What is in it
Installation and operation instructions for the Cohu 4810 series monochrome CCD cameras, which use a 2/3 inch frame transfer sensor. The manual gives safety cautions, full electrical, environmental and mechanical specifications, sensitivity figures, model number options for power, filter, sync and lens, the supplied and required equipment, power, video and sync wiring, lens installation and back focus, and the user adjustments and jumpers on the sync, video and auto boards.
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
Cohu installation and operation instructions (6X-845(E), February 1999) for the 4810 Series monochrome frame transfer CCD cameras. The manual is written for the 4810 Series as a whole and does not name individual model numbers. It gives the specifications and walks through power, video and sync connections, lens installation, back focus and the user jumpers and adjustments.
- Device
- Monochrome frame transfer CCD camera, 2/3 inch format p. 1, 4
- Imager
- Single CCD, frame transfer; 8.8 by 6.6 mm image area; 754 (H) by 488 (V) active picture elements p. 3
- Resolution
- Horizontal 565 lines, vertical 350 lines p. 3
- Video output
- 1.0 Vp-p, 75 ohms unbalanced; RS-170 2:1 interlaced p. 3
- Power options
- 12 V dc/ac ±10% or 24 V dc/ac ±10%, or 115 Vac 60 Hz with the optional wall transformer; 4.2 Watts p. 3
- Input voltage range
- 10.8 to 13.2 V ac/dc, 21.6 to 26.4 V ac/dc, or 103.5 to 126.5 V ac, depending on the version p. 7
- Operating temperature
- -10 to 50 °C (14 to 122 °F); humidity up to 95% noncondensing p. 3
- Lens mount
- C-mount; two 1/4-20 tapped holes in the base for mounting p. 3, 4
- Rear connectors
- Video J31 BNC jack; Aux J30 Hirose SR30-10R-6S; Power J38 Switchcraft TB3M; Lens J32 Switchcraft TB4M p. 6
- Synchronization
- EIA RS-170 crystal; genlock with crystal or line lock backup (jumper selectable); external H and V drive p. 3
- Sensitivity
- Full video, agc off: 0.2 fc (2 lux) with IR blocking filter, 0.02 fc (0.2 lux) without p. 4
- Fuse
- 0.5 amp slow-blow (0.25 amp for the 24 volt version) when not using the optional power pack p. 4, 7
- IR filter adapter
- C-ring adapter with IR-blocking filter: 8323501-001 general use, 8323501-002 microscopic use p. 8
- Gamma and AGC
- Gamma 0.5 or 1.0, jumper selected; 6 dB agc, jumper selectable on/off p. 3
What this manual walks you through
- Checking the equipment supplied and the items needed but not supplied p. 5, 6
- Connecting 12 V, 24 V or 115 V power p. 7
- Connecting video to monitors with 75 ohm coaxial cable p. 8
- Installing the lens and cleaning the sensor faceplate p. 8, 9
- Sync, genlock and external drive connections p. 9
- Adjusting back focus p. 9
- Setting the sync, gamma, agc and black level jumpers and balance controls p. 10, 11
- Adjusting auto iris lens level p. 12
- Preparing the camera for shipment and storage p. 13
Good to know
- Do not connect more than one camera to a single 12 or 24 V ac source: one failed bridge rectifier destroys the others, and hum bars can appear. p. 2
- With ac input power, do not ground either power input line; both lines must float. p. 2
- Operate the camera only from a UL approved Class 2 power supply. p. 2
- Line Lock sync mode requires ac input power. p. 10
- With horizontal and vertical drive, the vertical sync may lock up half a line off. p. 9
Questions this manual answers
What power does the Cohu 4810 series camera need?
12 or 24 V ac/dc depending on the model, or 115 V 60 Hz ac through the optional external power pack. p. 4
Can several Cohu 4810 cameras share one 24 V ac transformer?
No. Each camera should run from its own transformer or its own winding, or a failed bridge rectifier can destroy the others and hum bars can appear. p. 2, 7
What is the resolution of the Cohu 4810 camera?
565 lines horizontal and 350 lines vertical, from 754 by 488 active picture elements. p. 3
How do I set the back focus on a Cohu 4810 camera?
Set the lens to infinity, aim at a distant scene with the iris fully open, then loosen the C-mount setscrew and turn lens and mount together until sharp. p. 9
The whole text · 2 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.