Page 49

Chapter 2 - Installation, Configuration, Usage

Link for changing password

Figure 11: Configuration & Administration Menu page This page gives a brief description of all menu options. A menu of links is provided along the left side of the page. A summary of what each link leads to is shown on Table 3: Configuration Section through Table 6: Information Section.

Security Issue. Change the password of the Web root user as soon as possible. The user database for the Web Configuration Manager is different than the system user database, so the root password can be different. See Changing the Root Password in Appendix F - Web User Management.

Step 6: Click on the General link.

User Guide

49

Page 50

Chapter 2 - Installation, Configuration, Usage

Figure 12: General page Step 7: Configure parameters presented in the fields. Step 8: Click on the Submit button. Make the changes effective. Click on the Administration > Run Configuration link, check the Serial Ports/ Ethernet/Static Routes box and click on the Activate Configuration button. If you disabled DHCP and changed your Ethernet IP, you will lose your connection. You will need to use your browser to connect to the new IP. Step 9: Click on the Save Configuration to Flash button. The configuration was saved in flash. The new configuration will be valid and running. The Cyclades-TS is now configured as a CAS with its assigned (by DHCP Server or you) IP address, with no authentication, and accepting telnet to the serial ports. You can telnet the CAS IP + serial port 1 with the following command: telnet <IP assigned> 7001

50

Cyclades-TS

Page 51

Chapter 2 - Installation, Configuration, Usage Note. Serial port 1 is configured as 9600, 8N1 by default. The server connected to this serial port has to have the same configuration for its serial port.

To explore the Cyclades-TS features, either continue configuration using your browser, use the vi editor from the console, or use CLI, if appropriate. A description of each of the links on the five sections of the Configuration and Administration menu page is provided on the following five tables:

Table 2: Applications Section Link Name

Description of Page Contents

Logout

Exits the Web Management Service

Connect to Serial Ports

Telnet/SSH connection to Portslave

User Guide

51

Page 52

Chapter 2 - Installation, Configuration, Usage Table 3: Configuration Section Link Name Configuration General

Description of Page Contents This section contains the configuration tools Unit Description, Ethernet, DNS, Name Service Access, Data Buffering

Syslog

Configuration for the syslog-ng

SNMP

Configuration for the SNMP server

Serial Ports

Configuration of Portslave package

Serial Port Groups

Configuration of User Groups for Serial Ports

Host Table

Table of hosts in /etc/hosts

Static Routes IP Chains

Static routes defined in /etc/network/st_routes Shows IP Chains entries

Boot Configuration

Configuration of parameters used in the boot process

Edit Text File

Tool to edit a configuration file

System Users

Management of system users defined in /etc/password

System Groups

Management of system groups defined in /etc/groups

52

Cyclades-TS

Page 53

Chapter 2 - Installation, Configuration, Usage Table 4: Administration Section Link Name Reboot

Description of Page Contents Resets the equipment

Download/ Upload Image

Uses an FTP server to load/save a kernel image

Load/Save Configuration

Uses flash memory or an FTP server to load or save the TS’ configuration

Run Configuration

Makes the configuration changes effective

Set Date/Time

Set the TS’ date and time

Active Sessions

Shows the active sessions

Process Status

Shows the running processes and allows the administrator to kill them

Restart Processes

Allows the administrator to start or stop some specific processes

PCMCIA

Allows the administrator to insert and eject PCMCIA cards

Table 5: Web User Management Section Link Name Users Groups

Description of Page Contents List of users allowed to access the Web server List of possible access groups

Access Limits

List of access limits for specific URLs

Load/Save Configuration

Load/Save Configuration in /etc/websum.conf

User Guide

53

Page 54

Chapter 2 - Installation, Configuration, Usage Table 6: Information Section Link Name Interface Statistics

Description of Page Contents Shows statistics for all active interfaces

DHCP client

Shows host information from DHCP

Serial Ports

Shows the status of all serial ports

Routing Table

Shows the routing table and allows the administrator to add or delete routes

ARP Cache

Shows the ARP cache

IP Statistics

Shows IP protocol statistics

ICMP Statistics

Shows ICMP protocol statistics

TCP Statistics

Shows TCP protocol statistics

UDP Statistics

Shows UDP protocol statistics

RAM Disk Usage

Shows the TS File System status

System Information

54

Shows information about the kernel, time, CPU, and memory

Cyclades-TS

Page 55

Chapter 2 - Installation, Configuration, Usage Configuration using Telnet The Cyclades-TS box comes with DHCP client enabled. If you have a DHCP Server installed on your LAN, you can skip Step 2 below. If not, the DHCP request will fail and an IP address pre-configured on the Console server’s Ethernet interface (192.168.160.10) will be used instead. To access the box using telnet: Step 1: Connect Hub to workstation and TS. Your workstation and your TS must be on the same physical LAN. Connect one RJ-45 cable from the Ethernet port of the TS to a spare port from a hub, and another cable from another spare port of that same hub to the workstation used to manage the servers. Step 2: If you do not have a DHCP Server in your LAN, add a route pointing to the TS IP. From the workstation issue a command to add a route pointing to the network IP address of the TS (192.168.160.0) accessed through the workstation’s Ethernet interface. For Linux, the command would be: route add -net 192.168.160.0/24 gw <IP address assigned to the workstation’s Ethernet interface> Example: if the workstation has IP address 200.246.93.150 the command would be: route add -net 192.168.160.0/24 gw 200.246.93.150

For Windows, the command would be: route add 192.168.160.0 mask 255.255.255.0 <IP address assigned to the workstation’s Ethernet interface> Example: if the workstation has IP address 200.246.93.150 the command would be: route add 192.168.160.0 mask 255.255.255.0 200.246.93.150 Step 3: Telnet to <IP assigned by DHCP Server or 192.168.160.10 if there is no DHCP Server>. Step 4: Enter root as login name and tslinux as password.

User Guide

55

Page 56

Chapter 2 - Installation, Configuration, Usage Step 5: Type wiz and press Enter. A Configuration Wizard screen will appear on your telnet screen, asking you a series of questions. *********************************************************** ********* C O N F I G U R A T I O N W I Z A R D ********* *********************************************************** INSTRUCTIONS for using the Wizard: You can: 1) Enter the appropriate information for your system and press ENTER. Enter '#' if you want to deactivate that parameter or 2) Press ENTER if you are satisfied with the value within the brackets [ ] and want to go on to the next parameter or 3) Press ESC if you want to exit. NOTE: For some parameters, if there is nothing within the brackets, it will continue to ask for a value. In that case, you must enter a valid value or # if you do not wish to configure the value.

Press ENTER to continue... After you input the requested parameters you will receive a confirmation screen: Current configuration: Hostname : CAS DHCP: disabled System IP : 192.168.160.10 Domain name : cyclades.com Primary DNS Server : 197.168.160.200 Gateway : eth0 Network Mask : 255.255.255.0 56

Cyclades-TS

Page 57

Chapter 2 - Installation, Configuration, Usage If the parameters are correct, “y” should be typed; otherwise, type “n” and then “c” when asked to change the parameters or quit the program. After the parameters are confirmed, the next question will be whether to save the configuration to flash. Select “y” to make the new configuration permanent in non-volatile memory. At this point you may lose your connection when saving the changes, if you disabled DHCP and assigned an IP address. Don’t worry! The new configuration will be valid. The Cyclades-TS is now configured as a CAS with its assigned (by DHCP or you) IP address, with no authentication, and accepting telnet to the serial ports. You can telnet the CAS IP + serial port 1 with the following command: telnet <IP assigned> 7001 Note. Serial port 1 is configured as 9600, 8N1 by default. The server connected to this serial port has to have the same configuration for its serial port.

After you confirm the basic parameters, you will be presented with the shell prompt. From there, either select to continue configuration using the vi editor or continue using a browser. For additional configuration, see Chapter 3 - Additional Features in this guide.

User Guide

57

Page 58

Chapter 2 - Installation, Configuration, Usage The Installation and Configuration Process Task 1: Connect the Cyclades-TS to the Network and other Devices Power Users Connect a PC or terminal to the Cyclades-TS using the console cable. If you are using a PC, HyperTerminal can be used in the Windows operating system and Kermit or Minicom in the UNIX operating system. When the Cyclades-TS boots properly, a login banner will appear. Log in as root (default password is tslinux). A new password should be created as soon as possible. The terminal parameters should be set as follows: •

Serial Speed: 9600 bps

•

Data Length: 8 bits

•

Parity: None

•

Stop Bits: 1 stop bit

•

Flow Control: none

•

ANSI emulation

You may now skip to Task 4: Edit the pslave.conf file.

Important! Any configuration change must be saved in flash once validated. To save in Flash run saveconf (see Task 7: Save the changes). To validate/activate a configuration, run signal_ras hup (see Task 5: Activate the changes).

Note: If your terminal does not have ANSI emulation, select vt100; then, on the TS, log in as root and switch to vt100 by typing: TERM=vt100;export TERM