The text of a manual · part 8 of 20
Magellan 1400i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide: Data Editing
Pages 63 to 74 of 184, from Magellan 1400i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic 1400i
Page 63
Chapter 4
Data Editing Data Editing Overview It is not recommended to use these features with IBM or Wand Emulation interfaces. CAUTION
When a barcode is scanned, additional information can be sent to the host computer along with the barcode data. This combination of barcode data and supplementary user-defined data is called a “message string.” The features in this chapter can be used to build specific user-defined data into a message string. There are several types of selectable data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. Figure 4-1 shows the available elements you can add to a message string: Figure 4-1. Breakdown of a Message String Label ID Transmission: Enable this option to transmit the Label ID you configure for the scanned symbology.
OR... Prefix
Label ID
AIM ID
Bar Code Data
Label ID
Suffix
AIM ID: This function is used to identify and display the common label identifier for its symbology. When enabled, this ID code will be transmitted before the scanned bar code data. 00 - 20 Characters (ASCII)
Please Keep In Mind... •
Modifying a message string is not a mandatory requirement. Data editing is sophisticated feature allowing highly customizable output for advanced users. Factory default settings for data editing is typically set to NONE.
•
A prefix or suffix may be applied (reference the Symbologies chapter for these settings) across all symbologies (set via the Global features in this chapter).
•
You can add any character from the ASCII Chart (from 00-7F) on the inside back cover of this manual as a prefix, suffix or Label ID.
Product Reference Guide
4-1
Page 64
Data Editing
•
Enter prefixes and suffixes in the order in which you want them to appear on the output.
Global Prefix/Suffix Up to 20 ASCII characters may be added as a prefix (in a position before the barcode data) and/ or as a suffix (in a position following the barcode data) as indicated in Figure 4-2. Figure 4-2. Prefix and Suffix Positions
OR... Prefix
Label ID
AIM ID
Bar Code Data
Label ID
Suffix
00 - 20 Characters (ASCII)
AND OR Example: Setting a Prefix
In this example, we’ll set a prefix for all symbologies. 1. Determine which ASCII character(s) are to be added to scanned barcode data. In this example, we’ll add a dollar sign (‘$’) as a prefix. 2. Scan the START barcode. 3. Scan the SET PREFIX barcode. 4. Reference the ASCII Chart on the inside back cover of this manual, to find the hex value assigned to the desired character. The corresponding hex number for the ‘$’ character is 24. To enter this selection code, scan the ‘2’ and ‘4’ barcodes from Appendix C, AlphaNumeric Pad. 5. Scan the END barcode to exit Programming Mode. If less than the expected string of 20 characters are selected, scan the END barcode twice to accept the selections and exit Programming Mode. NOTE
6. The resulting message string would appear as follows: Scanned barcode data:12345 Resulting message string output: $12345
4-2
Magellan® 1400i
Page 65
Global Prefix/Suffix
Global Prefix/Suffix, cont. START / END PROGRAMMING BARCODES Sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to 7F. To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set Prefix” or “Set Suffix,” followed by the digits from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired character(s). Reference the section, "Example: Setting a Prefix", for more information. Exit programming mode by scanning the “START/END” barcode again (scan “START/END” twice if less than 20 characters have been selected). DEFAULT SETTING PREFIX: 00 (None) DEFAULT SETTING SUFFIX: 0D (CR)
Set Prefix
Set Suffix
Product Reference Guide
4-3
Page 66
Data Editing
AIM ID AIM (Automatic Identification Manufacturers) label identifiers are assigned from a globally standardized list, as opposed to custom label ID characters you select yourself, and can be included with scanned barcode data. AIM label identifiers consist of three characters as follows: •
A close brace character (ASCII ‘]’), followed by...
•
A code character (see the table below), followed by...
•
A modifier character (the modifier character is symbol dependent) SYMBOLOGY
CHAR
SYMBOLOGY
CHAR
UPC/EAN
E
Code 128/EAN 128
C
Code 39
A
MSI/Plessey
M
Codabar
F
GS1 DataBarGS1 DataBar (GS1 DataBar Omnidirectional, GS1 DataBar Expanded, GS1 DataBar Limited)
e
Interleaved 2 of 5
I
Standard 2 of 5
S
Code 93
G
ISBN
Xa a. ISBN (X with a 0 modifier character)
Figure 4-3. AIM ID
Prefix
Label ID
AIM ID
Bar Code Data
Label ID
Suffix
START / END PROGRAMMING BARCODES Disable AIM ID DEFAULT
Enable AIM ID
4-4
Magellan® 1400i
Page 67
Label ID
Label ID A Label ID is a customizable code of up to two ASCII characters (00-7F hex), used to identify a barcode (symbology) type. See Appendix D, Default Settings, for a listing for common symbologies. It can be appended previous to or following the transmitted barcode data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs individually per symbology. If you wish to program the scanner to always include an industry standard label identifier for ALL symbology types, see the previous feature, AIM ID. To configure a Label ID: 1. Scan the START barcode. 2. Select Label ID position as either BEFORE or AFTER by scanning the appropriate barcode. 3. Scan a barcode to select the symbology for which you wish to configure a custom Label ID. 4. Determine the desired character(s) (you may choose either one or two) which will represent the Label ID for the selected symbology. Next, turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID. For example, if you wish to select an equal sign (=) as a Label ID, the chart indicates its associated hex characters as 3D. 5. Turn to Appendix C, Alpha-Numeric Pad and scan the barcodes representing the hex characters determined in the previous step. For the example given, the characters ‘3’ and ‘D’ would be scanned. 6. Scan the END barcode to exit programming mode. Figure 4-4. Label ID Position Options
Prefix
Label ID
Aim ID
Bar Code Data
Label ID
Suffix
OR
Product Reference Guide
4-5
Page 68
Data Editing
Label ID, cont. START / END PROGRAMMING BARCODES
Label ID Transmission: Disable
Label ID Position: Before Bar Code Data DEFAULT
Label ID Position: After Bar Code Data
Set UPC-A Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-A w/P2 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-A w/P5 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-A w/C128 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-E Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
4-6
Magellan® 1400i
Page 69
Label ID
Label ID, cont. START / END PROGRAMMING BARCODES
Set UPC-E w/P2 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: E (45 hex) Set UPC-E w/P5 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Set UPC-E w/C128 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Set EAN-8 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-8 w/P2 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-8 w/P5 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-8 w/C128 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-13 Label ID Character(s) ³ 0FOR 0 THIS 2 FEATURE: 7 DEFAULT SETTING F (46 hex)
Product Reference Guide
4-7
Page 70
Data Editing
Label ID, cont. START / END PROGRAMMING BARCODES
Set EAN-13 w/P2 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Set EAN-13 w/P5 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Set EAN-13 w/C128 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Set ISBN Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: I (49 hex)
Set IATA Label ID Character(s) ³ FOR 0 3THIS 4 FEATURE: C DEFAULT SETTING IA (4941 hex)
Set GTIN Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: G (47 hex)
Set GTIN w/P2 addon Label ID Character(s) ³ FOR 0 THIS6FEATURE: 1 DEFAULT SETTING G2 (4732 hex)
Set GTIN w/P5 addon Label ID Character(s) ³ FOR 0 5THIS6 FEATURE: 2 DEFAULT SETTING G5 (4735 hex)
4-8
Magellan® 1400i
Page 71
Label ID
Label ID, cont. START / END PROGRAMMING BARCODES
Set GTIN w/C128 addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: G8 (4738 hex)
Set GS1 DataBar Ominidirectional Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: R4 (5234 hex)
Set GS1 DataBar Expanded Label ID Character(s) ³ FOR 0 THIS 4 DFEATURE: B DEFAULT SETTING RX (5258 hex)
Set GS1 DataBar Limited Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: RL (524C hex) Set Code 39 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: * (2A hex) Set Pharmacode 39 Label ID Character(s) ³ DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set Code 128 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: # (23 hex)
Set I 2 of 5 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: i (69 hex)
Product Reference Guide
4-9
Page 72
Data Editing
Label ID, cont. START / END PROGRAMMING BARCODES
Set Codabar Label ID Character(s) ³ 0FOR0 THIS 3 FEATURE: 7 DEFAULT SETTING % (25 hex)
Set Code 93 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: & (26 hex)
Set Code 11 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: @ (40 hex)
Set MSI/Plessey Label ID Character(s) ³ DEFAULT SETTING FOR THIS FEATURE: @ (40 hex)
Set Std 2 of 5 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: s (73 hex)
Set PDF417 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: P (5000 hex)
Set Micro PDF417 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: mP (6D50 hex)
Set PDF 417 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: P (0x5000)a
Set Datamatrix Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: Dm (0x446D) a. Default setting exceptions for PDF 417 Label ID are as follows: Default for RS-232 WN is ‘Q’ (0x5100). Default for USB-HIDPOS is ‘P ‘ (0x5020), or ‘P-Space’.
4-10
Magellan® 1400i
Page 73
Case Conversion
Case Conversion This feature can convert scanned barcode data to either all lower case (a through z) or all upper case (A through Z) characters. Case conversion affects ONLY scanned barcode data, and does not affect Label ID, Prefix, Suffix, or other appended data. NOTE
START / END PROGRAMMING BARCODES Disable DEFAULT ³
Convert to Upper Case
Convert to Lower Case
Product Reference Guide
4-11
Page 74
Data Editing
Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done. For example, if you have the character conversion configuration item set to the following: 41423132FFFFFFFF The first pair is 4142 or AB (41 hex is an ASCII capital A, 42 hex is an ASCII capital B) and the second pair is 3132 or 12 (31 hex is an ASCII 1, 32 is an ASCII 2). The other two pairs are FFFF and FFFF. With the label, AG15TA81, it would look as follows after the character conversion: BG25TB82. The A characters were converted to the B character and the 1 characters were converted to the numeral 2 character. Nothing is done with the last two character pairs, since they are all FF. To set Character Conversion: 1. Scan the START/END barcode. 2. Scan the Character Conversion barcode. 3. Determine the desired string. Up to sixteen positions can be determined as in the above example. Next, turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits needed to fulfill the string. 4. Turn to Appendix C, Alpha-Numeric Pad and scan the barcodes representing the hex characters determined in the previous step. 5. Scan the START/END barcode to exit Programming Mode. If less than the expected string of 16 characters are selected, scan the START/END barcode twice to accept the selections and exit Programming Mode. NOTE
START / END PROGRAMMING BARCODES
Character Conversion DEFAULT SETTING FOR THIS FEATURE: FFFFFFFFFFFFFFFF hex (no conversion)
4-12
Magellan® 1400i