For the Cohu 9905
Page 61
Networking your vision
The maximum dimension allowed for a logo file is: PAL: 720 X 288 NTSC: 720 X 240 And a legal file name must follow the old DOS file naming convention.. (8 chars or less with or without a 3 char extension)
Figure 5-7 : Logo on screen display
VMD - Video Motion Detection Enabling the VMD option for a selected 9900 unit, will activate the Video Motion Detection mechanism. A sudden motion in the specified region of the video frame will trigger an event, and a text string will appear on screen. In this tab the user can adjust some additional parameters tuning the behavior of the VMD: The number of frames to wait since motion has been detected before VMD event is fired. The number of frames to wait since motion has ended before VMD event ends. Direction of motion to be detected Right-Left, Left-Right or all.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 61 of 93
Page 62
Networking your vision
Region of interest specified by an (X, Y) point, Width and Height creating a square. Any motion occurring outside that region will be ignored. The region of interest may be displayed (as a colored square) by explicitly enabling this option in the VMD tab.
Figure 5-9 : VMD parameters
PTZ All PTZ settings for the currently selected camera (from list A) are displayed along with button controls for controlling directional movement (Up Down Right Left) as well as Zoom and Focus of the PTZ camera. Preset positions are available (first 9 of which are represented directly by clickable buttons), and may be set by moving the camera to the desired position, selecting a preset number from the list, and finally pressing the SET button.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 62 of 93
Page 63
Networking your vision
Figure 5-10 : PTZ Preset
In the settings frame, the following PTZ parameters are displayed: •
PTZ protocol (example: 18 = Cohu I-series Positioners).
•
COM port 2.
•
Camera address 1.
Discrete I/O The Discrete I/O Configure & Test window is intended to allow the user to check the reception of alarms and the activation of external devices through the Digital Input\Output ports of the units. Also a transparent connection between a left side and a right side unit may be set and checked pressing the connect button at the bottom of the form. The connection status Connected/Disconnected is displayed at the bottom of the form.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 63 of 93
Page 64
Networking your vision
Figure 5-12 : Discrete I/O and transparent connection
Alarms A selected subgroup of alarms may be enabled\disabled by checking\unchecking the checkbox control next to the alarm name and clicking APPLY.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 64 of 93
Page 65
Networking your vision
Upon disabling an alarm the application will no longer receive event strings from the unit until the alarm is enabled again. Following a fired event (Example: motion detection) the unit will send up to 10 event strings in a sequence, or until an ACK signal is sent to the unit. If the ACK checkbox is checked only one event string will be sent. The event strings are displayed in a scrollable list, and may be cleared at any time. The string contains the Unit's name, date and time of the triggered alarm.
Figure 5-14 : Alarm Log
On this tab, the user may simulate discrete input alarms by pressing one of the 4 buttons next to the alarms settings list. Pressing a button will initiate an input alarm, and a trigger will be fired from the unit accompanied by an event string. The string will be displayed on the alarm log list.
Figure 5-15 : Alarm Simulator Window
UPDATE FIRMWARE In this form the user may retrieve update or reset the firmware of the selected unit. The user must first make sure the unit is properly connected to the network and then enter its IP Address. In order to retrieve data from the unit, press the GET button and wait for the data to download via the FTP protocol to the local disk, then press the EDIT button to display the data in a text editor Where you can modify data and parameters, and finally press PUT to write your changes back to the unit. Make sure to specify the correct 9900 series unit type before retrieving or writing data to the unit.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 65 of 93
Page 66
Networking your vision
BIOS may be updated 9900 units, after entering User Name and Password. Codec software may also be updated. (See figure 5-16). File names for 9900 units: •
Software: VxWorks.bin.
•
BIOS:
Codec.out.
Unit reset (which lasts 20-30 sec’) will take place following any software update, or modification of Application or Network parameters, via the Taskaman.ini and Status.txt files. The user should wait for the reset process to complete.
Figure 5-16 : Configurator: Firmware update. Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 66 of 93
Page 67
Networking your vision
RECORDERS: Add\Edit\Remove Allows the user to define new recorders (9950 NVR applications) for the system. Each recorder has a single database file (Video.mdb) into which it writes the details of every AVI file it records (Name, Date\Time, Location, and Camera). The Network path to this file should be specified by the user. In the second field the user must add the Network path to the recorded AVI files themselves .The Recording application is responsible for sharing this path across the network. Finally the user should assign a unique name to the new recorder. An existing recorder may be edited or deleted pressing the EDIT or REMOVE button respectively
USERS: Add\Edit\Remove This form should be used to add new users to the system, or edit\delete defined users.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 67 of 93
Page 68
Networking your vision
Figure 5-20 : User Configuration
A new user is assigned a unique Login ID, Password and some optional details (phone number, name and Email). After entering the required fields and properly confirming the password, the OK button should be pressed to add the new user to the Database, At this stage, the new user may be granted access to sites by selecting a site from the list of sites. Select the check box next to the site to add this user to that site. To remove a user, select the user from the list and click the REMOVE button. The new defined user may use any application by entering his Login ID and password and have access only to the sites which appear on his user’s list of sites. If no sites are defined in the system, or the user has no access rights to any site, he will still be able to login into applications but will have no devices to access, and thus will not be able to perform any functions such as recording and viewing live or recorded video. To modify user details or add\remove subscribed sites, select ‘EDIT’ from the Users Configuration dialog, and the same ‘Add New User’ dialog will appear displaying the current details of the selected user, along with his subscribed sites.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 68 of 93
Page 69
Networking your vision
Figure 5-21 : User details.
Note: Devices recorders, sites and users may be added edited, or deleted later at any stage, using the System Configurator. The changes will be reflected in other applications by applying the Configuration Refresh function described earlier.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 69 of 93
Page 70
Networking your vision
9991-0900 CONSOLE MANAGEMENT SOFTWARE The 9905-0100 Console, COHU state-of-the-art management package, monitors and controls surveillance applications with Cohu 9900 Series multimedia gateways. The 9905-0100 Console Management Software is installed on a workstation in the control center, which provides the operator with a graphical user interface. The 99050100 Console Management Software is running according to the Configurator’s predefined database. The operator can view the site map and control, the station in real-time as well as the remote surveillance hardware devices located at the site. The main functions of the 9905-0100 Console Management software are: ◦
Site mapping and visual display on the control workstation monitor.
◦
Control of remote sensors, cameras, audio and data devices
◦
Predefined events and incident alarms
◦
Information reports and activity log
◦
Video transmission control
For more detailed information about the 9905-0100 Console Management software, refer to the 'COHU Management Suite User Manual'.
9905-0100 VIEWER The 9905-0100 viewer is a desktop application that allows users to connect to video cameras and view live video pictures (currently up to 4 cameras simultaneously), search and display video files from local disk or files recorded by StreamR applications. As well as capture live video into local AVI files or single frame snapshot BMP files.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 70 of 93