What is in it
The installation and operation manual for the Cohu 7210 series IEEE-1394a camera, including the Model 7212 monochrome progressive scan camera. It gives the sensor, connector and mechanical characteristics with a specification table, then covers the supplied and required equipment, cabling, power over the 1394a cable, the RJ-45 trigger input and strobe outputs, mounting and installation, operating the camera through the Viewer software menus and windows, and handling, static protection and shipping instructions.
Its parts
- General Description
- Installation
- Operation
- Handling Instructions
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
The Cohu 7210 Series IEEE-1394a Camera Installation and Operation Manual (Technical Manual 6X-1052, Preliminary 1, April 20, 2005), which describes the Model 7212 monochrome progressive scan camera. It covers the specifications, power over the 1394a cable, the RJ-45 trigger and strobe wiring, mounting, installation and the Viewer software menus.
- Device
- Monochrome progressive scan CMOS camera with IEEE-1394a output, controlled from a PC p. 1, 3, 8
- Power
- 12 V dc from the 6-wire 1394a cable at less than 3 watts; powered 1394a sources must supply 8 to 30 V dc p. 7
- Connectors
- IEEE-1394a 6-pin for video, control and power; 10-pin RJ-45 with side ground tabs for trigger input, four strobe outputs and strobe Vcc on pin 7 p. 3, 4, 10
- Sensor
- 1/2-inch (8 mm) 4:3 monochrome CMOS, progressive scan, 659 x 494 active pixels, 9.9 µm square, freeze-frame p. 3
- Trigger input
- Opto-isolated, pin 5 (anode, through 390 ohm) and pin 6 (cathode); minimum 5 mA, 6.3 to 10 mA better; software trigger also possible p. 10, 11
- Strobe outputs
- Four opto-isolated emitter follower outputs, maximum 35 mA continuous; external Vcc on pin 7, typically 3.3 V dc to 15 V dc p. 7
- Shutter and gain
- Shutter programmable 1/15 to 1/20,000 sec, up to 5 sec integration; gain 0 to 25 dB, manually programmable p. 4
- Lens
- C-mount, manual iris, for a 1/2-inch sensor; CS-mount lenses cannot be used; no back focus adjustment needed p. 3, 4, 10
- Mounting
- By the lens or a removable top or bottom mounting block with two 1/4-20 holes; block 8476505-001 and screws 0310039-002, kit 8476-5 p. 4, 8, 10
- Software
- Cohu 7200 Viewer on CD (also downloadable) or National Instruments Lab View p. 8, 10, 12
- Partial scan
- Higher frame rates by scanning fewer lines, as few as 50 p. 14
- Size and weight
- 1.35 x 1.73 x 2.84 inches (34.3 x 43.9 x 72.1 mm); 3.7 oz (106 grams) p. 4
- Temperature
- -5 to 60 °C operating; -20 to 70 °C storage; humidity <95 %, non-condensing p. 4
- Replaces
- Same optical and mechanical interfaces as the Cohu model 2600 camera p. 3
What this manual walks you through
- Wiring the 10-pin RJ-45 auxiliary cable for trigger and strobes p. 9
- Powering the camera over 1394a, including from a laptop's 4-pin port p. 7
- Mounting the camera p. 8
- Installation procedure, from lens to operational test p. 8, 10
- Setting strobe timing against the shutter period p. 11, 12
- Using the Viewer Camera menu: check link, select, init, show, stop, mirror and camera control p. 14
Good to know
- Ethernet cables will not work in the 10-pin RJ-45 auxiliary connector. p. 10
- Each strobe output needs an external current limiting resistor; shorting one to ground with Vcc applied destroys its transistor. p. 11
- Forcing the 1394a plug in the wrong way round could put voltage on the data and trigger lines and damage them. p. 10
- A shutter period cannot be set longer than the frame rate in use. p. 14
Questions this manual answers
How is the Cohu 7212 camera powered?
From the 6-wire IEEE-1394a cable: 12 V dc at less than 3 watts, so the PC port must supply power. p. 7
Can I use an Ethernet cable on the Cohu 7212 RJ-45 port?
No; it is a 10-pin RJ-45 with side ground tabs, not the 8-pin type used for Ethernet. p. 10
What lens fits the Cohu 7212?
A C-mount manual iris lens for a 1/2-inch sensor; CS-mount lenses cannot be used. p. 3, 10
How much current does the Cohu 7212 trigger input need?
At least 5 mA, better 6.3 to 10 mA; a TTL level 5 volts gives about 13 mA. p. 10, 11
What software controls the Cohu 7212 camera?
The Cohu 7200 Viewer, or third-party software such as National Instruments Lab View. p. 12