The text of a manual · part 1 of 24
AccuLazr AL5010 Product Line Manual, pages 1 to 10
Pages 1 to 10 of 236
The original document is the PDF (13 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic AL5010
Page 1
AL5010
Product Line Manual
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 2
AccuLazr™ AL5010 Product Line Manual
PN 1000068393 2.1 | CMS 11-0023 | 2013.01.31 | RAY
Document Revision Control This document is under revision control in accordance with Datalogic’s Quality System. Any addenda or other documents associated with this manual are under separate revision controls. A revision number is changed by 0.1 whenever technical information is changed or added to a document.
Copyright Information Copyright © 2011-2012 DATALOGIC. All rights reserved. No part of this document is to be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, or by an information storage and retrieval system without prior written consent of Datalogic Systems, Inc. All drawings and specifications contained in this manual are the property of Datalogic Systems, Inc. and shall not be reproduced, copied or used in whole or in part as the basis for the sale or manufacture of products without the written permission. ®
Datalogic and DRX are registered trademarks and the AS logotype, 1-800™ BAR-CODE is a trademark of Datalogic. All other company or product names are mentioned for purposes of identification only, and may be trademarks of their respective owners. Disclaimer Information
The information contained in this manual is subject to change without notice. Supplemental information or documentation may be required for certain applications or usage. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Datalogic cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Datalogic with respect to use of information, circuits, equipment, or software described in this manual. In no event will DATALOGIC. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
Datalogic 511 School House Rd. Telford, PA 18969 1-800-BAR-CODE™
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 3
AccuLazr™ AL5010 Product Line Manuals
Contents
Contents Preface
Intended Audience ......................................................................................... vii Thank You...................................................................................................... vii Overview of Contents.................................................................................... viii Other Sources of Information........................................................................ viii Conventions .................................................................................................. viii Customer Service ......................................................................................... viii
1 Introduction
AL5010 Product Line Overview .......................................................................9 The AL5010 Scan Head ................................................................................10 The AL5010 Mounting Base ..........................................................................10 The AL5010 Interface Module .......................................................................11 AccuLazr™ User Interface.............................................................................12 Typical AL5010 Mid-Range Bar Code Reading Applications ........................13 Options and Accessories ...............................................................................14
2 Safety
Symbols .........................................................................................................15 General Precautions ......................................................................................16 Unpacking, Mounting and Installation Recommendations ............................16 Compliance Requirements ............................................................................17 Electrical Safety .............................................................................................17 Electrical Grounding Requirements ...............................................................18 Electrostatic Discharge ..................................................................................18 Basic Rules for ESD Control..........................................................................18 Laser Safety...................................................................................................19 Safety Labels and Locations..........................................................................20
3 Mechanical Installation
Prerequisites ..................................................................................................21 Tools Required...............................................................................................21 Additional Information ....................................................................................21 Unpacking Instructions ..................................................................................21 Installation Sequence.....................................................................................22 Orientation Considerations ............................................................................23 Read Range...................................................................................................23 Bar Code Orientation to Scanning Area .......................................................24 General Mounting Guidelines ........................................................................25 Reader Positioning.........................................................................................25 Dimensions and Clearances..........................................................................26 Attaching the Mounting Base.........................................................................26 Attaching the Universal Mounting Bracket (UMB) .........................................27 Installing an AL5010 Scan Head ...................................................................28 Mounting the Trigger Photoeye .....................................................................29 Mounting the Tachometer ..............................................................................30 Mounting the Interface Module ......................................................................31 Mounting the I/O Modules..............................................................................34
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net iii
Page 4
iv
AccuLazr™ AL5010 Product Line Manuals
Contents
4 Electrical Installation
Prerequisites ..................................................................................................37 Tools Required.............................................................................................. 37 Additional Information ....................................................................................37 Installation Sequence(s) ................................................................................38 Installing Multiple Readers.............................................................................38 General Electrical Installation Guidelines and Precautions...........................39 Cable and Conduit Connections ....................................................................40 Wiring the AL5010 Interface Modules............................................................41 Power Requirements .....................................................................................45 Power Supply Connections............................................................................45 Trigger Connections.......................................................................................46 Tachometer Connections...............................................................................47 Serial Communications Connections (COM1 and COM2) ............................48 Ethernet Communications Connections ........................................................50 I/O Module Connections ................................................................................51 DeviceNet ......................................................................................................53 Profibus ..........................................................................................................53 Connecting the AL5010 .................................................................................53 Wiring to the AL5010 without an Interface Module........................................54 Check Installation...........................................................................................55
5 Setup
Getting Started...............................................................................................57 AccuLazr User Interface Basics.....................................................................60 Getting Help ...................................................................................................60 Modify Settings ..............................................................................................61 Configuration ...........................................................................................62 Bar Codes................................................................................................63 Modulo Checks........................................................................................65 Stripping/Padding ....................................................................................66 Match Codes ...........................................................................................67 Serial Communications ...........................................................................68 Network ...................................................................................................71 Trigger .....................................................................................................74 Relay .......................................................................................................75 Tracking...................................................................................................76 FAST Monitor™.......................................................................................77 Advanced.................................................................................................79 Save / Retrieve ..............................................................................................80 Diagnostics ....................................................................................................81 Monitor.....................................................................................................82 Log Viewer...............................................................................................83 Update Firmware.....................................................................................90
6 Operations
First-time Startup ...........................................................................................91 Default Parameters ........................................................................................91 First-time Setup..............................................................................................92 Check Operations using Test Mode ..............................................................92 Operations Checklist......................................................................................93 Control Panel Indicators ................................................................................94 Backup / Restore Procedures........................................................................99 Checking Operations with User Interface ....................................................100
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 5
AccuLazr™ AL5010 Product Line Manuals
Contents
Standalone Operation ..................................................................................102 Tracking Operation ......................................................................................103 Dual X-Scanning Operation .........................................................................104 Multiple-Reader Network Operation ............................................................105 Scanning Array / Tunnel Operation .............................................................106
7 Maintenance
Laser Shutoff Procedure ..............................................................................107 Maintenance Tasks......................................................................................108 Cleaning Exit Window ..................................................................................109 Cleaning Trigger Photoeye ..........................................................................110 Cleaning Tachometer...................................................................................110 Tighten Mounting Hardware ........................................................................111 Checking Interface Module Connections.....................................................111 Verify Reader Operation ..............................................................................112 Verify Photoeye Operation...........................................................................112 Verify Tachometer Operation.......................................................................112
8 Troubleshooting
Test Mode ....................................................................................................113 Status Indicators ..........................................................................................113 Control Panel Indicators ..............................................................................114 Diagnostics ..................................................................................................117 Log Viewer ...................................................................................................120 Update Firmware .........................................................................................126 Troubleshooting Tables ..............................................................................131
9 Service
Replacement Procedures ............................................................................129 AL5010 Field Replaceable Units (FRUs) Spare Parts ...............................130 Interface Module FRU Spare Parts .............................................................131
Appendices A Specifications
Al5010 Technical Specifications ..................................................................133 Basic Interface Module Technical Specifications ........................................133 Enhanced Interface Module Technical Specifications ................................134 Power Supply...............................................................................................134 Output Modules............................................................................................135 Input Modules ..............................................................................................135 Certifications ................................................................................................136
B Read Charts
AL5010 Read Charts ...................................................................................137
C User Interface
AccuLazr User Interface ..............................................................................149 Modify Settings ............................................................................................150 Configuration .........................................................................................151
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net v
Page 6
vi
AccuLazr™ AL5010 Product Line Manuals
Contents
Bar Codes..............................................................................................153 Modulo Checks......................................................................................155 Stripping/Padding ..................................................................................156 Match Code Patterns.............................................................................157 Serial Communications .........................................................................161 Network .................................................................................................166 Trigger ...................................................................................................170 Relay .....................................................................................................172 Tracking.................................................................................................174 FAST Monitor™.....................................................................................176 Advanced...............................................................................................177 Save / Retrieve ............................................................................................179 Diagnostics ..................................................................................................181 Monitor...................................................................................................182 Log Viewer.............................................................................................184 Update Firmware...................................................................................185
D Networking Guide
.................................................................................................................... 187
E FAST Monitor Configuration
.....................................................................................................................207
F Installation Drawings
.....................................................................................................................209
G Test Label for Adjustable Raster Setup .....................................................................................................................231
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 7
!""#$%&'()!$*+,+)-'./#"0)$123)4%2#%56! !
"#$%&'$! !
-'37%"3) *$+',-$!.,!./$!!""#$%&'()!$*+,+)-'./#"0)$123)4%2#%5!%#,-!0''123,#.! 345.$-56!78'9!:/)5!15$#!-&81&+!)8'+1;$5!./$!)8%,#-&.),8!4,1!8$$;!.,! )8.$<#&.$!$%%$'.)($+4!./$!!$*+,+)6%')7./3)83%/3'!=)./!4,1#!&>>+)'&.),89!7.! ',8.&)85!;$.&)+$;!)8%,#-&.),8!&?,1.!./$!%,++,=)8<@! !!
"#,;1'.!%$&.1#$56!'&>&?)+).)$56!5>$')%)'&.),85!&8;!&''$55,#)$5!
!!
3&%$.4!)8%,#-&.),8!
!!
785.&++&.),8!<1);$+)8$5!&8;!>#,'$;1#$5!!
!!
A,8%)<1#)8<!./$!0BCDED!%,#!4,1#!&>>+)'&.),8!!
!!
F&)8.$8&8'$!&8;!:#,1?+$5/,,.)8<!
:/)5!>#$%&'$!$G>+&)85!/,=!./)5!15$#!-&81&+!)5!,#<&8)H$;!&8;!)8.#,;1'$5! ,./$#!5,1#'$5!,%!)8%,#-&.),8!./&.!4,1!=)++!%)8;!15$%1+9!
82032/3/)!#/132"3) I,1!5/,1+;!/&($!&!?&5)'!18;$#5.&8;)8<!,%!?&#!',;$!5'&88)8<9!JK1)>-$8.! )85.&++$#5!-15.!?$!%&-)+)&#!=)./!5.&8;&#;!=)#)8<!.$'/8)K1$5!&8;!.$#-)8,+,<49! L$'&15$!./$!0''1B&H#!15$#!)8.$#%&'$!5,%.=&#$!#185!,8!&!=$?!?#,=5$#!)8!./$! F)'#,5,%.M!*)8;,=5M!$8()#,8-$8.6!4,1!5/,1+;!N8,=!/,=!.,!15$!&!-,15$6! '/,,5$!',--&8;56!&8;!=,#N!=)./!=)8;,=5!&8;!;)&+,<!?,G$59! :/)5!-&81&+!',8.&)85!5,-$!.$#-5!./&.!-&4!?$!18%&-)+)	!!O5$!./$!<+,55! &.!./$!?&'N!,%!./)5!-&81&+!%,#!&55)5.&8'$9!
9:%2;)<.#) :/&8N!4,1!%,#!15)8<!&8!0BCDED!?&#!',;$!5'&88)8<!5,+1.),8!&8;!./)5!-&81&+9!! *$!(&+1$!4,1#!',--$8.5!&8;!%$$;?&'N9!P$$+!%#$$!.,!+$.!15!N8,=!=/&.!4,1! +)N$!,#!;)5+)N$!&?,1.!0BCDED!Q,#!./)5!-&81&+R!?4!$2-&)+)8<!15!&.! "#$%&'()%*')"%#&(+,-')'.%/"0&0%*9!! I,1!'&8!&+5,!-&)+!4,1#!',--$8.5!.,!,1#!',#>,#&.$!/$&;K1&#.$#5!&;;#$55!,#! '&++!15!;)#$'.+4!&.!E2SDD2L0T2AUVJW!,#!QXECR!YXZ2D[SE9!
! =>9?@):/$#$!-&4!?$!&;;).),8&+!-&.$#)&+!./&.!=&5!8,.!&(&)+&?+$!=/$8!./)5! >#,;1'.!-&81&+!=&5!>#,;1'$;9!:,!+$!)%!./$#$!)5!&!;,'1-$8.&.),8!1>;&.$6! <,!.,!,1#!=$?!5).$\5!',##$5>,8;)8<!>#,;1'.!>&<$!&. Datalogic website.
! !
>0:3')A.#'"36).7)827.'B%01.2) I,1!'&8!'/,,5$!%#,-!-&84!)8%,#-&.),8!5,1#'$56!)8'+1;)8<!;,'1-$8.&.),86! .#&)8)8<6!&8;!51>>,#.!5$#()'$56!.,!)8'#$&5$!4,1#!N8,=+$;<$!&8;! 18;$#5.&8;)8<!,%!./$!0BCDED!?&#!',;$!5'&88)8<!5,+1.),859!7%!./)5!-&81&+! #$%$#5!4,1!.,!,./$#!;,'1-$8.&.),86!15$!,8+4!./$!+&.$5.!($#5),85!18+$55! ,./$#=)5$!5>$')%)$;9!
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
())!
Page 8
viii
AccuLazr™ AL5010 Product Line Manuals
Preface
Conventions WARNINGS or CAUTIONS: This symbol identifies a hazard or procedure that, if incorrectly performed, could cause personal injury or result in equipment damage. It is also used to bring the user’s attention to details that are considered IMPORTANT. HIGH VOLTAGE CAUTION: This symbol alerts the user they are about to perform an action involving, either a dangerous level of voltage, or to warn against an action that could result in damage to devices or electrical shock. LASER CAUTION: This symbol alerts the user they are about to perform an action involving possible exposure to laser light radiation. ESD CAUTION: This symbol identifies a procedure that requires you take measures to prevent Electrostatic Discharge (ESD) e.g., use an ESD wrist strap. Circuit boards are most at risk. Please follow ESD procedures. NOTES: This symbol draws attention to details or procedures that may be useful in improving, maintaining, or enhancing the performance of the hardware or software being discussed. NOTE REGARDING DIMENSIONAL REFERENCES: This manual provides all dimensional references in inches and in most cases Metric referenced in brackets, for example 10 inches [254 mm].
Customer Service Training Accu-Sort Systems offers a complete set of training courses to help you and your staff get the most out of your investment. We can help you develop a training plan that provides thorough training for both your project team and your end users. We will work with you to organize courses appropriate to your job or area of responsibility. Training professionals can show you how to plan your training throughout the implementation process so that the right amount of information is delivered to key people when they need it the most. You can attend courses at our training center, or you can arrange for our trainers to teach at your facility. In addition, we can tailor standard courses or develop custom courses to meet your needs.
Support From on–site support to central support, our team of experienced professionals provides the help and information you need to keep your equipment working for you. This team includes your Account Manager and Accu-Sort’s large staff of support specialists with expertise in your business area and managing your hardware and software environment. NOTE: If you have any problems or questions that require Accu-Sort's assistance, direct your calls to Customer Service at 1-800-BAR-CODE™ or (215) 723-0981.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 9
1 Introduction This chapter presents an introductory description of the AccuLazr™ AL5010 laser barcode scanner product line including: AL5010 Product Line Overview AccuLazr User Interface
AL5010 Product Line Overview The AL5010 line of laser barcode readers is designed with industrial and manufacturing applications in mind, providing high-speed scanning and high reliability in a rugged industrial enclosure. The entire AL5010 product line offers a large depth of field that provides accurate barcode reading from as little as 4 inches up to 48 inches. The AccuLazr AL5010 Mid-Range Laser Barcode Readers include: AL5010 Scan Head AL5010 Mounting Base AccuLazr Interface Module (optional) Power Supply Module (optional)
AL5010 Barcode Reader
AccuLazr Basic Interface Module
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 10
AL5010 Scan Head The AL5010 Scan Head incorporates the optics and laser module(s) for scanning barcodes as well as the decoding engine and parameter storage module. The control panel provides several LED status indicators and three function buttons.
There are five models of the AL5010 Scan Head (each available with optional adjustable raster): One-laser models for standard and high-density Two-laser models for standard, near-focus high-density and high-density An optional Adjustable Raster (adjustable up to 20-degrees above or below 0-degrees, variable DOF) is available in the existing scan head housing. No bolt-on additions are required.
AL5010 Mounting Base The AL5010 Mounting Base provides for the mounting of the AL5010 as well as the wiring interface between the scan head and AccuLazr Interface Module. It includes a parameter storage module that enables parameters to be uploaded/downloaded with the ‘hot-swappable’ scan head.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net