Page 1 of 7210 Series IEEE-1394a Camera Installation and Operation Manual

Manual · Cohu

7210 Series IEEE-1394a Camera Installation and Operation Manual

Manual24 pagesPDF 699 KB

Installation and operation manual for the Cohu 7210 series (Model 7212) monochrome IEEE-1394a machine vision camera.

Download the PDF699 KB

Covers · 1 model

The models it covers

Summary

What is in it

The installation and operation manual for the Cohu 7210 series IEEE-1394a camera, including the Model 7212 monochrome progressive scan camera. It gives the sensor, connector and mechanical characteristics with a specification table, then covers the supplied and required equipment, cabling, power over the 1394a cable, the RJ-45 trigger input and strobe outputs, mounting and installation, operating the camera through the Viewer software menus and windows, and handling, static protection and shipping instructions.

Its parts

  1. General Description
  2. Installation
  3. Operation
  4. Handling Instructions

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

The Cohu 7210 Series IEEE-1394a Camera Installation and Operation Manual (Technical Manual 6X-1052, Preliminary 1, April 20, 2005), which describes the Model 7212 monochrome progressive scan camera. It covers the specifications, power over the 1394a cable, the RJ-45 trigger and strobe wiring, mounting, installation and the Viewer software menus.

Read for this summary: pages 1 to 12, 14 and 24 of 24.

Device
Monochrome progressive scan CMOS camera with IEEE-1394a output, controlled from a PC p. 1, 3, 8
Power
12 V dc from the 6-wire 1394a cable at less than 3 watts; powered 1394a sources must supply 8 to 30 V dc p. 7
Connectors
IEEE-1394a 6-pin for video, control and power; 10-pin RJ-45 with side ground tabs for trigger input, four strobe outputs and strobe Vcc on pin 7 p. 3, 4, 10
Sensor
1/2-inch (8 mm) 4:3 monochrome CMOS, progressive scan, 659 x 494 active pixels, 9.9 µm square, freeze-frame p. 3
Trigger input
Opto-isolated, pin 5 (anode, through 390 ohm) and pin 6 (cathode); minimum 5 mA, 6.3 to 10 mA better; software trigger also possible p. 10, 11
Strobe outputs
Four opto-isolated emitter follower outputs, maximum 35 mA continuous; external Vcc on pin 7, typically 3.3 V dc to 15 V dc p. 7
Shutter and gain
Shutter programmable 1/15 to 1/20,000 sec, up to 5 sec integration; gain 0 to 25 dB, manually programmable p. 4
Lens
C-mount, manual iris, for a 1/2-inch sensor; CS-mount lenses cannot be used; no back focus adjustment needed p. 3, 4, 10
Mounting
By the lens or a removable top or bottom mounting block with two 1/4-20 holes; block 8476505-001 and screws 0310039-002, kit 8476-5 p. 4, 8, 10
Software
Cohu 7200 Viewer on CD (also downloadable) or National Instruments Lab View p. 8, 10, 12
Partial scan
Higher frame rates by scanning fewer lines, as few as 50 p. 14
Size and weight
1.35 x 1.73 x 2.84 inches (34.3 x 43.9 x 72.1 mm); 3.7 oz (106 grams) p. 4
Temperature
-5 to 60 °C operating; -20 to 70 °C storage; humidity <95 %, non-condensing p. 4
Replaces
Same optical and mechanical interfaces as the Cohu model 2600 camera p. 3

What this manual walks you through

  • Wiring the 10-pin RJ-45 auxiliary cable for trigger and strobes p. 9
  • Powering the camera over 1394a, including from a laptop's 4-pin port p. 7
  • Mounting the camera p. 8
  • Installation procedure, from lens to operational test p. 8, 10
  • Setting strobe timing against the shutter period p. 11, 12
  • Using the Viewer Camera menu: check link, select, init, show, stop, mirror and camera control p. 14

Good to know

  • Ethernet cables will not work in the 10-pin RJ-45 auxiliary connector. p. 10
  • Each strobe output needs an external current limiting resistor; shorting one to ground with Vcc applied destroys its transistor. p. 11
  • Forcing the 1394a plug in the wrong way round could put voltage on the data and trigger lines and damage them. p. 10
  • A shutter period cannot be set longer than the frame rate in use. p. 14

Questions this manual answers

How is the Cohu 7212 camera powered?

From the 6-wire IEEE-1394a cable: 12 V dc at less than 3 watts, so the PC port must supply power. p. 7

Can I use an Ethernet cable on the Cohu 7212 RJ-45 port?

No; it is a 10-pin RJ-45 with side ground tabs, not the 8-pin type used for Ethernet. p. 10

What lens fits the Cohu 7212?

A C-mount manual iris lens for a 1/2-inch sensor; CS-mount lenses cannot be used. p. 3, 10

How much current does the Cohu 7212 trigger input need?

At least 5 mA, better 6.3 to 10 mA; a TTL level 5 volts gives about 13 mA. p. 10, 11

What software controls the Cohu 7212 camera?

The Cohu 7200 Viewer, or third-party software such as National Instruments Lab View. p. 12

The whole text · 3 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8
  2. Pages 9 to 169-16
  3. Pages 17 to 2417-24

The file

Revision and size

RevisionTechnical Manual 6X-1052, Preliminary 1, April 20, 2005
PublisherCohu Electronics
Pages24
PDF699 KB
TextText from the PDF itself; page 6 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 24

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 24
Page 2
Page 2of 24
Page 3
Page 3of 24

More documents · 1