Page 45

Interface Features

RS-232 Interface Features, cont. START/END BAUD RATE

BAR CODE

57600 Baud

115200 Baud

Product Reference Guide

3-11

Page 46

Interface Related Features

RS-232 Interface Features, cont. START/END STATE

BAR CODE

7 Data Bits

8 Data Bits

1 Stop Bit

2 Stop Bits

Parity = None

3-12

PowerScan® 7000BT SRI

Page 47

Interface Features

RS-232 Interface Features, cont. START/END STATE

BAR CODE

Parity = Even

Parity = Odd

Product Reference Guide

3-13

Page 48

Interface Related Features

RS-232 Interface Features, cont. Hardware Flow Control Disable Hardware Control, The scanner transmits to the host regardless of any activity on the CTS line. Enable CTS Flow Control, The CTS signal controls transmission of data to the host. Enable CTS Scan Control, The CTS line must be active for the scanner to read and transmit data. While the CTS line is inactive, the scanner remains in a host-disabled state; following a successful label transmission, the CTS signal must transition to inactive and then to active to enable scanning for the next label.

Intercharacter Delay This delay is inserted after each data character transmitted. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make the system work properly.

Software Flow Control Disables/Enables software control using XON/XOFF characters.

3-14

PowerScan® 7000BT SRI

Page 49

Interface Features

RS-232 Interface Features, cont. START/END STATE

BAR CODE

Disable Hardware Control

Enable CTS Flow Control

Enable CTS Scan Control

Inter-Char Delay = No Delay

Interchar Delay = 10 msec

Interchar Delay = 20 msec

Product Reference Guide

3-15

Page 50

Interface Related Features

RS-232 Interface Features, cont. START/END STATE

BAR CODE

Interchar Delay = 30 msec

Interchar Delay = 40 msec

Interchar Delay = 50 msec

Interchar Delay = 60 msec

Interchar Delay = 70 msec

Interchar Delay = 80 msec

3-16

PowerScan® 7000BT SRI

Page 51

Interface Features

RS-232 Interface Features, cont. START/END STATE

BAR CODE

Interchar Delay = 90 msec

Disable Software Flow Control

Enable Software Flow Control

Product Reference Guide

3-17

Page 52

Interface Related Features

RS-232 Interface Features, cont. Host Echo When enabled, this feature passes all data through the scanner to the host as it comes in. This feature is used for applications where “daisy chaining” of RS-232 devices onto the same cable is necessary. If, for example, one of the devices in the chain is a terminal where someone is entering data while another person is simultaneously scanning a bar code requiring transmission to the host, the scanner will wait for the RS-232 channel to be quiet for a specified period of time (set via RS-232 Host Echo Quiet Interval). The scanner can be set to observe this delay before sending its data in order to avoid RS-232 transmission conflicts.

Host Echo Quiet Interval This setting specifies the time interval of RS-232 channel inactivity which must transpire before the scanner will break the host echo loop to transmit the bar code data that has just been scanned to the host.

Signal Voltage: Normal/TTL Specifies whether the RS-232 interface provides TTL levels on the output pins TxD and RTS.

RS-232 Invert Enables/disables inversion of RS-232 TXD and RXD signals.

3-18

PowerScan® 7000BT SRI

Page 53

Interface Features

RS-232 Interface Features, cont. START/END STATE

BAR CODE

Disable Host Echo

Enable Host Echo

Host Echo Quiet Interval = 0msec

Host Echo Quiet Interval = 10msec

Host Echo Quiet Interval = 20msec

Host Echo Quiet Interval = 30msec

Product Reference Guide

3-19

Page 54

Interface Related Features

RS-232 Interface Features, cont. START/END STATE

BAR CODE

Host Echo Quiet Interval = 40msec

Host Echo Quiet Interval = 50msec

Host Echo Quiet Interval = 60msec

Host Echo Quiet Interval = 70msec

Host Echo Quiet Interval =80msec

Host Echo Quiet Interval = 90msec

Host Echo Quiet Interval = 100msec

3-20