Page 151

Standard 2 of 5

Standard 2 of 5, continued Check Digit Transmit When this option is enabled, the scanner will transmit the check digit. START / END PROGRAMMING BARCODES Disable Check Digit Transmission

Enable Check Digit Transmission DEFAULT

Product Reference Guide

143

Page 152

Symbologies

Standard 2 of 5, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first fixed length by following the Standard 2 of 5 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the Standard 2 of 5 Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START/END barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first variable length by following the Standard 2 of 5 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the Standard 2 of 5 Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BARCODES Variable Length Decoding DEFAULT

Fixed Length Decoding

144

MagellanTM 1100i

Page 153

Standard 2 of 5

Standard 2 of 5, continued Standard 2 of 5 Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the two digits (zero padded) representing the length in decimal notation. For Standard 2 of 5 barcodes, all check and data characters are included in the length calculations. NOTE

4. Scan the END barcode. START / END PROGRAMMING BARCODES Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 08 Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 50

Product Reference Guide

145

Page 154

Symbologies

Standard 2 of 5, continued Standard 2 of 5 Stitching Enables/disables stitching for Standard 2 of 5 barcodes. When parts of a Standard 2 of 5 label are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software, and the data will be decoded if all barcode proofing requirements are met. Only functions when Fixed Length Decoding is enabled. NOTE

START / END PROGRAMMING BARCODES Disable Std 2 of 5 Stitching DEFAULT

Enable Std 2 of 5 Stitching

146

MagellanTM 1100i

Page 155

Standard 2 of 5

Standard 2 of 5, continued Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read. START / END PROGRAMMING BARCODES Minimum = 1 Read DEFAULT

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

Product Reference Guide

147

Page 156

Symbologies

NOTES

148