Page 91
Networking your vision
Software Update Settings continue: FTP host name (FTP Server).
FTP Host Name
: fred
Read/Write
FTP username
: fred
Read/Write
FTP password
: Cohu
Read/Write
Changeable by user. FTP Server and MediaRacer unit username. Changeable by user. FTP Server and MediaRacer unit password. Changeable by user. LM 80 Temperature inside the box
Temperature = 51.5 Celsius (124.7
Read only
Fahrenheit) 2.5 volt status
IN0: 2.50 V (2.5)
Read only
3.3 volt status
IN1: 3.32 V (3.3)
Read only
5 volt status
IN2: 4.98 V (5.0)
Read only
Not Used
IN3: 0.00 V (0.0)
Read only
Not Used
IN4: 0.00 V (0.0)
Read only
FAN Status (Not Used)
Fan 1: 0 RPM, Fan 2: 0 RPM
Read only
Flash Dir display size date
--------
------
2132272
MAY 13 2004 17:22:54 time ------ name --------
VXWORKS.BIN 1810250
MAY 13 2004 17:27:52
CODEC.OUT 0
APR 20 2004 14:38:20 VER
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 91 of 93
Read only
Page 92
Networking your vision
APPENDIX C ALARM (DISCRETE I/O) APPLICATION NOTE Product: Application Note:
Cohu 9900 Series Using the 9900 units Dry Contact Inputs and Optoisolated Discrete Outputs ports.
DISCRETE INPUTS: The 9900 units discrete inputs ports are dry contact type inputs, and therefore they are intended to use with general-purpose SPDT switches. Each input port contents two terminal, which are connected directly to SPDT, switch two ends.
DI 1 DI 2
+ + -
Discrete Input Circuit
OPTO-ISOLATED DISCRETE OUTPUTS: The outputs on the 9900 units are optically isolated from the system ground and voltage. In order to drive the relay coil, external voltage and ground should be supplied (see DO Output figure below). One end of the external relay coil is connected to ground while the second end is connected to the negative pin of the 9900 DO terminal and limits the port’s output collector current. The positive 9900 DO terminal is connected directly to the (+) terminal of a power source.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 92 of 93
Page 93
Networking your vision
The maximum output current, common voltages and resistor values are as follows: 1. The absolute maximum supplied voltage shall not exceed 24VDC. 2. The absolute maximum rating output collector current shall not exceed 100ma. 3. The MediaRacer® output operating current is 90ma maximum.
P.S. VCC +
+ Common
-
RELAY
Opto coupler inside the MediaRace r MediaRracer P.S. GND -
DIO OUTPUT
N/C
N/O
Discrete Output Circuit Warning: Drawing operating current out of a DO port above the absolute maximum (100ma) may cause permanent damage to the unit.
Following is a table of common voltages and the examples of minimum relay coil resistances value required in order to drive the relay circuitry.
Input Voltage (DC)
5V
12V
24V
9900
60 Ohm
150 Ohm
300 Ohm
Minimum Coil Resistance Value for DIO Outputs
Note: Pay attention DIO outputs are polarity sensitive. For polarity pin descriptions please see Chapter 3 Specification and Features.