Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 3

7210 Series IEEE-1394a Camera Installation and Operation Manual, pages 9 to 16

Pages 9 to 16 of 24

The original document is the PDF (699 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Cohu 7212

Page 9

Preliminary 1 4-20-05

7210 CAMERA

INSTALLATION AND OPERATION

CAMERA Opto-isolated Board

10-PIN RJ-45 CONNECTORS

Strobe 4 Out

1

1

Strobe 4

Strobe 3 Out

2

2

Strobe 3

Strobe 2 Out

3

3

Strobe 2

Strobe 1 Out

4 5

4 5

Strobe 1 Trigger (anode)

+

6

6

Trigger (cathode)

-

7 8

7 8

Vcc + 8

9

9

9

10

10

10

"11"

"11"

Tab 2 "12"

"12"

Trigger Input (scene capture) Vcc Input (for strobe outputs)

Tab 1

Notes:

Emitter Followers Strobe Outputs from Camera Load Resistor Required

Trigger into 390 Ohms 5 mA min (6.3 to 10 mA prefered) Strobe Power To Camera (Vcc +)

no connection

Ground

Strobe outputs are emitter followers that must have an external resistor to limit current and develop signal Triggering causes the camera to capture an image and provide it as output on the IEEE-1394a cable Strobe and triggering are optoisolated from other Camera circuits Strobe circuits receive Vcc power from the external strobe-power source RJ-45 Tabs ("11" & "12") are common/ground connections making a mechanical connection with the cable shield on sides of plug and circuit board mounted receptacle Be aware that Ethernet cables cannot be used. Ethernet uses 8 pin connectors of the RJ-45 series.

Figure 7. Auxiliary Input (10-pin RJ-45) Cable Diagram

6X-1052

9

Page 10

Preliminary 1 4-20-05

7210 CAMERA

INSTALLATION AND OPERATION

Table 3. Items Supplied

Table 4. Item Typically Required But Not Supplied

ITEMS SUPPLIED Item

Description

ITEMS TYPICALLY REQUIRED BUT NOT SUPPLIED Cohu Part Number

Items 1 and 2 supplied only when the Auxiliary Mount option is selected with camera order 1

Mounting Block (mounts to top or bottom of Camera)

8476505-001

2

Screws (2), Pan Head, 2-56 x 3/16

0310039-002

Viewer/Control Software on CD

Cohu 7200 Viewer

3

Note: Items 1 and 2 can be ordered separately as kit 8476-5. Item 3 is shipped with camera or can be downloaded from the cohu-cameras.com web site.

2. Prepare the PC by verifying that it has an IEEE1394a port with power output and also the appropriate software to communicate with the camera

ITEM

Description

Characteristics

1

Lens, C-mount (manual iris only)

For 1/2-inch sensor

2

Cable, IEEE-1394 (must supply power)

6-wire version to supply power

3

Cable, Auxiliary (optional)

Auxiliary cable for using the triggering and strobe functions if desired. Mates with RJ-45 connector on rear panel

4

Power source for strobe functions (Vcc). Noiminal 5 V dc at apporoximately 25 mA.

Via pin 7 of RJ-45 connector. Return line(s) are the strobe outputs. (Open collector)

5

Video monitor

Compatible with PC video output

6

PC, laptop or other

6-wire (powered) IEEE-1394a

7

Alternate Camera Control Software

National Instruments Lab View, or custom software written / modified for the 6100

3. Install a C-mount lens on the camera suitable for use with a 1/2-inch sensor. 4. Mount the camera 5. Connect the 1394a and if required the auxiliary cable 6. Obtain a picture from the camera. This requires use of the Viewer GUI software operating on a PC. See section 3.0 for Operating instructions. 7. Adjust mechanical back focus by rotating the lens and C-mount if required. See section 2.8.3. 8. Make any other adjustments to focusing and mechanical alignment if required.

2.6.2 RJ-45 10-pin Connector

If either the scene capture triggering input or the strobe functions are to be used for illuminating the scene, plug in the auxiliary cable connector to the 10-pin RJ-45 type connector This connector has grounding tabs on each side. Thus, the mating cable plug also must have grounding contacts on the sides to which the cable shield is connected. Note: This is not an 8-pin version the RJ-45 series of connectors used with Ethernet connections. Ethernet cables will not work. 2.6.2.1 Trigger Input

9. Perform an operational test of the camera functions. Sections 2.8.1 through 2.8.4 provide additional installation instructions about the rear panel connectors, and other features.

2.6.1 IEEE-1394a 6-pin Connector

Plug the 1394a cable into the rear panel 1394a connector. Be sure the plug is properly oriented. Attempting to force it in improperly oriented could possibly apply voltage to the data and trigger lines and damage them.

10

The trigger input (figure 8) is used to capture a scene at a chosen moment in time using an external hardwire connection. (The trigger function can also be implemented with the Viewer software.) This input is independent of the strobe outputs and their Vcc power input. Triggering is optoisolated from other camera circuits. Pin 5 of the RJ-45 auxiliary connector connects through a 390 ohm resistor to the anode of a photodiode inside the camera. Pin 6 connects to the cathode of that diode. A minimum of 5 mA is recommended to drive this photodiode,

6X-1052

Page 11

Preliminary 1 4-20-05

7210 CAMERA

INSTALLATION AND OPERATION CAMERA

Table 5. Cables Required D E S C R IP T IO N

CAM E RA C O N N E C TO R

M AT IN G CABL E P L UG

IE E E -13 9 4a

6 -p in IE E E -1 3 9 4A

6 -p in IE E E -13 9 4 a

1 0 -p in RJ-45 with sid e gro und tab s

1 0-p in RJ-4 5 p lug with sid e g round ta b s co nne cte d to ca ble shie ld

A uxilia ry

Opto-isolator Board

Rear Panel RJ-45 Connector 4 3 2

N o te : T h is tab le lists o n ly ca b le s co n n e ctin g d ire ctly to the C a m e ra. Oth e r ca b le s will b e re q u ire d fo r in terco nn e ctio n s with o the r e qu ipm e n t . S e e figu re 6 fo r a typica l insta lla tio n .

Strobe 1

1 2 3 4

Current Limiter to protect emitter follower 100 ohm 10 mA but for long term reliability it is better to use a minimum of 6.3 to 10 mA. Applying a TTL level 5 volts to the input would produce about 13 mA drive current.

Vcc

7

390 ohm

+ Vcc (5 V typical)

560

2.6.2.2 Strobe Outputs and Vcc Input

Using the strobe outputs requires that they be provided with their own input power (Vcc) on pin 7 of the RJ-45 auxiliary connector. These four outputs are isolated from other Camera circuits by a four stage optoisolated IC inside the Camera, and thus the strobe outputs require their own power from an external source to maintain this isolation. Each of these four outputs is direcly driven by an emitter follower transistor inside the camera (figure 9) without any current limiting resistor. An external current limiting emitter resistor must be provided outside the camera for each of these outputs or the internal transistors will be damaged. Figure 9 shows a typical circuit using a 100 ohm current limiter into a 390 ohm load resistor.

Opto Isolator Board

CAMERA REAR PANEL CONNECTOR

RJ-45 390 Camera Scene Capture

5 + Trigger 6 - Input

5 mA min

TRIGGER INPUT FUNCTIONAL CIRCUIT

Note: Trigger can also be implemented in software

Figure 8. Trigger Input Functional Diagram

6X-1052

Typical for Strobe Outputs (4)

CAUTION: Shorting a strobe output to ground with Vcc applied will destroy the internal emitter follower transistor

Figure 9. Strobe Output Functional Diagram

With 5 V dc applied for Vcc the approximate current through the internal emitter follower and external resistors would be 10 mA (1/4 W). Continuous current drain from a strobe output should be limited to a maximum of 35 mA in an installed operation when the Camera is in service. So long as the load driven by a strobe output does not short to ground, otherwise exceed the maximum currrent limtation, or backfeed any damaging voltage spikes the suggested load circuit shown in figure 9 can be modified as desired. 2.6.3 Lens Back Focus

After the C-mount lens is fully threaded into the camera body no back focus tracing is required. 2.6.4 Strobe Timing Reference

The strobe outputs must have their timings set (figure 22) to produce scene illumination

11

Page 12

Preliminary 1 4-20-05

7210 CAMERA

INSTALLATION AND OPERATION Table 6. Drop-down Menu Selections

Camera

Mode

Rate

Check Link Select Camera Init Camera

1280x960 Mono (16-bit)

7.5 pfs

Cohu Camera Reset

Help About 1394Cohu Demo... Debug Setting

Set Serial Number Partial Scan

Camera Model Maximum Speed

Draft Mode

Show Camera Stop Camera Mirror Camera Control Strobe Setup One Shot Test Pattern Save Image External Image Positive Edge Negative Edge Both Edges

NOTES

The Mode and Rate columns above show only the items applicable to the model 6100 Camera. Grayed-out items that appear in the actual drop down menus are not listed here. In the Camera column, certain items in the actual drop down menu will be grayed out depending on the selections currently in effect

Exit during the time when the sensor is integrating an image. Timing illustration A in figure 10 shows that the full sensor integration period is available when the Camera (sensor) does not have a shutter period selected. Illustration B in figure 10, however, shows that when the Camera is set for a typical shutter period of about one-half the normal period, the initial period of sensor integration is constantly being cleared by a string of pulses. The sensor is only allowed to integrate an image of the scene after these clearing pulses end. The remaining time would be the shutter period selected. It is during this period that the strobe outputs can be set to “fire” strobe lights on the scene. The important thing to note is that the shuttering time selected occurs at the end of the normal integration period of the sensor, not during the initial period when the sensor is constantly being cleared. The clearing stops at the time in the when the shuttering time selected remains in the vertical interval. If the Camera (sensor) has been set for a very short shuttering period, only a very slight integration time at the end of normal integration is available.

12

3.0

OPERATION

Operating the camera consists primarily of making menu selections and settings. The following paragraphs briefly describe the function of each selection.Figure 19 shows a window that opens if the Camera has problems acquiring an image. 3.1

Control Inputs and Outputs

All operating functions of the Camera occur through two electrical connectors are located on the rear panel. One is a six-pin IEEE-1394a interface and the other is an RJ-45 connector used for two functions that may not be used: triggering the Camera to capture a scene and strobing lightin to illuminate the scene. 3.2

Software Control

Viewer software must be used to control most camera functions. The Cohu 7200 GUI Viewer can be used for basic control functions or a third-parts software such as National Instruments Lab View can be used. For some applications it may be preferable to have software

6X-1052

Page 13

Preliminary 1 4-20-05

7210 CAMERA

INSTALLATION AND OPERATION

A. NO SHUTTERING 250 ms Full Exposure Period

EXPOSURE TIME

Strobe timings must be set to illuminate the scene during this interval.

250 MS STROBE TIMES SHOWN DURING 10 INTERVALS WITHOUT SHUTTERING

B. WITH SHUTTERING 4 Frames Per Second Assumed Full Exposure Period Without Shuttering (250 ms for 4 fps)

25 ms EXPOSURE TIME (4 frames per second)

Strobe timings must be set to illuminate the scene during this interval when clearing pulses have ended

EXPOSURE TIME WHEN SHUTTERING (A Shuttering Period of 25 ms is shown) Sensor is constantly cleared for 225 ms by the string of pulses until only the selected shuttering period remains of the normal integration period of the sensor

Strobing must occur during this 25 ms period in the example When clearing pulses end here, sensor is then allowed to integrate an image for the remainder of the exposure period (25 ms) without being constantly cleared.

Exposure Period Selected for Shuttering (25 ms)

25 MS STROBE TIMES SHOWN AT END OF10 INTERVALS

Figure10. Strobe Timing Reference

6X-1052

13

Page 14

Preliminary 1 4-20-05

7210 CAMERA written or modified for the specific application to which the camera is to be used. 3.3

Frame Rates

INSTALLATION AND OPERATION

3.5 4 Camera Model

Clicking on this item causes a window to appear (figure 21) showing the vendor associated with the selected camera, the model number of this camera, and the unique identification number of this camera.

The basic full-resolution (659 [H] x 494 [V]) frame rate of the camera is about 70 frames per second (fps); 30 fps nominal. Increased frame rates are available by selecting the Partial Scan mode to scan fewer lines. As few as 50 lines can be scanned.

3.5.5 Maximum Speed

3.4

3.5 6 Show Camera

Menu Items

Section 3.5 lists each item that appears in the five drop down menus and briefly describes their functions. The descriptions covered in this section are shown in table 6. Some of the menu selections require that Camera operation be halted by the Stop Camera function in the Camera menu. 3.5

“Camera” Drop-down Menu Items

This section briefly describe the various drop-down menu selections available under Camera. See the Camera column in table 6 for a summary of these selections. Table 7 expands on functions of the Camera drop down menu selections. They are also described in sections 3.5.1 through 3.5.10. 3.5.1 Check Link

This selection (figure 17) causes the Viewer software display all available cameras on the 1394a cable. 3.5 2 Select Camera

Placing the menu cursor over this item causes a flyout window (figure 14) to appear showing all the available cameras on the 1394 cable. Click on the desired camera. 3.5.3 Init Camera

Clicking on this item causes the viewer to connect with the camera to determine its various operating characteristics (figure 15).

14

Clicking on this item opens a new window (figure 18) that shows the IEEE-1394 data rate.

Clicking on this item starts camera operation. If the image generated on the picture monitor is totally black or totally white, it may be necessary to change settings in the Camera Control. . . menu item. (Shuttering, Gain, and Brightness may not be properly set for the light level on a scene). 3.5.7 Stop Camera

Stop camera puts it into a “pause” mode and ends output of an image. The Camera must be stopped to activate certain other menu selections. Figure 13 shows the menu after Stop has been selected. Note that Stop is grayed out and Show Camera is active. 3.5.8 Mirror

Mirror causes the image being generated to switch left and right sides. Top-bottom stays the same. 3.5.9 Camera Control . . .

Opens up a new window (figure 16) with slider bars to control Shuttering, Gain, and Brightness. These values can also be changed by using the right and left arrow keys and the keyboard. A shuttering rate cannot be set that is longer than the frame rate currently established. Nominal values: Gain to 215; Brightness to 150; shuttering to 1/30 sec (33 ms shutter period).

6X-1052

Page 15

Preliminary 1 4-20-05

7210 CAMERA

INSTALLATION AND OPERATION

A. Available Strobing Interval Without Shuttering Strobe Reference Edge Sensor Vertical Integration Interval

Strobe Start-time

Forcible End of Strobe Period if Stop is Set Beyond Here Start and Stop of Strobe can be anytime during the vertical interval if there is no shuttering

Selected Start of Strobe Period (Example Start & Stop Times)

Stop is Set to End Strobe Period Here

Note: Start and Stop are set in the viewer software strobe Setup Window This window is accessible from the Camera Drop-down menu. (See Figure 22)

B. Available Strobing Interval when the Camera is Being Shuttered If shuttering has been established the sensor will be prevented from integrating an image during this initial part of the vertical interval.

It will be allowed to integrate an image only during this period (the shuttering period selected)

Typical Start and Stop must be set within this interval if strobing is desired with the shuttering example shown

Figure 11. Strobe Output Field Reference`

6X-1052

15

Page 16

Preliminary 1 4-20-05

7210 CAMERA

INSTALLATION AND OPERATION

3.5.10 Strobe Setup

3.5.16 Negative Edge

Four outputs on the rear panel RJ-45 connector can be used to strobe drive external circuits that operate strobe lights. These outputs could be used to strobe other functions in machine vision applications, too. Clicking on this menu item opens a new window (figure 22) containing four sliding bars to set the start and stop point for each output. The related box must be checked to activate the output. The strobe should not be set for a timing that is not consistent with the existing frame rate or for when a shuttering selection has reduced the initial part of the integration period of the sensor. See section 2.8.4 for shuttering details.

Select negative edge if the camera is to be triggered on the negative-going edge of a pulse or waveform. 3.5.17 Both Edges

When the both edge menu item is selected the triggering input to the camera must have equal positive and negative times. 3.5.18 Exit

Selecting Exit shuts down the camera and exits the Viewer.

3.5.11 One Shot

3.6

When the camera is stopped, this menu item can be clicked to cause the camera to capture a single image and provide it as output.

The following paragraphs briefly describe the function of each selection available under the drop down Mode menu selection.

3.5.12 Test Pattern

3.6.1 659 x 494 Mono (8 Bit)

When the camera is stopped, this menu item can be selected to turn-on a gray scale test pattern output.

This is the maximum full-frame mode for the camera. The grayed-out selections apply to other cameras. The frame rate at full scan is 70/30 frames per second. An increased frame rate can be obtained by using the Partial Scan mode.

3.5.13 Save Image

Selecting this item prompts for a storage location and image file type (bmp or tif). 3.5.14 External Trigger

The camera can be externally triggered either by a rear-panel hard wire input on the RJ45 connector or by a software input from the Viewer. This causes the camera to obtain an image at a desired moment in time and provide that image as an output. When this menu item is selected, three other choices become available: Positive Edge, negative edge, and Both. (Both is a special function.) 3.5.15 Positive Edge

Select Positive Edge if the camera is to be triggered on a positive-going edge of a pulse or waveform.

16

Mode Menu Items

3.6.2 Partial Scan

Selecting Partial Scan makes it possible to increase the frame rate of the camera. The Camera operates at 70/30 frames per second when all 659 scan lines are being used. Selecting fewer than 659 lines increases the frame rate, though not in proportion. Partial scan can be as few as 50 lines. The Camera must be stopped before the Partial Scan Mode can be selected. Clicking on Menu produces a drop-down list of selections from which the Partial Scan mode can be selected. This opens a new window: Partial Scan Setup (figure 20) which has a slider bar to change the number of lines from 659 to some other value. Using the right and left computer keypad arrows will step the number of lines one at a time. Use the slider to get close, then step with the right/left keys.

6X-1052