Page 1
COHU, INC. Electronics Division Installation and Operation Instructions
17.0 > a
(431) _ - - | chi a ml a (3) @ @ i or [ol . 3) 13.0 (330) @ (nl { ih 7 wet a a a + e ®
SST
J 0.250 x 0.500 (6.35 x 12.7) SLOT (4 PLACES) (28.7) oO Q @ @ (CAM PWR LENS/FAST MANUAL RIS. Focus 700m PAN/MLT ic), ! “ - /{naccjw 6 § 68866 eAe | monitor <(©)> ABE 4 fs) (2 a] SELECT CLOSE = FAR our <O» 3.00 3.46 sow isis DF © CO J stanovw com ease rowte (76.2) (87.9) QO wowtor ogoRs a ® CcCoHnu o O ° ® | | (=) S|, _ - - DIMENSIONS IN INCHES AND (MM) Dimensions
MPC MASTER AND REMOTE CONTROL PANELS
CoH UW
Cohu, Inc./Electronics Division
6X-829(A) Change 2
Page 2
MPC CONTROL PANEL
OVERALL SYSTEM
The microprocessor camera control (MPC) system is composed of a Master Control Unit, Remote Control Units, and Control Receivers. These Units can be ar-ranged to meet the needs of any CCTV control application.
The MPC transmits control signals over a single twisted pair of wires via RS-422 format (and/or optional DTMF). The transmitter is compatible with existing systems where receivers use either of these transmission formats.
A STD bus is used in the control unit so that standard modules may be employed. This modular design allows a system to be assembled from off the shelf components, yet meet the specific needs of any application.
The MPC system controls up to 254 cameras and/or pan-and-tilt units. Up to 32 control positions can be employed in the system (which then reduces camera capacity to 222).
Up to 10 Home (preset) positions for each pan-and-tilt unit are available as an option. These positions are programmed and selected from the preset control unit.
Receivers and remote controls may be located up to eight km (five miles) from each other in a daisy-chain arrangement, using Belden 9182 twisted pair wire. By using an RS-422 distribution unit, the receivers may also be hooked in a “star” pattern, with each point of the star having up to 32 receivers.
Control Panel Control of the system is performed by an operator via the Master Control Panel or any of the Remote Control Panels. Front panel controls include a joy stick for control of pan-and-tilt; toggle switches for control of zoom in/out, focus near/far, power on/off, and lens speed fast/slow. Available as options are three auxiliary switch positions for operator defined control, a maximum of three relays and/or one analog output or special system control. Also included is a keypad for camera and monitor selection. There are LED displays to identify the camera selected and the monitor selected, and a busy light to show that the camera selected is being controlled by another operator.
There are LED displays for status of auto/manual iris, camera power on/off, lens speed fast/slow, and the three auxiliary functions. The remote control panel communicates with the Master Control Unit using RS-422 and/or DTMF signals over a shielded twisted pair cable.
Master Control Panel to Remote Control
Panel Communication The Master Control Panel communicates with the
Remote Control Panels for operator input, processes these inputs, and sends data to the Control Receivers and video switcher, as appropriate.
Three access modes are available. They are: 1. Equal Access. Any operator can control any available camera at any time. 2. Priority Access. Each control panel has a priority number assigned to it and only the highest priority control panel has control if more than one operator has a site addressed. A front panel busy light indicates that contro] does not originate from that control panel.
3. Queued Access. Control is given in the order re-ceived, i.e., first come, first served.
An available option is partitioning software that assigns to each Master and Remote Control Panel only those cameras and monitors that are available to that panel. If an unallowed monitor number or camera number is entered, an error indication is displayed.
ELECTRICAL CHARACTERISTICS See table for specifications.
MECHANICAL CHARACTERISTICS
The Master Control Panel and Remote Control Panel both mount in a standard 19-inch rack mount configuration requiring 3.25 inches of vertical rack space. Circuit boards mount within this chassis configuration. All operator controls mount on the front panel. All interconnections with the system occur on the rear panel of the chassis.
POWER REQUIREMENTS
A Control Panel can be internally wired for use with either 115 V ac power or 230 V ac power. For either power input, 50 or 60 Hz power can be used. Power is applied through a permanently attached line cord on the rear panel. This power routes through a fuse and EMI filtering to a front panel switch and then to a switching power supply.
6X-829(A)
Page 3
MPC CONTROL PANEL
Specifications
Control Functions
Camera Select, Monitor Select, Pan & Tilt, iris/focus/zoom, lens fast/normal, Iris manual/auto, and optional auxiliary relay closure functions. Relevant functions operator programmable
Typical Options
Auto scan, P&T presets (up to 10), white balance, bright-light limiter, peak/average, multiple RS-232 ports, video switching/sequencing
Communications
With Other MPC Equipment RS-422 (DTMF Optional, Master Only))
With Host Computer (Master Only): RS-232
With Video Switcher (Master Only): Parallel to Matrix 44; RS-232 versions available
Communications Distance
RS-422: Up to 5 miles (8 km) with shielded twisted pair. System options available for fiber optics, microwave, and other long-range methods
Standard Configuration Expansion Capability
223 Camera sites, 32 monitors, and 32 multioperator Master and Remote Control panels. Increased expansions available upon request
Input Voltage 105, 130 V ac, 50/60 Hz or
210, 260 V ac, 50/60 Hz internally configured Input Power 20 watts Surge Protection Power line: 20 joules, peak current 2500 amps
Dimensions
1 for 1 half value pulse width
See figure
Weight
7 Ib (3.2 kg)
Encl
Ambient Temperature Limits
19 inch rack mount, 3.25 inches vertical height
Operating: 0 to 50 °C (32 to 122 °F)
Storage: -40 to 85 °C (-40 to 157 °F)
Ambient Air Pressure
Sea level to equivalent of 10,000 feet (3000 meters)
Humidity 95% relative, no condensation
Vibration 5 to 30 Hz with 0.03 inch total excursion. From 30 to 1000 Hz, with peak random vibrations of 5 g’s without damage or degradation
Shock 5 g’s in any axis under nonoperating conditions, MIL-E-5400T, paragraph 3.2 and
1.24.6
Co hu reserves the right to change specifications without notice
NOTE the
The new version of the Remote Control Panel uses a single Remote Camera Control board (9093-6). This board replaces
(9087-8), and the Interface board (9087-6). Both versions are covered in this manual.
Processor board (9092-0), the Interconnection board
6X-829(A)
Change 1
Page 4
MPC CONTROL PANEL
Model Number Interpretation
None 115Vac, 50/60 Hz 230Vac, 50/60 Hz
R Remote 1
00 ~= - Basic 51+ ~Preset 01 ~~ ‘Bright Light Limiter (Master or Remote) (1 position) 52 RS-232 (Single) 02 BLL/Peak-Avg (Master Only) (2-positions) 53 RS-232 (Dual) 03 Auto Scan (Master Only) (1 position) 54 Video Switching 04 White Balance (Master Only) (3 positions) 55 DTMF (Master Only) 05 BLL/Pk-Avg/W Bal (3 positions)
Note: A front panel can have no more than three control positions
EQUIPMENT SUPPLIED
The following list does not include any optional or special-request items. 1. The Control Panel
2. Manual, Installation and Operation (6X-829(A))
EQUIPMENT REQUIRED BUT NOT SUPPLIED The first five items listed below are the minimum required to make use of a Control Panel. In a abso-lute minimum configuration, only a Master Control Panel, a control receiver, a camera, a monitor, and the appropriate interconnection cables would be required. The preset panel, pan/tilt unit, and other items on the list are not required in a minimum operating configuration.
1. Control receiver . Camera . TV monitor . Interconnection cables . Preset panel . Pan and tilt unit . RS-422 distribution unit
. Host computer
Oo mANI HNN fF WN
. Video switcher 10. ID generator
4 Change 1
DATA COMMUNICATIONS APPENDIX
Appendix A at the rear of this manual contains technical data detailing the RS-232 (publication 6X-5030) and RS-422 (publication 6X-5035) message formats.
WARRANTY Refer to page 23 for the warranty.
UNPACKING AND RECEIVING INSPECTION
This unit was thoroughly tested and carefully packed in the factory. Upon acceptance by the carrier, they assume responsibility for its safe arrival. Should you receive this item in a damaged condition, apparent or concealed, a claim for damage must be made to the carrier. To return the unit to the factory for service, please contact the Customer Service Department for a Return Authorization Number.
If a visual inspection shows damage upon receipt of this shipment, it must be noted on the freight bill or express receipt and the notation signed by the carrier’s agent. Failure to do this can result in the carrier refusing to honor the claim.
When the damage is not apparent until the unit is unpacked, a claim for concealed damage must be made. Make a mail or phone request to the carrier for inspection immediately upon discovery of the concealed damage.
6X-829(A)
Page 5
Keep all cartons and packing materials. Since ship-ping damage is the carrier’s responsibility, the carrier will furnish you with an inspection report and the nec-essary forms for filing the concealed-damage claim.
STATIC DISCHARGE PROTECTION
CAUTION
The Contro! Panel contains sensitive devices that can be damaged by static discharge. Use appropriate static control methods when working inside the control panel.
Components used in modern electronic equip- ment, especially solid state devices, are susceptible to damage from static discharge. The relative sus-ceptibility to damage for semiconductors varies from low with TTL to high with CMOS. Most other semiconductors fall between TTL and CMOS in suscepti-bility to static discharge.
As a minimum, therefore, observe the following practices when working inside this or any other electronic equipment:
1. Use conductive sheet stock on the work bench surface.
2. Connect the sheet stock to ground through a 1 megohm or greater value resistor.
3. Use a wrist strap connected to ground through a 1 megohm or greater value resistor when working at the bench.
4. Maintain relative humidity of the room above 30 percent. This may require a room humidifier. Working on circuits with relative humidity below 30 percent requires extraordinary procedures not listed here.
5. Use anti-static bags to store and transport an ex-posed chassis, circuit boards, and components. Use new anti-static bags. Old, used bags lose their static protection properties.
This list serves as a reminder of the minimum ac-ceptable practices. Be sure that all static discharge devices at the work bench are properly installed and maintained.
Standard grounding mats and wrist straps pur-chased for use at work benches are supplied with leads having current limiting resistors for safety. Never substitute with a grounding lead not having the resistor.
6X-829(A)
Change 1
MPC CONTROL PANEL
INSTALLATION PROCEDURE
Installation Summary
This section is intended as a general overview of the procedure for installing a control panel. It as-sumes the Control Panel may not be properly set up for use in the system. If this is the case, internal jumpers may have to be repositioned and some DIP switches may have to be reset.
After all initial settings are made, the panel is then turned on for a functional test.
Additional information about these procedures follows this summary of the installation procedure. Do not begin the installation without referencing the subsequent sections that provide detailed instructions about the installation. This list is merely a summary of the installation procedure.
Read the following six steps to obtain a general overview of installing the Control Panel. The figure shows a typical rear panel for a Master Control Panel. A typical Remote Control Panel would not have the PARALLEL connector. This connector ap-pears only on Master Panels that must interface with a video switcher. A typical installation sequence is as follows:
1. Removing the top cover at an anti-static test bench and setting up internal jumpers and DIP switches for the desired operating conditions. Rein-stalling the cover.
2. Installing the Control Panel in a 19 inch rack. 3. Connecting cables to the rear panel
4. Programming required parameters for the system - using the front panel keypad.
5. Performing a functional test using the Master Control Panel to operate the control receiver(s).
6. Release the Control Panel for use after successful completion of all performance tests.
This completes the summary description of a typical Control Panel installation. Note that either a control receiver or a Remote Control Panel can be connected anywhere in the system.The RS-422 distribution unit figure shows typical system interconnections using an RS-422 distribution unit. Note that using this distribution panel allows up to 10 separate daisy chained paths of control receivers and Remote Control Panels. The maximum number of addressed units in the system is limited to 255.
Page 6
MPC CONTROL PANEL
MASTER PANEL OPTIONS ONLY
OPTION FOR HOST COMPUTER OPTION FOR VIDEO SWITCHER OPTION FOR VICON VIDEO SWITCHER
(PIN1-WITH CONNECTOR ORIENTATION SHOWN) OPTION ne, - om) RS232B RS232A PRESET on) | a ron ® a) ‘e] o © RS422 AS422 O °° ° ° OUT IN 9 GND ge ge g8 o oso j=) | in ) (on on oC) CO 115 VAC LINE CORD
3 CONDUCTOR
Figure 2-1.
Power Input Line Cord
Plug the line cord into any standard three-wire grounded type 115 V ac 50/60 Hz outlet (or 230 V ac outlet if that option is being used). This input power is fused on the rear panel.
CAUTION
Do not apply voltage outside the recom- mended operating range of the CCU (115 V ac or 230 V ac 10%, depending on the option.
PARALLEL CONNECTOR
The PARALLEL connector allows a Vicon video switcher using a parallel interface to be connected to a Master Control Panel.
RS-232B CONNECTOR
This connector is typically used to connect a serial video switcher to a Master Control Panel. Special firmware is required depending on the switcher used.
RS-232A CONNECTOR
This connector is typically used to connect a host computer to a Master Control Panel.
RS-232 MESSAGE FORMATS
In appendix A is a description of the RS-232 interface. Also in appendix A is a description of the RS-422 interface.
6 Change 1
Connectors, Rear Panel
PRESET CONNECTOR
Any Master or Remote Control Panel can be inter-connected with an optional preset panel. A preset panel has 10 pushbutton switches that can be used to re-establish any of 10 previously locked-in positions of a pan/tilt unit a a later time.
A preset panel switch is programmed to “remember” a pan/tilt position by setting its toggle switch to PGM (program) mode and then pressing the desired pushbutton switch. The toggle switch is then returned to its RUN position for the normal operating mode position.
RS-422 OUT CONNECTOR
This connector is paralleled pin-for-pin with the RS-422 connector labeled IN. These two RS-422 connectors provide for a “daisy chain” cabling connection, such that the panel can be connected anywhere along a cable run.
RS-422 IN CONNECTOR
The RS-422 input connector provides an interface with other MPC equipment in the system. Signals in and out of this connector route through the data line surge protect board. This connector is paralleled with the RS-422 connector labeled OUT.
CONTROL PANEL ADDRESS (BINARY) SWITCH S1
Each item of equipment connected on the RS-232 and RS-422 lines must have a unique address. This address is established by an 8-pole DIP switch (S1) on the processor board inside both the Master Control
6X-829(A)
Page 7
MPC CONTROL PANEL
HOST A239 A240 GEMOTE rN COMPUTER CO- - - - - - L) comeuTeR CI- - - q ps |] Y PANEL 1c} J MASTER CONTROL PANEL INCLUDING « MASTER CONTROL PANEL LAST CONTROL o9 o} - “* 47] recever 1-1) Unit CA241 os [C- - - 10] “NGprionaL) | aS, _ - _ J CABLE SUPPLIED WITH MATRIX 44 | a | | a | VIDEO SWITCHER (MATRIX 44) Typical Interconnection Cabling (without RS-422 Distrubution Unit) Panel and the Remote Control Panel. This switch front right of the Remote Camera Control board in setting is “read-in” by the Control Panel address the new style Remote. circuit only during power up or reset. When setting The default Control Panel address setup is 1. Refer the address, always turn power on and off or use a reset to the Decimal-Hex-Binary Conversion table to deter-button to ensure that the address is read in. mine the binary switch settings for the desired address. To set the DIP switch, first remove the cover by loosening all nine screws around the cover. Refer to 2-WIRE / 4-WIRE JUMPERS the figures for the locaton of switch S1. It is an In 2-wire mode, one twisted-pair is used for the eight-pole DIP-switch positioned on the processor RS-422 control signal. Communication is bi-board in the card cage located behind the front panel directional over the single twisted-pair. In 4-wire on the Master and the old style Remote, and on the mode, two twisted-pairs are used, one for transmit-ting data, and the other for receiving data. The
6X-829(A) Change 1 7
Page 8
MPC CONTROL PANEL
CONTROL RECEIVER CONNECTS TO ] AN RS-422 DISTRIBUTION UNI
R AMASTER CONTROL PANEL
U - - =1 BNC cai
S)
CA-236
1 Ot)
CA-238 OR CA-245
| OX tf
75 OHM COAX
WITH 150 OHMS
(NOMINAL)
CAMERA
I Oh VIDEO TO A MONITOR, SWITCHER,
OR OTHER DEVICE
KO BELDEN 9182 CABLE CABLING FIELD WIRED TO FORM "DAISY CHAIN" E: CONTROL ] CONTROL RECEVERS SHOWN CD RECEIVER REMOTE CONTROL PANELS r CAN BE USED AT ANY POSITION Ler] IN THE "DAISY CHAIN* [ BNC I] rt> CONTROL RECEIVER >) 3, lail anc [] a>) CONTROL |] = RECEIVER 31 ] {| BNC il TERMINATE PINS D TO E
Typical Control Receiver Interconnections
6X-829(A)
Page 9
MPC CONTROL PANEL
HOST COMPUTER [| (OPTIONAL) CA239 CONNECT REMOTE TO EITHER A242 pe CONTROL UNIT rs-422_ 1) [+ - - L]1 Ion JH 3 [ os OK - DISTRIBUTION PANEL 34 unit 201k MASTER sjCOK4 CONTROL ) PANEL 40CI-4 siCK REMOTE CONTROL PANELS AND Loon CONTROL RECEIVERS CAN BE 6JLI-4 MIXED IN ALL 10 LINES 150 OHM 71CI- - ” JUST HAVE . ! Mi TERMINATION sik AT PIN4 OR 5 CONTROL UNIT )C- - - recever ICI} 31 CA243 1 p25 |], - - CA241 PRESET PANEL NOTE: PRESET PANELS CAN BE CONNECTED q (OPTIONAL) TO ALL CONTROL RECEIVERS CABLE SUPPLIED WITH MATRIX 44 ed 1 VIDEO SWITCHER
(MATRIX 44 TYPICAL)
Typical System Interconnections, RS-422 Distribution Unit Connections
2W/4W jumpers are located on the Data Line Surge Protection board. The Remote Camera Control board in the new style Remote Panel also has 2W/4W jumpers. These should always be in the 2W position.
RS-232 COMMUNICATIONS BAUD RATE
A Master Control Panel can be optioned with one or more dual-channel RS-232 cards. Each card provides two ports. Each communication port baud rate can be independently set from 150 to 19200 baud, as shown in the listing below. Baud rate is established by two 8-pole DIP switches on the RS-232
6X-829(A)
Change 2 board inside the Control Panel. These switch settings are “read- in” only when the Master Control Panel is powered up or reset.
To set the DIP switches, first remove the cover by loosening all nine screws around the cover and lifting it off. Then locate the RS-232 board. It will be in the card assembly behind the front panel keypad and numberic display. The board will have two 8-pole DIP switches designated as channel | and channel 2. They are labeled with the following baud rates: 19200, 9600, 4800, 2400, 1200, 600, 300, and 150. The default CCU baud rate setup is 9600 for each bank.