For the Datalogic 1100i

Page 165

2D Symbologies

Datamatrix, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the Datamatrix Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the minimum length by following the Datamatrix Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the maximum length by following the Datamatrix Length 1, Length 2 Programming Instructions below.

START / END PROGRAMMING BARCODES Variable Length Decoding DEFAULT

Fixed Length Decoding

Product Reference Guide

157

Page 166

2D Symbologies

Datamatrix, continued Datamatrix Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Alpha-Numeric Pad and scan the four digits (zero-padded) representing the length. For Datamatrix barcodes, only the data characters are included in the length calculations. NOTE

Any value set higher than 800 will be considered to be 800.

Scan the END barcode.

START / END PROGRAMMING BARCODES

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 0001

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 0800

158

MagellanTM 1100i

Page 167

2D Symbologies

QR Code Disable/Enable QR Code When disabled, the scanner will not read QR Code labels. START / END PROGRAMMING BARCODES Disable QR Code DEFAULT

Enable QR Code

Product Reference Guide

159

Page 168

2D Symbologies

QR Code, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the QR Code Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the minimum length by following the QR Code Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the maximum length by following the QR Code Length 1, Length 2 Programming Instructions below.

START / END PROGRAMMING BARCODES Variable Length Decoding DEFAULT

Fixed Length Decoding

160

MagellanTM 1100i

Page 169

2D Symbologies

QR Code, continued QR Code Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Alpha-Numeric Pad and scan the four digits (zero-padded) representing the length. For QR Code labels, only the data characters are included in the length calculations.

NOTE

Any value set higher than 2710 will be considered to be 2710.

Scan the END barcode.

START / END PROGRAMMING BARCODES

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 0001

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 2710

Product Reference Guide

161

Page 170

2D Symbologies

Maxicode Disable/Enable Maxicode When disabled, the scanner will not read Maxicode labels. START / END PROGRAMMING BARCODES Disable Maxicode DEFAULT

Enable Maxicode

162

MagellanTM 1100i

Page 171

2D Symbologies

Maxicode, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the Maxicode Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the minimum length by following the Maxicode Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the maximum length by following the Maxicode Length 1, Length 2 Programming Instructions below.

START / END PROGRAMMING BARCODES Variable Length Decoding DEFAULT

Fixed Length Decoding

Product Reference Guide

163

Page 172

2D Symbologies

Maxicode, continued Maxicode Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Alpha-Numeric Pad and scan the four digits (zero-padded) representing the length. For Maxicode labels, only the data characters are included in the length calculations. NOTE

Any value set higher than 138 will be considered to be 138.

Scan the END barcode.

START / END PROGRAMMING BARCODES

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 0001

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 0138

164

MagellanTM 1100i