module Connect trigger wiring to the interface module terminal blocks. Wire the Accu-Sort photoeye as shown below.

Enhanced Interface Module

Basic Interface Module

In applications using a photoeye other than the Accu-Sort standard, follow the TRIGGER wiring table to assure proper wiring. The trigger must be able to operate using the +24V DC source (24V) and not draw more than 100mA. The trigger input must be able to sink (or source) 10mA at +24V DC. NOTE: To confirm the Trigger photoeye is functioning properly, watch the Trigger LED while the photoeye’s beam is blocked. (See Chapter 5 for details.) The Accu-Sort photoeye also includes a status LED. Multiple Readers In controller/client applications, wire the trigger photoeye to the AL5010 set up as the controller. (See drawing in Appendix F.)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 56

Tachometer Connections In applications where product tracking is required, a tachometer is typically used. When a tachometer is required, the Accu-Sort tachometer is recommended. Connect the tachometer wiring to the interface module terminal blocks.

Wiring Tachometer to the Enhanced Interface Module

WARNING: The maximum tachometer current should not be more than 0.3 amps @ 24 volts. If your application uses a tachometer other than the one available from AccuSort, follow the TACH wiring table to assure proper wiring. Multiple Readers In controller/client applications, wire the tachometer to the AL5010 set up as the controller. (See drawing in Appendix F.)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 57

Serial Communications Connections (COM1 and COM2) The interface module provides an RS232/RS422 terminal block for serial point-to-point communications. Typically, network communications will use Ethernet.

Enhanced Interface Module Basic Interface Module Serial Communications Wiring (RS232/422) RS232 Connections Use RS232 for a direct connection to a controller, personal computer, or other device. RS232 provides point-to-point communications at distances up to 50 feet (15.2 meters). If longer cable lengths are needed, use RS422. RS232 connections are made to the COM1 and COM2 terminal blocks. Follow the SERIAL COM / RS232 wiring table to assure proper wiring.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 58

IMPORTANT: Before attempting to use RS232 communications with RTS/CTS, contact Accu-Sort Customer Service for additional information.

RS422 Connections Use RS422 for a direct connection to a controller, personal computer, or other device. RS422 provides point-to-point communications at distances up to 1000 feet (300 meters). RS422 connections are made to the COM1 and COM2 terminal block. Follow the SERIAL COM / RS422 wiring table to assure proper wiring. Line Termination The end devices on an RS422 point-to-point connection must be terminated. A termination resistor is pre-installed in the interface module. The HOST end of the connection must also be terminated using a 120-ohm resistor between the RECEIVE+ and RECEIVE- terminals.

Ethernet Communications Connections Use Ethernet for network/host communications or multiple-reader networks. Ethernet communications cabling can be run up to 330 feet (100 meters). Ethernet connections are made to the Network connector on the Interface Module’s connector panel.

Ethernet Connections to Basic Interface Module

NOTE: To simplify network installations, Accu-Sort offers these options:

CAT 6 network cables (7 and 15 ft. lengths) a 5-port Ethernet switch (dual speed 10/100) and an 8-port dual speed Ethernet switch (10/100).

Multiple Readers Most multi-reader applications will use Ethernet or EtherNet/IP communications. See drawing 113492 in Appendix F for wiring details.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 59

I/O Module Connections The Enhanced Interface Module supports up to four (4) optional input or output (I/O) modules. The modules listed in the table below may be used. These modules function like switches; they do not supply a voltage. (See Appendix A.) Connect I/O wiring to the correct terminal blocks. When using DC modules, observe the polarity of the connections illustrated on the circuit board.

I/O Module Wiring Available I/O Modules for use with AL5010 Part Number

Description

Color

Rating

Current Range

1000056135

DC Input Module white

3.3 to 32 VDC

32 mA

1000056136

DC Output Module red

3 to 60 VDC

3 A max. *

1000056137

AC Output Module black

12 to 42 VACPeak

3 A max. *

NOTE: Relay modules are only for connection to SELV, LPS power source and shall also meet the requirements for Class 2. * Derate 33mA/deg above 25C.

See also: Drawing 113490 in Appendix F.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 60

Output Module Application Shown below is a typical output module application. When connecting high impedance loads, you may need to add a resistor in parallel with the load. This resistor (typically 300 to 6,000 ohms) provides a continuous minimum current flow (10 mA DC or 50 mA AC) through the output module in the closed state. Output Module TB +

Fuse Recommended

Load

Optional Resistor

+ AC or DC Source

Optional Resistor for High Impedance Loads Back Electromotive Force (EMF) is sometimes generated when an inductive load is switched off. Back EMF may damage the output module. A diode in parallel with the inductive device dissipates the back EMF. Output Module TB +

Fuse Recommended

Inductive Load

Optional Diode

+ DC Source

Optional Diode to Dissipate Back EMF An example output module application is the use of a Stack Light. The AL5010 would use three output modules to send signals to the stack light to visually indicate specific conditions (e.g., green = read, yellow = multiple codes, red = no read). (See drawing in Appendix F.) Input Module Application Input module 1000056135 is most often used for an End Trigger Photoeye application. (See drawing 113490 sheet 3 in Appendix F.) NOTE: Any other input module application requires custom software. Contact Accu-Sort Customer Service for more information.