Page 91
Diagnostics > Monitor Use the Diagnostics > Monitor as the primary tool to monitor the reader's operation and bar code readability in real-time. Status indicators and vital statistics appear on a single screen, enabling you to effectively and efficiently detect and troubleshoot any problems that may occur. The Monitor is a Java application and requires Java and the appropriate browser plug-in.
See also: Diagnostics > Monitor in Appendix C.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 92
Diagnostics > Log Viewer The Diagnostics > Log Viewer lets you review the performance logs saved by the reader. The three most commonly viewed logs are available by selecting one of the three buttons: •
Read Rate
•
System Counters
•
Message Log
You can also enter a log request in the Command field. For example: DISPENET will provide Ethernet data. The log view field remains empty until you select a button or enter a command. To determine which log is currently being shown in the log viewer, the log's name is shown just below the words log view in the window. For additional information and field descriptions, see Diagnostics > Log Viewer in Appendix C. To use commands to view a log: 1. Enter a command in the Log Viewer Command field without using spaces (i.e., DISPCOUNTERS, DISPMSGLOG, etc.) 2. Click Send Command. 3. Log Viewer displays the most current information for the log you requested. 4. Click Clear to empty the Log Viewer. 0. Read Rate Log View Use the Read Rate Log View to see a summary of the reader’s overall performance. To open the Read Rate Log View: 1. Click Read Rate, or 2. Enter DISPREADRATE in the command field. Click Send Command. 3. The Read Rate log is shown in the viewer. 4. Click Clear to empty the viewer and display another log. 0. Overall Read Rate Statistics The Read Rate Log Viewer provides information on the overall read rate. Total Boxes
Total number of triggers.
Good Boxes
A good box is a box with all required codes. This counter is the number of good boxes along with the percentage of the total boxes that were good.
Partial Boxes
A partial box is a box were some, but not all required codes were read. This only applies when the reader is configured to read multiple codes each trigger.
Bad Boxes
A bad box is a box where no codes were read.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 93
Read Rate Counters by Laser The Read Rate Log Viewer also provides performance information on each laser. In order to provide diagnostics on the performance of each laser, the percentage references here are the percentage of the total codes read by the particular laser, NOT the percentage of the total packages read by that laser. Total Codes
Total number of bar codes read.
Laser#x
Total number of bar codes read by the particular laser
For a reader configured as a Controller in a multi-reader network, this command also provides counters for the number of bar codes read, by laser, for each reader client. The clients are identified by their reader name as assigned in Modify > Configuration. REMEMBER: Not every reader is configured with two lasers.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 94
Counters Log View Use the Counters Log View to display a number of values and counters that indicate whether the reader is configured and operating properly. To open the System Counters Log View: 1. Click Counters, or 2. Enter DISPCOUNTS in the command field. Click Send Command. 3. The system counters log is shown in the viewer. 4. Click Clear to empty the viewer and display another log. 0. Scan Rate and Belt Speed System Counters Scan Rate
This is the total number of scans/second that the reader is reading. Note the this number does NOT take into account “laser toggling” if it is enabled. If “laser toggling” is enabled, the effective scan rate for any laser is half of this value.
Belt Speed (Tracking)
Speed of the belt (in ft/min) as measured by the tachometer.
Bar Code System Counters Triggers
Total number of packages based on the trigger signal. In selftrigger mode, this will match the number of good reads.
Good Reads
Total number of bar codes read and transmitted. If the reader is set up to read multiple bar codes each trigger, this counter is incremented for each bar code read.
No Reads
Total number of bar codes that were not read.
Mult Codes
Total number of instances where more bar codes of a specific type were read than expected. This counter will also increment, regardless of whether the reader is configured to report “multiple codes” as an error.
Match Codes
Total number of bar codes that matched any of the Match Code criteria.
Bad ModChk
Total number of bar codes that were rejected due to an invalid Mod Check.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 95
Error Counters Xfter Ovrflw
Transfer Overflow. This counts the number of codes that were lost due to an overflow in the transfer buffer between the Decode/DSP processor and the reader/ARM processor.
Xfer BadLen
Transfer Bad Length. Number of codes in the transfer buffer than contained an invalid length, indicating some sort of memory corruption.
QData@TX
Queue Data at Transmit (non-tracking). This counter indicates that the reader had not completed processing all of the scan data at the user-specified transmit time. This will only happen if the “transmit time” parameter is set to a value other than zero. This does not necessarily indicate an error, but does indicate that either the transmit time is too short or the reader is seeing a lot of data which may be the result of too much background noise.
QData@Trig
Queue Data at Trigger (non-tracking). This counter indicates that the reader had not completed processing all of the scan data prior to the start of the next trigger. This typically can only happen when the "transmit time” parameter is set to zero; although it can also happen in conjunction with a Force Transmit. As with the Queue Data at Transmit counter, this does not necessarily indicate an error, but it likely indicates that the reader is seeing a lot of data which may be the result of too much background noise.
ForcedTx
Forced Transmit (non-tracking). A forced transmit indicates that the start of trigger occurred before the specified transmit delay time had expired.
Lost Codes
Lost Codes (tracking). If a bar code cannot be placed onto any package while in tracking, the code is “lost” and this counter is incremented. Lost codes are also reported in the Monitor message window. Lost code occurrences typically indicate tracking parameters need to be adjusted.
Missed Tx
Missed Transmit (tracking). If a bar code is decoded after the message for that package has been transmitted, the Missed Transmit counter is incremented.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 96
Decode/DSP Counters DSP Codes
Count of the number of bar codes decoded, per laser, by the DSP.
Scan Ints
Number of scan interrupts detected by the DSP.
Queue Size
Current size of the scan data queue within the DSP. This value changes dynamically.
Num Cluster
Current number of DRX clusters in use by the DSP. This value changes dynamically.
Bad Scan
Count of the number of scans in which the data contained formatting errors.
Pipe Error
Count of internal errors on the transfer of scan data from the scan data buffer.
Full Scans
Number of times a scan could not be added to the scan data buffer because the maximum number of scans was exceeded.
Mem Full
Number of times a scan could not be added to the scan data buffer because the memory was full.
ScanTooLong
Number of times a scan was skipped because it contained too many transitions.
Max Clusters
Number of times, the maximum number of DRX clusters was exceeded.
ARM and DSP Restarts Counters ARM Restarts
Number of times the ARM processor has restarted. This typically means the hardware watchdog timer expired causing the ARM processor to restart.
DSP Restarts
Number of times the DSP processor has been restarted. Typically, this happens if the ARM suspects the DSP has “locked up” for any reason.
Message Log View The Message Log View contains various text messages that have been logged by the reader software. The messages contained in this log typically reflect significant events. To open the Message Log View: 1. Click Message Log, or 2. Enter DISPMSGLOG in the command field. Click Send Command. 3. The message log is shown in the viewer. 4. Click Clear to empty the viewer and display another log. 0.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 97
Command There are several commands that you can use to display reader parameters and diagnostic information. Commands can be sent from the Command field on the Log Viewer. Commands may also be sent from a terminal interface, such as a TELNET connection to the reader. Log Viewer Commands
Definition
CLEAR ALL
Clears all information from the Message Monitor.
DISP COUNTERS
Display the System Counter log view.
DISP ENET
Display the Ethernet interface status, including MAC address.
DISP MSGLOG
Display the Message log view.
DISP READRATE
Display the Read Rate log view.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 98
90
AccuLazr™ AL5010 Product Line Manual
Setup
Diagnostics > Update Firmware Use Diagnostics > Update Firmware to reload the reader firmware. For additional information and field descriptions, see Diagnostics > Update Firmware in Appendix C. CAUTION: This function should only be performed under the guidance of Accu-Sort Technical Support.
To Extract Image 1. Click Extract Image. 2. In Save as window, save the image (*.as) files to your computer. The graphic on-screen indicates Extract Image is in-process.
3. A message will appear when Extract Image is complete. 0. To Burn Flash 1. Click Burn Flash. 2. In Open window, open an image file (*.as) to burn to flash. The graphic on-screen indicates Burn Flash is in-process.
3. A message will appear when Burn Flash is complete. 0.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 99
6 Operations This chapter provides details on how the AL5010 bar code scanning solutions function during normal operation. It also outlines how you can verify optimal performance through several methods:
Become more familiar with your application
Step-by-step start-up operations checklist
Status Indicator LEDs
AL5010 Reader
AL5010 Interface Module
Diagnostics to confirm normal operations
After configuring your AL5010 reader using the browser-based setup application, use the operations checklist to verify normal operations.
First-time Startup On initial power-up, the AL5010 performs a series of self-diagnostic and LED tests. The complete power-up sequence takes less than 20 seconds. When the STATUS LED flashes and turns a steady green the power-up sequence is complete. The AL5010 is now operational. NOTE: When an application uses multiple AL5010 readers, you can provide each reader with a unique reader name using the browser-based setup application. This makes it easier to keep track of reader parameter changes when working with several readers on a network. (See Chapter 5.)
Default Parameters The reader is shipped from the factory with these defaults:
Connection Mode: Setup Cable
Reader Name: AL5010
Control Panel Buttons Enabled
Code 128 (10-30 characters)
IP address 192.168.3.100
Perform the following setup procedure using these defaults or configure your AL5010 with your application’s parameters using the browser-based setup application.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 100
First-time Setup Every application is unique. AL5010 is designed for ease-of-setup, allowing you to program the reader to fit your application seamlessly. A browser-based setup application on your laptop/desktop computer is the tool you will use to define operating parameters, set bar code type / length, and construct output messages, including filtering, stripping and padding capabilities. AccuLazr’s user interface enables you to easily configure, finetune, and monitor your AL5010’s operations. AL5010 provides ease-of-use regardless of your experience with bar code readers. A beginner follows basic setup procedures for a standard configuration. If you are more experienced, use the advanced setup features that allow access to more complex options. First-time Setup Procedure To setup your AL5010 bar code reader: 1. Connect an RJ45 Ethernet cable to the AL5010. 2. Connect the other end of the cable to your laptop/desktop computer. 3. Apply power to AL5010. 4. Set configuration parameters for bar code symbologies, trigger, tracking, and communications (serial, Ethernet, and I/O). 5. Check operations using the Test Mode.
Check Operations using Test Mode NOTE: Perform the following test using a bar code that matches the default parameters. Or you may wish to perform this test after configuring the AL5010 to your specifications. If the default parameters have been changed, you must enable the control panel buttons and the other parameters listed on page 96. See Chapter 5, Modify > Configuration and Modify > Bar Code Setup. To quickly check the operation of an AL5010: 1. Apply power to the AL5010. 2. Position a test bar code symbol approximately 20 inches (0.5 meter) from the reader. Skew the bar code symbol slightly. 3. Press the Test/Diagnostics button on the control panel to initiate test. 4. The laser(s) should be scanning continuously during normal operations. (Observe the laser safety warnings in Chapter 2. If it becomes necessary to shutoff the laser(s), follow procedure outlined in Chapter 6.) 5. Observe the bar graph LEDs on the AL5010 control panel. The read LED will blink GREEN if it reads a bar code, or RED if it doesn’t. 6. Connect your PC via the network.