The text of a manual · part 1 of 2
4810 Series Monochrome Frame Transfer CCD Cameras, Installation and Operation Instructions, pages 1 to 7
Pages 1 to 7 of 14
The original document is the PDF (385 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Cohu 4814, Cohu 4815, Cohu 4812 and Cohu 6315
Page 1
COHU, INC. Electronics Division Installation and Operation Instructions
CAUTION Do not parallel two or more cameras to a common source of 12 (or 24) V ac.
Fig. 1. Di m e n s i o n s LISTED
4810 SERIES MONOCHROME FRAME TRANSFER CCD CAMERAS 5755 KEARNY VILLA ROAD SAN DIEGO, CA 92123-1111 PHONE: 619-277-6700 FAX: 619-277-0221 E-MAIL: INFO@COHU.COM
6X-845(E)
Page 2
4810 CAMERA
INSTALLATION AND OPERATION
NOTE Throughout this manual interpret the following two graphic symbols as indicated: Indicates presence of uninsulated dangerous voltage constituting a risk of electrical shock
CAUTION To reduce the risk of electrical shock, do not remove cover. No user serviceable functions inside. Refer servicing to qualified service personnel.
COMPLIES WITH FEDERAL COMMUNICATIONS COMMISSION RULES AND REGULATIONS PART 15 FOR CLASS A DIGITAL DEVICE NOTE: This equipment has been tested and found to comply with the limits for a Class A computing device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
CAUTION Operate camera only from a UL approved Class 2 power supply.
CAUTION Do not connect more than one camera to a single source of 12 (or 24) V ac power. If the bridge rectifier of any camera fails, all cameras connected to the same source will have their bridge rec ti fi ers destroyed. Also, connecting two or more cameras to a single source can cause hum bars in the video signal.
WARNING To reduce the risk of fire or electrical shock, do not expose this equipment to rain or moisture
CAUTION Do not ground either power input line of the camera when operating with 12 (or 24) V ac input power. Both lines must float. A ground on either input will destroy a bridge rectifier inside the camera.
IMPORTANT SAFEGUARDS b. If liquid has been spilled or objects have fallen into the equipment.
R e a d Instructions - All the safety and operating instructions should be read before the equipment is operated.
c. If the equipment has been exposed to rain or water.
R e t a i n I n s t r u c t i o n s, The safety and operating instructions should be retained for future reference. H e e d W a r n i n g s, All warnings on the equipment and in the operating instructions should be followed. W a t e r a n d M o i s t u r e, Do not use this equipment near water - for example, near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool, and the like. O v e r l o a d i n g, Do not overload wall outlets and extension cords, as this can result in a fire or electric shock.
Servicing - Do not attempt to service this equipment yourself. Opening or removing the cover may expose you to dangerous voltages or other hazards. Refer all servicing to qualify service personnel. Damage Requiring Service - Unplug this equipment from the wall outlet and refer servicing to qualified service personnel under the following conditions: a. When the power supply cord or plug is damaged
2 d. If the equipment does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions. An improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the equipment to its normal operation.
e. If the equipment has been dropped or the cabinet has been damaged. f. When the equipment exhibits a distinct change in performance, a need for service is indicated. Replacement Parts - When replacement parts are required, be sure the service technician uses only replacement parts specified by the manufacturer or those parts have the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other hazards. Safety Checks - Upon completion of any service or repairs to this equipment, ask the service technician to perform safety checks to determine that the equipment is in proper operating condition.
6X-845(E)
Page 3
INSTALLATION AND OPERATION
4810 CAMERA
Table 1. Specifications ELECTRICAL
Imager
Single CCD using frame transfer method
Image Area
8.8 by 6.6 mm (2/3 inch format)
Active Picture Elements
754 (H) by 488 (V)
Number of Picture Cells
780 (H) by 244 (V)
Cell Size
11.5 µm (H) by 27 µm (V)
Resolution
· Horizontal: 565 lines · Vertical: 350 lines
Sensitivity
See table 1a
Contrast Variation, 25 °C
<5% overall
Scanning System
RS-170 2:1 Interlaced
Video Output
1.0 Vp-p, 75 ohms unbalanced
Gamma
0.5 or 1.0, jumper selected
Gray Scale
Renders all shades of gray on EIA tv resolution chart, 1956
Agc
6 dB variable gain (peak-average adjustable); jumper selectable on/off
Auto Lens
Peak/average adjustable
Signal to Noise Ratio, 25 °C
· 50 dB (gamma 1, gain 0 dB), unweighted 8 MHz bandwidth · 55 dB (gamma 1, gain 0 dB), weighted
Automatic Black Level
Maintains setup level at 7.5±5 IRE units if picture contains at least 10% black
Synchronization
· EIA RS-170 crystal, 14.31818 MHz clock output standard · Genlock, with crystal or line lock backup (jumper selectable) · External H and V drive · 12 V dc/ac ±10%, 60 Hz ac · 24 V dc/ac ±10%, 60 Hz ac · 115 Vac 60 Hz, ±10% (with optional wall transformer)
Power Options
Power Consumption
4.2 Watts ENVIRONMENTAL
Ambient Temperature Limits
· Operating: -10 to 50 °C (14 to 122 °F) · Storage: -30 to 70 °C (-22 to 158 °F)
Altitude
Sea level to the equivalent of 3048 m (10,000 feet) [20 inches of mercury]
Humidity
Up to 95% relative humidity, noncondensing
Shock
30 g’s in any axis under nonoperating conditions per MIL-E-5400T, Paragraph3.2.24.6
Vibration
5 to 60 Hz with 0.082 inch total excursion (15 g*s at 60 Hz). From 60 to 1000 Hz, 5 g’s rms random vibration without damage
Dimensions
See figure 1
Weight, less lens
439 grams (15.5 oz)
Type of lens attachment
C-mount
MECHANICAL
6X-845(E)
3
Page 4
4810 CAMERA
INSTALLATION AND OPERATION
Table 1a. Sensitivity, Faceplate Illumination SENSITIVITY
With IR Blocking Filter
Without IR Blocking Filter
Full Video, Agc Off
0.2 fc (2 lux),
0.02 fc (0.2 lux)
80% Video, Agc on
0.07 fc (0.7 lux)
0.007 fc (0.07 lux)
30% Video, Agc on
0.02 fc (0.2 lux)
0.002 fc (0.02 lux)
SPECTRAL RESPONSE
1.1 ELECTRICAL CHARACTERISTICS The Camera features a 2/3 inch format Charge Coupled Device (CCD) image sensor. The sensor uses the frame transfer method with an active imaging area measuring 8.8 mm by 6.6 mm (2/3 inch format). The active imaging area is an array of 754 horizontal by 488 vertical picture elements.
1.2 MECHANICAL CHARACTERISTICS The Camera is a compact, lightweight unit weighing 440 grams (15.5 ounces) without lens. All interfacing connectors are located on the rear panel for easy access. The C-mount adapter
4
MODULATION TRANSFER FUNCTION accepts most types of manual and automatic television lenses. Two 1/4-20 tapped holes are provided on the base for mounting (fig. 1).
1.3 POWER REQUIREMENTS The Camera requires either 12- or 24-V ac/dc input power, depending on the model. The Camera operates from 115-V 60-Hz ac power by using the optional external power pack (fig. 3). If the Camera is to operate from a power supply other than the optional power pack, use a 0.5 amp slow-blow fuse (0.25 amp with the 24-volt version).
6X-845(E)
Page 5
INSTALLATION AND OPERATION
4810 CAMERA
Table 2. Model Number Interpretation
2 4 5
12 V dc/ac 60 Hz 24 V dc/ac 60 Hz 115 V ac 60 Hz*
000 100
None IR-blocking filter (general use)
*12 V ac provided to Camera rear-panel input 2 3 5 7
Genlock - revert to crystal Genlock - revert to line lock RS-170 Crystal Ext. Drive - revert to crystal
Note: Lens Options change on a regular basis. This list is representative of selections
1.4 EQUIPMENT SUPPLIED The following list does not include any optional or special-request items. A lens ordered with the Camera will either be installed on or packed with the Camera. 1. 4810 Camera
0000 None MANUAL IRIS LENSES AL09 9 mm, f/1.4, 2/3" AL12 12.5 mm, f/1.4, 1" AL16 16 mm, f/1.4, 2/3" AL25 25 mm, f/1.4, 1" AL50 50 mm, f/1.4, 1" AL75 75 mm, f/1.8, 1" AUTO IRIS LENSES ES08 8 mm, f/1.4, 2/3" ES12 12.5 mm, f/1.4, 1" ES16 16 mm, f/1.4, 2/3" ES25 25 mm, f/1.4, 1" ES50 50 mm, f/1.8, 1" ES75 75 mm, f/1.8, 1"
If the 115 V ac power pack is shipped with the Camera, the plug for J38 will be installed on the power pack cable. The plug for J32 is supplied only if an auto iris lens is ordered. This plug will be installed on the lens cable. Plugs are not supplied for rear panel connectors in which a cable is provided. These interconnecting cables may be supplied with other equipment.
2. Installation and Operation Manual, 6X-845(E) 3. C-mount adapter 4. Auxiliary connector plug (for J30 on rear panel) 5. Power connector plug (for J38 on rear panel)
6X-845(E)
1.5 EQUIPMENT REQUIRED BUT NOT SUPPLIED The following items are the minimum required to make use of the Camera. A tv picture monitor will be highly desirable for focusing and other adjustments even if the Camera will be used in an
5
Page 6
4810 CAMERA
INSTALLATION AND OPERATION application that does not require direct visual monitoring of the Camera output. If the lens in item 2 is an auto-iris type lens, the proper connector will be required to mate with J32 on the Camera rear panel. Lenses shipped from the factory have the proper connector. 1. 115 V ac, 60 Hz power pack or 12 V or 24 V ac/dc power supply (depending on the model) 2. Television lens, C-mount 3. Auto lens cable plug (Factory supplied lenses have required plug installed) 4. 75-ohm coaxial cable (RG-59/U) 5. Television monitor, composite, monochrome
1.6 UNPACKING AND RECEIVING INSPECTION This item was thoroughly tested and carefully packed in the factory. Upon acceptance by the carrier, they assume responsibility for its safe arrival. Should you receive this item in a damaged condition, apparent or concealed, a claim for damage must be made to the carrier. To return the product to the factory for service, please contact the Customer Service Department for a Return Authorization Number. If a visual inspection shows damage upon receipt of this shipment, it must be noted on the freight bill or express receipt and the notation signed by the carrier’s agent. Failure to do this can result in the carrier refusing to honor the claim. When damage is not apparent until the unit is unpacked, a claim for concealed damage must be made. Make a mail or phone request to the carrier
Fig. 2. Rear Panel for inspection immediately upon discovery of the concealed damage. Keep all cartons and packing materials. Since shipping damage is the carrier’s responsibility, the carrier will furnish you with an inspection report and the necessary forms for filing the concealed-damage claim.
1.7 INSTALLATION PROCEDURE Installation consists of: 1. Connecting power, video, and (if required) sync cables. 2. Installing the lens and checking back focus 3. Setting up internal circuits for the intended application (if required) 4. Mounting the Camera at its location
Table 3. Rear Panel Interface Connectors NAME
CAMERA REAR PANEL CONNECTOR
MATING CONNECTOR FOR CABLE
COHU P/N
MFG P/N
COHU P/N
MFG P/N
VIDEO (J31)
1310242-011
BNC Jack
1310212-001
BNC Plug
AUX. (J30)
1310348-006
Hirose SR30-10R-6S
1310349-006
Hirose SR30-10PE-6P
POWER (J38)
1310356-003
(Switchcraft TB3M
1310356-103
(Switchcraft TA3F
LENS (J32)
1310356-004
Switchcraft TB4M
1310356-104
Switchcraft TA4F
6
6X-845(E)
Page 7
INSTALLATION AND OPERATION
4810 CAMERA
Fig. 3. Power Connections
1.7.1 Power and Video Connections POWER CONNECTIONS, The Camera requires 12- or, optionally, 24-V ac/dc input power. To operate the 12 volt version of the Camera from a 115-V ac 60-Hz power source, use the optional power pack (fig.3). Or, if desired, use a power supply connected as shown in the figure. Be careful of polarity when making dc power connections. A 0.5 amp (0.25 amp for 24 volt version) slow-blow fuse is recommended when not using the optional power pack. When using 12 or 24 V ac input power, be sure that neither of the input lines are connected to a chassis or a transformer frame. Such a wiring arrangement will most likely ground one power input and destroy the bridge rectifier on the power supply board. Also be aware that connecting two or more cameras to a single power source can cause hum bars in the video signal. Each camera should operate from its own step-down transformer, isolation transformer, or from one winding of a multiple secondary winding transformer.
6X-845(E)
CAUTION Do not apply voltage outside the recommended operating range to the Camera. (10.8 to 13.2 V ac/dc, 21.6 to 26.4 V ac/dc, or 103.5 to 126.5 V ac, depending on the version). Be careful of polarity when using dc input power. Polarity reversal may damage the bridge rectifier.
Fig. 4. Auto Iris Lens Connections
7