The text of a manual · part 12 of 24
AccuLazr AL5010 Product Line Manual, pages 111 to 120
Pages 111 to 120 of 236
The original document is the PDF (13 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic AL5010
Page 111
Tracking Operation By utilizing the tracking capabilities of the AL5010, you can configure your application to monitor the progress of packages on the conveyance system. Tracking enables the AL5010 to track bar codes and the packages to which they belong. Your reader may scan more than one package with more than one code at a time within its read zone. Tracking allows the reader to accurately associate the correct bar code(s) with the correct packages. Typical tracking configurations use a tachometer to monitor conveyor speed. A simplified diagram of the required items for a tracking application is shown below:
Setup Functions for AL5010 Tracking Operation
Modify > Tracking – Tachometer (define tach type)
Modify > Tracking – AL5010 Mounting
Modify > Tracking – Transmit
Modify > Tracking – Track Config
Basic Tracking Setup Procedure To assure tracking accuracy, the distance from the Trigger Photoeye to the “X” scanning pattern must be measured and entered in the user interface. 1. To properly track-in the AL5010, drop a plumb bob from the center of the AS logo on the scan head. 2. Measure the distance (in inches) from the plumb bob to Trigger Photoeye. 3. Establish a connection with the AL5010. 4. Enter the value (in inches) into the Modify > Tracking > AL5010 Mounting > Trigger Reference Point field. IMPORTANT: After completing the basic tracking setup, see the advanced tracking procedure provided in the Modify > Tracking section. The Tracking > Trigger Reference Point, Closest Read Point and Furthest Read Point parameters must be properly set. (See Chapter 5.)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 112
Dual X-Scanning Operation In dual X-scanning applications, four AL5010 readers mounted side-by-side are used to create a dual “X” scanning patterns across the entire width of a conveyor. Four UMB brackets and four AL5010 readers can be used to create a dual-X scanning pattern.
Dual X-pattern can be created by four AL5010 readers
Dual X-Scanning Application A simple illustration of the required items for a double X-scanning configuration is shown below:
Setup Functions for AL5010 Controller
Modify > AL5010 Configuration - Reader Name (Controller)
Network Settings - # of Client Readers, IP address, and Group #
Setup Functions for AL5010 Clients
Modify > AL5010 Configuration - Reader Name (Client 1,2,3)
Network Settings – IP address and Group #
See Chapter 5 and online help for details on setting up a multi-reader network.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 113
Multiple-Reader Network Operation In multiple-reader applications, from 2 to 14 AL5010s can be networked together. A single AL5010 is configured as a Controller for a multiple-reader network. The AL5010 Controller gathers data from other AL5010s (up to 13, configured as clients) over an Ethernet network. The AL5010 Controller then collects and transfers the collected data over a serial communications or network link to the host. A simplified schematic diagram of the required items for a multiple-reader configuration is shown below:
Setup Functions for AL5010 Controller
Modify > AL5010 Configuration - Reader Name (Controller)
Network Settings - # of Client Readers, IP address, and Group #
Setup Functions for AL5010 Clients
Modify > AL5010 Configuration - Reader Name (Client 1,2,3)
Network Settings – IP address and Group #
See Chapter 5 and the online help for details on setting up a multi-reader network.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 114
106
AccuLazr™ AL5010 Product Line Manual
Operations
Scanning Array / Tunnel Operations The AL5010 can be set up with 1 controller and up to 13 clients in a single system and functioning in the same scanning area, the entire application is called a scanning array or tunnel. NOTICE: Due to the complexity of these applications, tunnel arrays are typically custom-engineered to your specifications. Setup Functions for AL5010 Controller
Modify > AL5010 Configuration - Reader Name (Controller)
Network Settings - # of Client Readers, IP address, and Group #
Setup Functions for AL5010 Clients
Modify > AL5010 Configuration - Reader Name (Client 1,2,3,4,5)
Network Settings – IP address and Group #
See Chapter 5 and the online help for details
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 115
7 Maintenance This chapter provides instructions for maintaining optimum performance and life for your AL5010. It provides specific information on:
Maintenance Procedures
Exterior Cleaning
Mounting Hardware Checks
Wiring Connection Checks
Tools and Materials Required Item
Description
Soft-bristle brush
For cleaning the reader’s exterior
Clean soft cloths
For cleaning the reader’s exterior
Cleaning solutions
Mild detergent solution for cleaning the reader’s exterior. 70% denatured alcohol, 30% de-ionized water solution for cleaning exit window
Soft cotton swabs or lint-free cloth
Use to clean reader’s exit window
Laser Shutoff Procedure In order to perform certain maintenance and service tasks, the reader’s lasers must be shut off in order to comply with all laser safety requirements. To shutoff the lasers: 1. Press the Test/Diagnostics button ( ! ) for 5 seconds. 2. The bar graph LEDs will light for the 5 second duration and then go out. 3. The lasers will then shut off. 4. After maintenance or service is complete, repeat the process to turn the lasers back on.
AL5010 Button and LEDs involved with Laser Shutoff
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 116
Maintenance Tasks Perform the maintenance tasks on an “as needed” basis to assure proper operation of the AL5010. Task schedule frequency depends upon the application environment conditions. It only requires a few minutes to complete each maintenance task.
Exterior Cleaning WARNING: Shut down the reader before performing this maintenance task. Do not stare into the reader’s exit window at the laser light. Avoid direct eye exposure. The laser light level does not constitute a health hazard, however staring at the laser light for prolonged periods could result in eye damage. WARNING: There are no user serviceable parts inside the AL5010. No internal components of the AL5010 are field replaceable units (FRUs). Opening the unit will potentially expose the user to emitted laser radiation, high voltage, and could reduce the effectiveness of the device’s IP rating. DO NOT REMOVE the faceplate from the scan head enclosure. Opening the AL5010 will also void the factory warranty. CAUTION: CLASS 3R LASER RADIATION. WHEN OPEN AVOID DIRECT EYE EXPOSURE. See warning above. CAUTION: Do not use any chemical on the reader that is unsafe for plastics, such as benzene, acetone, or similar products. Before performing this maintenance task, be sure to shutdown the reader. The exterior cleaning procedure may be performed without removing the reader from the mounting structure. 1. Turn off the reader’s lasers. 2. Clean the exterior (except the exit window) with a clean, soft-bristle brush. Be sure not to brush any dust, dirt, or debris onto the exit window. 3. Carefully remove any debris in or around the exit window. 4. Wipe the exterior (except the exit window) with a clean, soft cloth dampened slightly with a mild detergent solution. 5. The exit window should be cleaned after this task is completed.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 117
Cleaning the Exit Window WARNING: Shut down the reader before performing this maintenance task. Do not stare into the reader’s exit window at the laser light. Avoid direct eye exposure. The laser light level does not constitute a health hazard, however staring at the laser light for prolonged periods could result in eye damage. WARNING: There are no user serviceable parts inside the AL5010. No internal components of the AL5010 are field replaceable units (FRUs). Opening the unit will potentially expose the user to emitted Class 3 laser radiation, high voltage, and could reduce the effectiveness of the device’s IP rating. DO NOT REMOVE the faceplate from the scan head enclosure. Opening the AL5010 will also void the factory warranty. CAUTION: CLASS 3R LASER RADIATION. WHEN OPEN AVOID DIRECT EYE EXPOSURE. See warning above. CAUTION: Never apply cleaning solution directly to the exit window. Always apply the solution to a cloth, and then the cloth to the window. Do not use any chemical on the reader that is unsafe for plastics, such as benzene, acetone, or similar products. The exit window cleaning procedure may be performed without removing the reader from the mounting structure if it is possible to do so. 1. Turn off the reader’s lasers. 2. Follow the exterior cleaning procedure before cleaning the exit window. 3. Check the exit window surface for any dust, dirt, or smudges. If the window needs to be cleaned, proceed to Step 4. 4. Make a solution of seven parts denatured alcohol and three parts water. 5. Apply the cleaning solution to a cotton swab or lint-free cloth. 6. Apply the cleaning solution to the exit window. 7. Remove any streaks or remaining moisture from the exit window with a dry, soft, lint-free cloth or lens paper. 8. Turn the reader’s lasers back on. 9. Verify reader operation. Follow the Operations Checklist procedure in Chapter 5.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 118
Cleaning the Trigger Photoeye If your application uses the photoeye option as a hardware trigger, be sure to clean the photoeye periodically as outlined below. 1. Turn off the product transport. 2. Turn off the reader’s lasers. 3. Clean the photoeye’s lens using the denatured alcohol solution and a cotton swab or lens paper. Check the reflector on the opposite side of the transport. Clean as necessary. 4. Verify photoeye operation.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 119
Cleaning the Tachometer If your application uses the tachometer option for tracking purposes, be sure to clean the tachometer wheels periodically as outlined below. 1. Turn off the product transport. 2. Turn off the reader’s lasers. 3. Using a clean, soft cloth, wipe the wheels of the tachometer clean using a mild detergent solution. 4. Before restarting the system, be sure the tachometer is making good contact with the product transport. 5. Verify tachometer operation.
Tighten Mounting Hardware 1. Check all reader mounting hardware. Tighten as necessary. Do not over-tighten. Be sure not to disturb the reader’s alignment as it relates to the product transport. 2. Check the mounting hardware of the photoeye and tachometer (if these options are being used). Tighten as necessary. Do not over-tighten.
Checking Interface Module Connections All wiring connections are typically made to an interface module. (See Chapter 3, Installation.) 1. Check all cord grips. Tighten as necessary. Do not over-tighten. 2. If a cord seems loose, also check the wiring connections to the terminal blocks. Tighten as necessary. Do not over-tighten. 3. Check all cabling/conduit for signs of wear/damage. Repair/replace any damaged cable connections as necessary.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 120
112
Maintenance
AccuLazr™ AL5010 Product Line Manual
Verify Reader Operation Follow the Operations Checklist procedure defined in Chapter 5. If the reader parameters were changed to read bar codes other than the factory defaults, simply use a good quality bar code to assist in verifying proper operations. There is no need to return the reader to the default parameters to perform this test.
Verify Photoeye Operation 1. Block the photoeye beam to confirm it is aligned properly with the reflector. 2. If the LED on the photoeye changes status, the photoeye is functioning properly.
Trigger Photoeye – Status LED Location 3. Verify that the Trigger LED on reader is green when photoeye beam is blocked. 4. If the photoeye’s LED does not change status, adjust the photoeye so that it is properly aligned with the reflector. 5. If the Trigger LED on the reader is not green when the photoeye’s beam is blocked, check the cabling between the photoeye and reader mounting base for damage.
Verify Tachometer Operation There are two ways to verify tachometer operations. Use AccuLazr User Interface 1. Establish a connection with the reader. 2. Go to Diagnostics > Monitor. 3. Verify the Belt Speed is accurate when the conveyor is running. Use Tach LED in Enhanced Interface Module 1. Locate the Tach LED. 2. Slowly spin the tachometer wheel. 3. Verifying the tach LED in the mounting base is flashing.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net