Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 8

Apex II Portable Data Collection Terminal Operations & Programming Manual, Part 1: User's Manual, pages 55 to 63

Pages 55 to 63 of 71

The original document is the PDF (342 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Compsee Apex II

Page 55

COMPSEE Apex II HAND HELD COMPUTER Version 1.00 Data File Recovery Utility (C) 1995 Enter Comm Port (1 to 4): 1 Recover File ?ARRIER

Recover File Y/N

Y

FILES RECOVERED

Enter first letter of file name

EMPL AISLE BIN COND

Other programs will become available to you on the BBS as they are developed by Compsee. All of the programs discussed above have been included on the LinkMaster diskette. If you have installed this diskette, you will find all of them on your PC's hard disk in a directory called C:\Apexware.

BBS TROUBLESHOOTING PROCEDURES

Note You may have a potential problem if your modem is not Hayes compatible. PROBLEM

ACTION

Constant ringing.

The BBS is down or the wrong number was dialed.

Busy signal.

Someone else is using the BBS. Reduce the baud rate This will reduce the throughput, but will usually help if you have a noisy line. Or Ensure that the modem is plugged-in, powered-on, and securely connected to the PC. (The modem may be improperly set up)

Cannot connect to the BBS. Total disconnect while using the service.

Reduce the baud rate. This will reduce the throughput, but will usually help if you have a noisy line. Or If you have call waiting, another call has broken your BBS connection. Disable call waiting on your phone by pressing *,7,0 (push button) or by dialing 1170 (rotary phone). Re-connect to the BBS.

Unrecognizable characters are shown on the PC's screen.

Reduce the baud rate. This will reduce the throughput, but will usually help if you have a noisy line, Or Log-off and then log-on again.

Compsee, Inc. Apex-0698-Part 1: User’s Manual

55 Part 1

Page 56

7

ERROR CODES

Located within this quick reference appendix are the COMPSEE BASIC error codes that may appear on the data terminal during use. Also supplied are examples of some error conditions and the procedures for correcting them. Error codes are listed in numerical order, along with a description. In most cases, the corrective action is self-explanatory and is contained within the description of the error code.

Note The error codes listed below may be produced as a result of an error in your application program. In some cases, you will need to consult with the person who wrote your application program for assistance. Error messages appearing on the Apex II generally fall into one of two categories:

•

Errors where the user can recover without intervention from the applications programmer. This category of errors is grouped as follows:

n

•

The developer may have accounted for them in the program and programmed the application to automatically resume at another point.

Errors where the applications programmer must modify the program before you can continue working.

Because errors are dependent on the application program, every distinction cannot be made in this document. Attempt to recover from an error condition by using the procedures described in the examples that follow. If problems are still encountered, see your applications programmer. When the Apex II encounters an error not accounted for in the application, program execution may be halted (the information currently displayed is saved), and the error code and line number will be displayed on the first line of the Apex II's LCD. Example 1 If the Apex II were to attempt RS-232-C communications using RTS/CTS flow control with no device connected, the following error message would be shown on the Apex II's LCD: * E 24 L450 > where: E24 is the error code and L450 is the line number location of the error

NOTES 1) Errors of this type should be discussed with your programmer. DO NOT attempt to exit the DIAGNOSTIC mode without first consulting with your programmer. 2) Some application programs may be designed to delete data files and re-initiate variables to 0 values. By re-initializing your program with the <ALT> <R> key sequence, you could delete data. Consult with your programmer to determine if this is the case.

Compsee, Inc. Apex-0698-Part 1: User’s Manual

56 Part 1

Page 57

Example 2 If the error has not been accounted for in the program, you may encounter the situation where the message shown below will appear: ** BREAK ### ** where: ### is the line number where the abort took place If this is the case, you may be in the DIAGNOSTIC mode; not the IMMEDIATE mode. Press <ALT> <V> . If the operating system version number appears, you are in the IMMEDIATE mode. Or, you may see the following BREAK message with the > prompt: ** BREAK ### ** > Type QUIT and press <Enter>. You will then be placed in the IMMEDIATE mode. Detailed information on error codes can be found in the COMPSEE BASIC Interpreter Programmer's Manual.

Error Code 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

Compsee, Inc. Apex-0698-Part 1: User’s Manual

Description Line too long Out of table memory Invalid use of characters Name too long Invalid character Unmatched parentheses Invalid name Invalid number Missing Quote Invalid line number Out of program memory Undefined line number Invalid syntax Number out of range Cannot continue Duplicate Definition Array not dimensioned Invalid use of a variable Receive timeout Parity error Invalid record length on a load command Invalid record count on a load command Invalid header format on a load command Transmit timeout Invalid expression Divide by zero String too long Overflow

57 Part 1

Page 58

Error Code 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73

Compsee, Inc. Apex-0698-Part 1: User’s Manual

Description Underflow Reserved Invalid function parameters Cannot dimension a string to zero Numeric stack overflow Character stack or operator stack overflow Illegal expression Array out of bounds Invalid array reference Undefined label Duplicate label ELSE with no THEN IF with no THEN FOR with no NEXT WHILE with no WEND File does not exist File number incorrect File already open File record length invalid File with same name already exists File name invalid File not opened Out of file memory Too many files Form statement out of range Form statement syntax error More variables than form elements Read past the end of a record Write past the end of a record RESUME without error RETURN without GOSUB Cannot load the RAM file Reserved Illegal date or time Illegal cursor position Invalid input length Too much memory allocated by clear or invalid byte count Invalid RESTORE line RESTORE with no DATA statement NEXT with no FOR WEND with no WHILE Illegal mode Form field does not match data Out of data Out of buffer space

58 Part 1

Page 59

Error Code 74 75 76 77 78 79 80 81 82 83 84 85 86

Description Break point table full Read past end of file Write past end of file Reserved Reserved Reserved System Locked Invalid Lock/Unlock code System Cannot be unlocked Cannot edit program in FLASH Program too big to save to FLASH Program already in FLASH No program to save

The following are serious COMPSEE BASIC errors. If any of these errors are encountered, attempt to re-run the program. If that does not help, reboot the Apex II, reload the operating system and application program, and re-run the program.

Error Code

Description

200

Internal stack error

252

Cursor in illegal location

253

Internal load error

254

Scan loop error

255

Internal execution error

Note If the error message persists, it may be necessary to return the Apex II to Compsee for servicing. See Chapter 5 for the equipment return procedure.

8

KEYPAD COMMANDS

The key combinations shown in this appendix are those most commonly used. DIAGNOSTIC mode debug commands are also provided.

Compsee, Inc. Apex-0698-Part 1: User’s Manual

59 Part 1

Page 60

IMMEDIATE MODE COMMANDS The following key combinations are used while in the IMMEDIATE mode.

Function

Keypad

Reboot Apex II (Program remains in FLASH)

Hold down <ALT> and <.>, then press <PWR>

Reboot Apex II (Program is erased from FLASH)

Hold down <ALT> and <SPC>, then press <PWR>

Check version

<ALT> <V>

Display communication parameters

<ALT> <X>

Set communication parameters when they are displayed

<X> to change first number <Y> to change second number

Press <ENTER> to exit Clear buffers

<ALT> <Z>

Run the program

<ALT> <R>

Stop a running program (puts terminal in debug mode)

<ALT> <C>, then <ALT> <D>

Contrast level up

<ALT> <I>

Contrast level down

<ALT> <J>

Save program to FLASH

<ALT> <S>

To set input port on standard unit to wand or laser input

<ALT> <W>

Note See Part 3 of this manual, BASIC Interpreter Programmer's Manual, for detailed information on the IMMEDIATE mode commands.

DIAGNOSTIC MODE COMMANDS The following commands can be used to debug a program while in the DIAGNOSTIC mode. With the exception of the QUIT command, these commands will always be used exclusively by an applications programmer.

Note You must press <ENTER> after each command is typed.

Command

Description

G [line number]

Goto line number xx and continue running program (if line number is omitted, will start at the next line).

I [variable]

Used to input a value to the user-named variable. It's purpose is to troubleshoot a value of a variable during parts of a program.

B [line number]

Break - stop execution of a running program on line xx.

Compsee, Inc. Apex-0698-Part 1: User’s Manual

60 Part 1

Page 61

T

Trace on/off - allows programmer to trace line numbers as they are executed in a program.

P

Print a value.

QUIT

Quit out of DIAGNOSTIC mode into IMMEDIATE mode.

S

Single step through a program. Executes next program line and returns to DIAGNOSTIC mode.

Note See Part 3 of this manual, BASIC Interpreter Programmer's Manual, for detailed information on the DIAGNOSTIC mode commands.

9

MODEL DIFFERENCES AND TERMINAL SPECIFICATIONS

This section explains the specific differences among the various models of the Apex II Terminals.

MODEL DESIGNATIONS Model designations for the Apex II data collection terminals are defined as follows:

Modeld

Optional Accessories The optional accessories listed below are available for your Apex II data collection terminal:

•

RS-232-C interface Cable to DB 9-pin connector (1 included with the Apex II)

•

RS-232-C interface Cable to DB 25-pin connector

•

RS-232-C interface Cable to QuickReader Keyboard Wedge

•

RS-232-C interface Cable to QuickLink Keyboard Wedge

•

Nickel Metal Hydride (NIMH) Battery pack

•

Battery Charger (NIMH - Wall Charger to Apex II) For Internal Charging of Battery

Compsee, Inc. Apex-0698-Part 1: User’s Manual

61 Part 1

Page 62

•

Adapter Cable for External Charging of the NIMH Battery Pack Requires Battery Charger

•

Apex II Manual (1 included with the Apex II)

See Section 12 for a complete list of all Apex II part numbers.

APEX II SCANNING VARIABLES

Apex II with Detached Bar Code Scanner •

Depression of <SCAN> powers the terminal and the scanner. When the unit is powered, the red light can be seen on the reader. If desired, the application program can be modified through the SYSPARMS statement to leave the wand turned on. Refer to the COMPSEE BASIC Interpreter Programmer's Manual for details.

•

The port for connecting the scanning unit is a DB 9 male connector (see Section 10 for pin assignments).

•

A 6' (1.8 meter) coiled cable is normally attached to the reader.

Apex II with Integrated Laser Reader - Standard •

Reads bar codes using a non-contact, moving beam, 680 NM visible laser diode scanner.

•

A laser diode emitting visible light which scans the bar code symbol with a sweeping motion.

•

Diode wavelength is 680 NM.

Decode Zone (Vcc = 5V)

Zone1st

Figure 9-1. Decode Zone: Apex II With Standard Integrated Laser Reader

Compsee, Inc. Apex-0698-Part 1: User’s Manual

62 Part 1

Page 63

Apex II with Integrated Laser Reader - Long Range •

Reads bar codes using a non-contact, moving beam, 680 NM visible laser diode scanner.

•

A laser diode emitting visible light which scans the bar code symbol with a sweeping motion.

•

Diode wavelength is 680 NM.

Long Range Decode Zone (Vcc = 5V)

Zone2lr

Figure 9-2. Decode Zone: Apex II With Long Range Integrated Laser Reader

TERMINAL SPECIFICATIONS Environmental Specifications Operating Temperature:

0°C to +50°C (+32°F to +122°F)

Storage Temperature:

-20°C to +60°C (-4°F to +140°F)

Humidity:0 - 90% non-condensing

Mechanical Specifications Weight:

934 lb.

Width:

3.8 inches

Depth:

2.1 inches

Height:

8.4 inches

Compsee, Inc. Apex-0698-Part 1: User’s Manual

63 Part 1