Page 15

Chapter 2

General Features Double Read Timeout for Linear Labels This Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same linear label again (e.g. two identical items in succession).

START / END PROGRAMMING BARCODES 0.1 Second

0.2 Second

0.3 Second

0.4 Second DEFAULT

0.5 Second

0.6 Second

Product Reference Guide

7

Page 16

General Features

Double Read Timeout for Linear Labels, cont. START / END PROGRAMMING BARCODES

0.7 Second

0.8 Second

0.9 Second

1 Second

8

MagellanTM 1100i

Page 17

Double Read Timeout for 2D Labels

Double Read Timeout for 2D Labels This Double Read Timeout feature specifies the minimum allowable time between consecutive good reads of the same PDF 417, Micro PDF 417 Data Matrix, QR Code, Maxicode, Aztec or Composite label.

START / END PROGRAMMING BARCODES 1.5 Seconds

1.65 Seconds

1.8 Seconds DEFAULT

1.95 Seconds

2 Seconds

2.55 Seconds

Product Reference Guide

9

Page 18

General Features

Label Gone Timeout This feature sets the time after the last label segment is seen before the scanner prepares for a new label.

START / END PROGRAMMING BARCODES Sets the label gone timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set Linear Label Gone Timeout,” followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing the desired time value. Exit programming mode by scanning the “START/END” barcode again. DEFAULT SETTING FOR THIS FEATURE: 320 milliseconds (032)

Set Linear Label Gone Timeout

Productivity Index Reporting (PIR) When PIR is enabled, label quality data is appended to decoded data before being presented to the POS. The PIR feature allows the scanner to provide information to an external computer, indicating how easy the label was to read.

NOTE

This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced capability.

START / END PROGRAMMING BARCODES Disable DEFAULT

Enable

10

MagellanTM 1100i

Page 19

Sleep Mode

Sleep Mode This feature specifies the amount of time with no barcode reads before the scanner enters sleep mode.

START / END PROGRAMMING BARCODES Disable Sleep Mode

15 Seconds

30 Seconds

1 Minute

2 Minutes

3 Minutes

4 Minutes

5 Minutes

Product Reference Guide

11

Page 20

General Features

Sleep Mode, cont. START / END

PROGRAMMING BARCODES 6 Minutes

7 Minutes

8 Minutes

9 Minutes

10 Minutes DEFAULT

12 Minutes

15 Minutes

30 Minutes

1 Hour

12

MagellanTM 1100i

Page 21

LED and Beeper Indicators

LED and Beeper Indicators Power On Alert Disables or enables the indication (a single beep) that the scanner has finished all its power up tests and is now ready for operation. START / END PROGRAMMING BARCODES

Disable

Enable DEFAULT

ERI Active State High This setting specifies the active-state polarity of the External Read Indicator signal to High; the inactive state is the opposite polarity.

NOTE

Contact Technical Support for assistance in changing the ERI Active State to Low if needed. Configuration of this feature is available only through use of a special cable.

START / END PROGRAMMING BARCODES

ERI Active State = High

Product Reference Guide

13

Page 22

General Features

ERI Timeout Specifies the amount of time the External Read Indicator (ERI) signal is held active for a good read. START / END PROGRAMMING BARCODES Sets the ERI timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set ERI Timeout,” followed by the two digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing the desired time value. Exit programming mode by scanning the “START/END” barcode again. DEFAULT SETTING FOR THIS FEATURE: 20 milliseconds (02)

Set ERI Timeout

14

MagellanTM 1100i