Page 19
OPERATION
All operating functions related to either a Master Control Panel or a Remote Control Panel take place on the front of the unit. The operator controls the system (or the part of the system assigned to a Panel) using these front panel controls.
FRONT PANEL CONTROL
The Control Panel is the operator’s interface to the control system. The operator can observe the status of various functions associated with system operation. Front panel controls include a joy stick for control of the pan and tilt unit, toggle switches for control of zoom in/out, focus near/far, and iris open/close, and pushbutton switches for selection of camera power on/off, lens speed fast/slow, and auto/manual iris.
Available as options are three auxiliary switch positions for operator defined control, a maximum of three relays and/or one analog output for special system control. These switches are not shown in the front panel view nor listed in the controls table.
MPC CONTROL PANEL
Also included is a keypad for camera and monitor selection. Two alpha numeric LED displays identify the camera and monitor selected. A BUSY light indicates when an attempt is made to select a camera that is being controlled by another operator.
Other LED’s give status of auto/manual iris, camera power on/off, lens speed fast/slow, and the three auxiliary functions.
Tables are included that list all standard front panel functions, a typical camera select/deselect procedure, and a typical control panel select/deselect procedure.
jam) @ @ @ CAM PWR LENS/FAST MANUAL IRIS FOCUS 200M PAN/TILT @ lo) CAMERA CAMERA (e) (e) ©, oPeN_ - sNEAR IN ere BBS wr 6-00 OB CC <©> SELECT Close FAR our ®@®y ®@ Busy elslz seen COMM RESET POWER ENTER ERROR @ @ MONITOR @ COHU ce) oO ©) @® =) a) Figure 3-1. Operator Front Panel Controls 6X-829(A) 19
Page 20
MPC CONTROL PANEL
20
Front Panel Features
Alpha-numeric | CAMERA Indicates which camera is currently selected for viewing display and/or control BUSY Indicates that camera selected is under control of another panrl MONITOR Indicates the monitor to which current camera output is directed to Pushbutton CAMERA Activates camera selection function Keypad SELECT MONITOR Activates monitor selection function (table 3-2) SELECT ENTER Completes the function of selecting a camera or monitor Cc Clears a camrea or monitor select error condition o - 9 Used for numeric input of selected functions Switches and CAM PWR For addressed camera, the switch controls camera Indicators switch & lamp power. Power-on is indicated by a glowing lamp LENS/FAST For addressed camera, the switch controls lens speed switch & lamp for focus and zoom functions. Lamp on indicates fast mode MANUAL For addressed camera, the switch controls automat-ic/manual iris selection. Lamp on indicates manual control mode. IRIS: For addressed camera, this switch opens and/or closes OPEN/CLOSE lens iris when the manual mode is activated FOCUS: For addressed camera, this switch focuses the lens NEAR/FAR closer to or farther from camera ZOOM: For addressed camera, the IN position has the effect of IN-OUT making the subject appear closer on the monitor, the OUT position causes the subject to appear farther away COMM A communication error exists when this lamp is glowing ERROR indicating improper communication to the selected cam- Lamp era control receiver. (This is a normal indication if camera is not a controllable camera.)
RESET Switch
Restarts the microprocessor
PAN/TILT Joy- | For addressed camera, moving the joystick to any posi-stick tion through a full 360 degrees activates the panning (right-left) and/or tilting (up/down) action indicated by the arrows
POWER Lamp _| This lamp glows green when panel is supplied power to the system. (On-off switch is on rear panel.)
6X-829(A)
Page 21
MPC CONTROL PANEL
Monitor Select/Deselect Procedure
MONITOR SELECT
1. Depress MONITOR SELECT
MONITOR display will have a flashing 0 (zero)
2. Enter monitor number
MONITOR display will show the number entered
3. Depress ENTER
Either A or B occurs:
MONITOR display stops flashing and
CAMERA display will indicate the camera assigned to selected monitor
(Command status display will indicate current camera site status)
MONITOR display will continue flashing and BUSY lamp will flash, indicating possible errors such as:
Monitor number is out of range for this control panel, or
Some other control panel has control of the selected monitor output
Clear MONITOR SELECT
4. Depress C
Monitor display will indicate the SELECT number that was indicated prior to depressing MONITOR SELECT
6X-829(A)
21
Page 22
MPC CONTROL PANEL
Camera Select/Deselect Procedure
CAMERA SELECT | 1. Depress CAMERA SELECT CAMERA display responds with a flashing 0 (zero)
2. Enter camera number (1 to 3 CAMERA display responds with the number just en-digits) on keypad tered as a flashing display
3. Depress ENTER Either A or B occurs:
CAMERA display will stop flashing BUSY lamp will indicate busy status
Command status display will indicate current camera site status
CAMERA display will continue to flash and BUSY lamp will flash, indicating an error condition
(The error condition would normally be due to selection of a camera number not available to the control panel) Clear CAMERA 4. Depress C Camera display will have a flashing 0 (zero) SELECT 5. Depress C again Camera display will indicate the number indicated prior to depressing CAMERA SELECT
Control Panel Deselect/Select Procedure
PANEL DESELECT 1. Select monitor number 0 (zero) CAMERA display will blank MONITOR display will indicate 0 (zero)
PANEL SELECT 2. Select monitor using the procedure | Panel becomes active. The monitor just in the monitor select/deselect proce- | selected is active. Control of the camera dure that had previously been selected is re-established
22 6X-829(A)
Page 23
MPC CONTROL PANEL
WARRANTY
Cohu, Inc., Electronics Division, warrants equipment manufactured to be free from defects of material and workmanship. Any part or parts will be repaired or replaced when proven by Cohu examination to have been defective within two years from date of shipment to the original purchaser for standard CCD cameras and one year from date of shipment to the original purchaser for intensified CCD cameras and all other Cohu manufactured products.
All warranty repairs will be performed at the factory or as otherwise authorized by Cohu in writing. Transporta-tion charges to Cohu shall be prepaid by purchaser.
This warranty does not extend to Cohu equipment subjected to misuse, accident, neglect, or improper application, nor repaired or altered by other than Cohu or those authorized by Cohu in writing. Television image pickup tubes, image intensifiers, lenses, and products manufactured by companies other than Cohu are warranted by the original manufacturer. This warranty is in lieu of all other warranties expressed or im-plied. Cohu shall not be liable for collateral or consequential damages.
A Return Authorization (RA) number must be obtained from Cohu prior to returning any item for warranty repairs or replacement.
6X-829(A)
23
Page 24
24
MPC CONTROL PANEL
CoH U
Cohu, Inc./Electronics Division
September 17, 1995 Revision 1 Feb. 17, 1997 Revision 2 Mar. 4, 1998 Revision 3 April 4, 2002 Revision 4 Oct. 16, 2002 Revision 5 Nov. 19, 2002
6X-829(A)
Page 25
APPENDIX A
MPC SYSTEM MESSAGE FORMATS
Two appendices follow this page. They describe the message formats for RS-232 and RS-422 signals used for communications with the Control Panels.
6X-829(A) 25
Page 26
MPC CONTROL PANEL
This page intentionally left blank
26 6X-829(A)