Page 265

Appendix H

Beeper/LED Indications Beep Indications Beep Type

Description

Behavior

Acknowledge (ACK) Label

A label has been sent to the Base Station, which has accepted the data and responded. Control via ACK NAK Options.

1 beep. Duration, frequency and volume vary, since these are all configurable for this feature.

Label Rejected

Label data sent is rejected by the Base Station (responds with NAK). Control via ACK NAK Options.

2 beeps at low frequency.

Transmission Error

A label has been sent to but not received by the Base Station (ACK timeout occurred). Control via Transmission Failure Indication.

Beep will sound High-low-high-low.

Link Successful

The Linking process has completed successfully between a scanner and Base Station (or PC).

Beep will sound Low-med-high.

Link Unsuccessful

The Linking process has completed (timed out) without connecting to a Base (or PC).

Beep will sound High-low-high-low.

Product Reference Guide

H-1

Page 266

Beep Type

Description

Behavior

Unlink

The scanner has unlinked from the Base Station.

Beep will sound High-medium-low.

Paging

Base Station is paging the scanner.

5 beeps at high volume and current Good Read Beep Frequency setting.

BT Scanner FRU

The scanner will sound this upon detecting aField Replaceable Unit (FRU) error at startup.

1 long error tonea.

Disconnect

Sounds when the scanner disconnects from the Base Station due to out of range, low power, etc. Control via "BT Disconnect Beep" on page 5-12

Beep will sound High-medium-low. (Same as Unlink)

Good Read Disconnected

A label is read while disconnected, and ACK Timeout is disabled.

1 long beep at low frequency.

Good Read Unlinked

A label is read while unlinked.

Leash mode

The Handheld has disconnected, and BT Leash Beep is enabled.

Beep will sound High-low-high-low. Beep will sound at high volume, low frequency for the count specified in BT Leash Beep a. Upon hearing a long error tone at startup, press the trigger to hear the FRU error beep sequence described in Error Codes.

H-2

PowerScan® 7000BT SRI

Page 267

LED Indications

LED Indications Applies to: LED Indication

Linking in progress

Behavior

Yellow LED blinks at 2 Hz

Base Station

Scanner

YES

YES

NO

YES

Yellow LED blinks as long as the trigger is pulled while scanner is enabled. Exceptions are:

Low battery

-If scanner is disabled, the low battery LED will not occur because the trigger is also disabled. -The BT transmit indication will override this indication, i.e., when a decode occurs while battery is low, the BT transmit LED will interrupt (stop) the low battery LED.

Disconnected

LEDs off

YES

YES

Unlinked

LEDs off

YES

YES

BT transmission in progress

Flash yellow LED at 50 Hz while transmitting.

YES

YES

Paging

Yellow LED blinks at the same rate as the paging beep (1 hz)

YES

YES

BT Scanner FRU indication

See the topic Error Codes.

NO

YES

BT Base Station FRU indication

See the topic Error Codes.

YES

NO

Disabled indication

Green LED blinks once a second while disabled

NO

YES

Battery charge in progress

Green LED blinks once a second while charging

YES

NO

Product Reference Guide

H-3

Page 268

Applies to: LED Indication

Behavior

Base Station

Scanner

Battery charge complete

Green LED stays ON when charge is complete and scanner is seated in the Base Station.

YES

NO

Battery charge error

Yellow LED blinks 550mS on/ 1500mS off when there is a charge error and scanner is seated in the Base Station.

YES

NO

Error Codes Upon startup, if the scanner sounds a long tone, this means the scanner has not passed its automatic Selftest and has entered FRU1 isolation mode. If the scanner is reset, the sequence will be repeated. The following table describes the LED flashes/beep codes associated with an error found. NUMBER OF LED FLASHES/BEEPS

ERROR

1

Configuration

2

Interface PCB

4

Imager Module

5

Laser Pointer (if so equipped)

6

Digital PCB

14

CPLD/Code Mismatch

6a

Base Station

CORRECTIVE ACTION

Contact Helpdesk for assistance a. Base Station LED only - Repeats after 3 seconds 1. Field Replaceable Unit (FRU)

H-4

PowerScan® 7000BT SRI

Page 269

Error Codes

NOTES

Product Reference Guide

H-5

Page 270

NOTES

H-6

PowerScan® 7000BT SRI

Page 271

ASCII Chart ASCII Char.

Hex No.

ASCII Char.

Hex No.

ASCII Char.

Hex No.

ASCII Char.

Hex No.

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

SP ! “ # $ % & ’ ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F

@ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _

40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F

‘ a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL

60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F

Page 272

Australia

Japan

Datalogic Scanning Pty Ltd North Ryde, Australia Telephone: [61] (2) 9870 3200 Fax: [61] (2) 9878 8688

Datalogic Scanning KK Shinagawa, Tokyo, Japan Telephone: 81 (0)3 3491 6761 Fax: 81 (0)3 3491 6656

France and Benelux

Latin America

Datalogic Scanning Sarl LES ULIS Cedex, France Telephone: [33].01.64.86.71.00 Fax: [33].01.64 46.72.44

Datalogic Scanning, Inc Miami, Florida, USA Telephone: (305) 591-3222 Fax: (305) 591-3007

Germany

Spain and Portugal

Datalogic Scanning GmbH Darmstadt, Germany Telephone: 49 (0) 61 51/93 58-0 Fax: 49 (0) 61 51/93 58 58

Datalogic Scanning Sarl Sucursal en España Madrid, Spain Telephone: 34 91 746 28 60 Fax: 34 91 742 35 33

Italy

United Kingdom

Datalogic Scanning SpA Vimercate (MI), Italy Telephone: [39] (0) 39/62903.1 Fax: [39] (0) 39/6859496

Datalogic Scanning LTD Watford, England Telephone: 44 (0) 1923 809500 Fax: 44 (0) 1923 809 505 www.scanning.datalogic.com

Datalogic Scanning, Inc. 959 Terry Street Eugene, OR 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140

©2006-2007 Datalogic Scanning, Inc.

R44-2710 (Rev. A)

4/07