The text of a manual · part 3 of 20
Magellan 1400i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide: General Features
Pages 13 to 26 of 184, from Magellan 1400i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic 1400i
Page 13
Chapter 2
General Features 1D Double Read Timeout The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again (e.g. two identical items in succession).
START / END PROGRAMMING BAR CODES
0.1 Second
0.2 Second
0.3 Second
0.4 Second
0.5 Second
0.6 Second DEFAULT
Product Reference Guide
2-1
Page 14
General Features
1D Double Read Timeout, cont. START / END PROGRAMMING BAR CODES
0.7 Second
0.8 Second
0.9 Second
1 Second
1D Label Gone Timeout This feature sets the time after the last label segment is seen before the scanner prepares for a new label.
START / END PROGRAMMING BAR CODES Sets the label gone timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set Label Gone Timeout,” followed by three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing the desired time value. Exit programming mode by scanning the “START/END” bar code again. DEFAULT SETTING FOR THIS FEATURE: 200 milliseconds (020)
Set Label Gone Timeout
2-2
Magellan® 1400i
Page 15
Sleep Mode
Sleep Mode This feature specifies the amount of time with no bar code reads before the scanner enters sleep mode.
START / END PROGRAMMING BAR CODES 15 Seconds DEFAULT
30 Seconds
1 Minute
2 Minutes
3 Minutes
4 Minutes
5 Minutes
Product Reference Guide
2-3
Page 16
General Features
Sleep Mode, cont. START / END
PROGRAMMING BAR CODES 6 Minutes
7 Minutes
8 Minutes
9 Minutes
10 Minutes DEFAULT
12 Minutes
15 Minutes
30 Minutes
1 Hour
2-4
Magellan® 1400i
Page 17
LED and Beeper Indicators
LED and Beeper Indicators Power On Alert Disables or enables the indication (a single beep) that the scanner has finished all its power up tests and is now ready for operation.
START / END PROGRAMMING BAR CODES
Disable
Enable DEFAULT
Product Reference Guide
2-5
Page 18
General Features
Good Read: When to Indicate This feature specifies when the scanner will provide indication (beep and/or flash its green LED) upon successfully reading a bar code. Choices are: •
Good Read = Indicate after decode
•
Good Read = Indicate after transmit
•
Good Read = Indicate after CTS goes inactive, then active This option (Indicate after CTS goes inactive, then active), which uses CTS, is only valid for RS-232 interfaces. NOTE
START / END PROGRAMMING BAR CODES After Decode DEFAULT
After Transmit ³
After CTS goes inactive, then active
2-6
Magellan® 1400i
Page 19
LED and Beeper Indicators
Good Read Beep Control This feature enables/disables the scanner’s ability to beep upon a successful decode of a bar code. START / END PROGRAMMING BAR CODES Disable
Enable DEFAULT
Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.) START / END PROGRAMMING BAR CODES Low
Medium DEFAULT
High ³
Product Reference Guide
0 0 1 4 0 2
2-7
Page 20
General Features
Good Read Beep Length Specifies the duration of a good read beep. START / END PROGRAMMING BAR CODES 60msec DEFAULT
80msec
100msec
120msec
140msec
160msec
180msec
200msec
2-8
Magellan® 1400i
Page 21
Productivity Index Reporting (PIR)
Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels. START / END PROGRAMMING BAR CODES
Low
Medium
High DEFAULT
Productivity Index Reporting (PIR) When PIR is enabled, label quality data is appended to decoded data before being presented to the POS. The PIR feature allows the scanner to provide information to an external computer, indicating how easy the label was to read.
NOTE
This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced capability.
START / END PROGRAMMING BARCODES Disable DEFAULT
Enable
Product Reference Guide
2-9
Page 22
General Features
Scanning Features Aiming Pointer This feature enables/disables the Aiming Pointer for all symbologies. START / END PROGRAMMING BAR CODES Disable DEFAULT
Enable always on
Targeted Scanning Mode Upon pressing the button, the scanner will project an aiming pattern to assist in centering over the bar code. Scanning then takes place as soon as the button is released. When add-ons are enabled and a bar code is being read while in Targeted Mode, position the pointer at or near the end of the base label to ensure the scanner will read both the base and add-on label. NOTE
Targeted Scanning Mode will read bar codes in any orientation. The scanner will return to full pattern Omni-directional Mode after either of the following has ocurred: - Good Read + Target Mode: Linger Time has elapsed. - Target Mode: Active Time + Target Mode: Linger Time has elapsed.
Configuration options for Targeted Scanning Mode are:
2-10
•
Target Mode: Active Time
•
Target Mode: Linger Time
Magellan® 1400i
Page 23
Scanning Features
Target Mode: Active Time Specifies the time duration the scanner attempts to decode labels while in the targeted mode of operation. START / END PROGRAMMING BAR CODES Extra Short Duration
Short Duration
Medium Duration DEFAULT
Long Duration
Product Reference Guide
2-11
Page 24
General Features
Target Mode: Linger Time Specifies the time duration the scanner remains in the targeted mode of operation after reading a bar code or after Target Mode: Active Time has expired, before reverting to Omni-directional Mode. The linger timer starts upon a good read or upon timeout of Target Mode: Active Time; whichever is earliest. A button press at any time will reset the process back to the start. Active Time and Linger Time settings are totally independent from one another.
NOTE
During the period Linger Time is active, no bar codes can be read, no matter what mode the scanner is in.
START / END PROGRAMMING BAR CODES Short Duration
Medium Duration DEFAULT
Long Duration
2-12
Magellan® 1400i
Page 25
Scanning Features
Wake Up Intensity This feature indicates the percentage of ambient light change which will trigger the scanner to wake up from Sleep Mode. Lower settings provide greater sensitivity.
START / END PROGRAMMING BAR CODES
5%
8%
10% DEFAULT
15%
20%
25% ³
0
3
B
8
1
9
30%
35%
Product Reference Guide
2-13
Page 26
General Features
Wake Up Intensity, cont. START / END PROGRAMMING BAR CODES 40%
50%
60%
70%
80%
2-14
Magellan® 1400i