Page 45

Interface Features

RS-232 Interface Features, cont. ACK NAK Options This enables/disables the ability of the scanner to support the RS-232 ACK/NAK protocol. When configured, the scanner and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Selections for this option are: •

Disable

•

Enable for label transmission, the scanner expects an ACK/NAK response from the host when a label is sent

•

Enable for host-command acknowledge, the scanner will respond with ACK/NAK when the host sends a command

•

Enable for label transmission and host-command acknowledge

START / END PROGRAMMING BAR CODES Disable ACK NAK DEFAULT

Enable ACK NAK for Transmission

Enable ACK NAK for host command acknowledge

Enable ACK NAK for transmission and host command

Product Reference Guide

3-19

Page 46

Interface Related Features

RS-232 Interface Features, cont. ACK Character

START / END PROGRAMMING BAR CODES Sets the ACK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as in “005”. To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set ACK Character,” followed by the digits from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired character. Exit programming mode by again scanning the “START/END” barcode above. DEFAULT SETTING FOR THIS FEATURE: 006 (ACK)

Set ACK Character

NAK Character

START / END PROGRAMMING BAR CODES Sets the NAK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as in “005”. To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set NAK Character,” followed by the digits from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired character. Exit programming mode by again scanning the “START/END” barcode above. DEFAULT SETTING FOR THIS FEATURE: 021 (!) Set NAK Character

3-20

Magellan® 1400i

Page 47

Interface Features

RS-232 Interface Features, cont. Retry on ACK NAK Timeout Enables/disables retry after the configurable ACK NAK Timeout Value (set in the following feature) has expired.

START / END PROGRAMMING BAR CODES

Disable Retry on ACK NAK Timeout

Enable Retry on ACK NAK Timeout DEFAULT

ACK NAK Timeout Value

START / END PROGRAMMING BAR CODES This item specifies the time the scanner will wait for an ACK character from the host following a label transmission. 000 = Infinite timeout 001 - 075 = Timeout in 200-millisecond increments To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set ACK NAK Timeout Value,” followed by the two digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired value. Exit programming mode by again scanning the “START/END” barcode above. DEFAULT SETTING FOR THIS FEATURE: 001 (200 msec) Set ACK NAK Timeout Value

Product Reference Guide

3-21

Page 48

Interface Related Features

RS-232 Interface Features, cont. ACK NAK Retry Count START / END PROGRAMMING BAR CODES This feature sets the number of times for the scanner to retry a label transmission under a retry condition. 000 = No retry 001 - 254 = Retry for the specified number of times 255 = Retry forever To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set ACK NAK Retry Count,” followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired retry count. Exit programming mode by again scanning the “START/END” barcode above DEFAULT SETTING FOR THIS FEATURE: 003

Set ACK NAK Timeout Value

3-22

Magellan® 1400i

Page 49

Interface Features

RS-232 Interface Features, cont. ACK NAK Error Handling This item specifies the method the scanner will use to handle errors detected while waiting to receive the ACK character from the host. Errors include unrecognized host commands and communication errors such as parity or framing errors. Choices are: 00 = Ignore errors detected (recommended setting) 01 = Process error as valid ACK character (risk of lost label data) 02 = Process error as valid NAK character (risk of duplicate label data) START / END PROGRAMMING BAR CODES Ignore Errors Detected DEFAULT

Process error as valid ACK character

Process error as valid NAK character

Product Reference Guide

3-23

Page 50

Interface Related Features

RS-232 Interface Features, cont. Transmission Failure Indication Enables/disables bad-label indication upon transmission failure.

START / END PROGRAMMING BAR CODES

Disable Transmission Error Indication

Enable Transmission Error Indication DEFAULT

USB-OEM Interface Features USB-OEM Device usage The USB-OEM protocol allows for the scanner to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have connected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate. Options are: •

Table Top Scanner

•

Handheld Scanner START / END PROGRAMMING BAR CODES Configure as Table Top Scanner DEFAULT

Configure as Handheld Scanner

3-24

Magellan® 1400i

Page 51

Interface Features

IBM IBM Transmit Labels in Code 39 Format This feature enables/disables scanner's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Codabar and Code 93 for USB-OEM; Code 128, Codabar and Code 93 for IBM Port 5B; and Codabar and Code 93 for IBM Port 9B.

START / END PROGRAMMING BAR CODES Disable Convert to Code 39 DEFAULT

Enable Convert to Code 39

Product Reference Guide

3-25

Page 52

Interface Related Features

Wand Emulation Supported Symbologies The Wand Emulation interface will transmit barcode data as a wand device would. This interface will transmit the following barcode symbologies: •

UPC/EAN

•

UPC/EAN with addons

•

Code 39

•

Full ASCII Code 39

•

Interleaved 2 of 5

•

Codabar

•

Code 128

Pharmacode 39 is transmitted as Code 39. All other barcode symbology types read by the scanner will be transmitted as Code 128.

Wand Emulation Bar Code Format The following format settings are required for the wand emulation interface. These settings have been pre-configured at the factory for Wand Emulation scanners.

3-26

•

UPC-A barcodes must include all 12 digits.

•

UPC-E barcodes must contain 8 digits, including a system digit, 6 data digits, and the check digit.

•

EAN-13 barcodes must have all 13 digits.

•

EAN-8 barcodes must include all 8 digits.

•

Code 39, Code 39 Full ASCII, and Pharmacode 39 barcodes must NOT contain start / stop characters.

•

Codabar barcodes must include the start / stop characters, presented in the ABCD format.

•

Interleaved 2 of 5 barcodes must have an even number of digits.

Magellan® 1400i

Page 53

Interface Features

Wand Emulation, cont. Bar/Space Polarity Low/High, Black will be transmitted as a low voltage level (0 to +0.7V) and space as high level (+2.4 to +5.25V). High/Low, Black will be transmitted as a high voltage level (+2.4 to +5.25V) and space as low level (0 to +0.7V).

START / END PROGRAMMING BAR CODES Bar/Space = Low/High

Bar/Space = High/Low DEFAULT

Wand Idle State This feature specifies the level of the wand output signal when idle. TTL logic levels: High voltage level (+2.4 to +5.25V) Low voltage level (0 to +0.7V).

START / END PROGRAMMING BAR CODES Wand Idle State = Low DEFAULT

Wand Idle State = High

Product Reference Guide