Page 87

Chapter 3 - Additional Features all.users

Restricts access to ports by user name (only the users listed can access the port or, using the character “!,” all but the users listed can access the port.) A single comma and spaces/tabs may be used between names. A comma may not appear between the “!” and the first user name. The users may be local, Radius or TacacsPlus. User groups (defined with the parameter conf.group) can be used in combination with user names in the parameter list. Notice that these are common users, not administrators. Example: all.users ! joe, mark, user_group. In this example, the users joe, mark, and members of user_group cannot access the port.

all.poll_interval

Valid only for protocols socket_server and raw_data. When not set to zero, this parameter sets the wait for a TCP connection keep-alive timer. If no traffic passes through the Cyclades-TS for this period of time, the Cyclades-TS will send a line status message to the remote device to see if the connection is still up. If not configured, 1000 ms is assumed (the unit for this parameter is ms). If set to zero, line status messages will not be sent to the socket client.

all.tx_interval

Valid for protocols socket_server and raw_data. Defines the delay (in milliseconds) before transmission to the Ethernet of data received through a serial port. If not configured, 100ms is assumed. If set to zero or a value above 1000, no buffering will take place.

all.idletimeout

Valid only for the CAS configuration (protocols socket_server, socket_ssh, raw_data) and modbus. Specifies how long (in minutes) a connection can remain inactive before it is cut off. If set to zero (the default), the connection will not time out.

conf.group

Used to group users to simplify configuration of the parameter all.users later on. This parameter can be used to define more than one group. The format is: <group name>:<user1>{,<user2>[,<user3>]] Example: conf.group group_name: user1, user2.

s<n>.serverfarm

Alias name given to the server connected to the serial port. Server_connected. Example: s1.serverfarm Server_connected_serial1.

User Guide

87

Page 88

Access Method vi Method The parameters described above must be changed by directly editing the /etc/portslave/plsave.conf file.

Browser Method To configure Access Method with your browser: Step 1: Point your browser to the Console Server. In the address or location field of your browser type the Console Access Server’s IP address. For example: http://10.0.0.0 Step 2: Log in as root and type the Web root password configured by the Web server. This will take you to the Configuration and Administration page.

Serial Ports links

Link Panel

Figure 17: Configuration and Administration page Step 3: Select the Serial Ports link. Click on the Serial Ports link on the Link Panel to the left of the page or in the Configuration section of the page. This will take you to the Port Selection page.

88

Cyclades-TS

Page 89

Chapter 3 - Additional Features

Figure 18: Port Selection page Step 4: Select port(s). On the Port Selection page, choose all ports or an individual port from the dropdown menu. This will take you to the Serial Port Configuration page.

CAS profile button

Figure 19: Serial Port Configuration page

User Guide

89

Page 90

Access Method Step 5: Click the CAS profile button. Click the CAS profile button in the wizards section. The default CAS profile parameters are now loaded. Step 6: Scroll down to the Profile section. You can change the settings for all.ipno, all.socket_port, and all.protocol in this section.

Figure 20: Profile Section of Serial Port Configuration page Step 7: Scroll to the Authentication Section. You can configure the parameter all.users here under Access Restriction on Users. Step 8: Scroll to Console Access Server Section. You can configure the following parameters here: • all.sttyCmd • all.poll_interval • all.tx_interval • all.idletimeout Step 9: Configure s<n>.serverfarm. This parameter will not appear on the configuration page when “All ports” is selected. Scroll to the SSH section. Each port can be named after the server or device connected to it. This makes the process of associating what is connecting to which port easier. Step 10: Click the Submit button. This will take you back to the Port Selection page. At this point, the configuration file is written in the RAMdisk.

90

Cyclades-TS

Page 91

Chapter 3 - Additional Features Step 11: Click on the Serial Port Groups link on the Link Panel. Click the Add Group button that appears. A Serial Ports - Users Group Table Entry page appears.

Figure 21: Serial Ports - Users Group Table Entry page Step 12: Configure conf.group. Fill in the Group Name and Users fields to configure the group. Step 13: Click the Submit button. At this point, the configuration file is written in the RAMdisk. Step 14: Make the changes effective. Click on the Administration > Run Configuration link, check the Serial Ports/ Ethernet/Static Routes box and click on the Activate Configuration button. Step 15: Save it in the flash. Go to the link Administration > Load/Save Configuration and click the Save to Flash button.

Wizard Method Step 1: Bring up the wizard. At the command prompt, type the following to bring up the Access Method custom wizard: wiz --ac cas

User Guide

91

Page 92

Access Method This will bring up Screen 1: Screen 1: *********************************************************** ********* C O N F I G U R A T I O N W I Z A R D ********* *********************************************************** INSTRUCTIONS for using the Wizard: You can: 1) Enter the appropriate information for your system and press ENTER. Enter '#' if you want to deactivate that parameter or 2) Press ENTER if you are satisfied with the value within the brackets [ ] and want to go on to the next parameter or 3) Press ESC if you want to exit. NOTE: For some parameters, if there is nothing within the brackets, it will continue to ask for a value. In that case, you must enter a valid value or # if you do not wish to configure the value.

Press ENTER to continue... Screen 2: *********************************************************** ********* C O N F I G U R A T I O N W I Z A R D ********* *********************************************************** Current configuration: (The ones with the '#' means it's not activated.) all.ipno : # all.socket_port : 7001+ all.protocol : socket_server all.users : # all.poll_interval : # all.tx_interval : # 92

Cyclades-TS

Page 93

Chapter 3 - Additional Features all.idletimeout : # conf.group : #

Set to defaults? (y/n) [n] : Screen 3: *********************************************************** ********* C O N F I G U R A T I O N W I Z A R D ********* *********************************************************** ALL.IPNO - This is the default IP address of the system's serial ports. If configured as 192.168.1.101+, the '+' indicates that the first port should be addressed as 192.168.1.101 and the following ports should have consecutive values. Any host can access a port using its IP address as long as a path to the address exists in the host's routing table. all.ipno[#] :

ALL.SOCKET_PORT - This defines an alternative labeling system for the system ports. The '+' after the numerical value causes the interfaces (or ports) to be numbered consecutively. (e.g. interface 1 of your system is assigned port 7001, interface 2 has the value 7002, etc.) all.socket_port[7001+] :

User Guide

93

Page 94

Access Method Screen 4: *********************************************************** ********* C O N F I G U R A T I O N W I Z A R D ********* *********************************************************** ALL.PROTOCOL - The possible protocols are telnet, ssh1/ssh2, raw data, or modbus. (e.g. socket_server -telnet protocol, socket_ssh -ssh1/ssh2 protocol, raw_data -used to exchange data in transparent mode; similar to socket_server mode but without telnet negotiation breaks to serial ports modbus -an application layer messaging protocol for client/server communication widely used for industrial automation, etc.) all.protocol[socket_server] : ALL.MODBUS_SMODE - Communication mode through the serial ports. This parameter is valid only if the protocol configured is modbus. If it is and this parameter is not configured, ASCII mode will be assumed. (e.g. ascii -normal TX/RX mode, rtu -Remote Transmission mode where some time constraints are observed between characters while transmitting a frame) all.modbus_smode[#] : ALL.USERS - Restricts access to ports by user name. Only the users listed can access the port, or using a '!', all but the users listed can access the port. A single comma and spaces/tabs may be used between names. A comma may NOT appear between the '!' and the first user name. The users may be local, Radius or TacacsPlus. User groups (defined with the parameter conf.group) can be used in combination with user names in the parameter list. Notice that these are common users, not administrators. (e.g. !joe, mark, grp1 -the users, Joe, Mark, and members of grp1, cannot access the port.) all.users[#] :

94

Cyclades-TS

Page 95

Chapter 3 - Additional Features Screen 5: *********************************************************** ********* C O N F I G U R A T I O N W I Z A R D ********* *********************************************************** ALL.POLL_INTERVAL - Valid for protocols socket_server and raw_data. When not set to 0, this parameter sets the wait for a TCP connection keep-alive timer. If no traffic passes through the system for this period of time, the system will send a line status message to the remote device to see if the connection is still up. If not configured, default is 1000ms. If set to 0, line status messages will not be sent to the socket client. all.poll_interval[#] : ALL.TX_INTERVAL - Valid for protocols socket_server and raw_data. This parameter defines the delay (in milliseconds) before transmission to the Ethernet of data received through a serial port. If not configured, 100ms is assumed. If set to 0 or a value above 1000, no buffering will take place. all.tx_interval[#] :

Screen 6: *********************************************************** ********* C O N F I G U R A T I O N W I Z A R D ********* *********************************************************** ALL.IDLETIMEOUT - This parameter specifies how long (in minutes) a connection can remain inactive before it is cut off. If set to 0 (the default), the connection will not time out. all.idletimeout[#] :

User Guide

95

Page 96

Access Method CONF.GROUP - Used to combine users into a group. This simplifies the parameter, all.users. You can define more than one group. (e.g. groupName: user1, user2) conf.group[#] :sales: john, jane

Would you like to create another group? (y/n) [n] :

Screen 7: *********************************************************** ********* C O N F I G U R A T I O N W I Z A R D ********* ************************************************************ Current configuration: (The ones with the '#' means it's not activated.) all.ipno : # all.socket_port : 7001+ all.protocol : socket_server all.modbus_smode : # all.users : # all.poll_interval : # all.tx_interval : # all.idletimeout : # conf.group : # Are these configuration(s) all correct? (y/n) [n]: If you type 'n': Type 'c' to go back and CORRECT these parameters or 'q' to QUIT : Typing 'c' repeats the application, typing 'q' exits the entire wiz application. If you type 'y': Discard previous port-specific parameters? (y/n) [n] :

96

Cyclades-TS