Page 131

SECURITY

Transit police officers benefit from the added assistance video ffives. iiy." she says, "These cameras are installed at thousands of sites around the world, and suppott a wide range of security/surveillance and electronic imaging applications." Specifically for the MARTA setup, the 4800 series works well because of the large areas covered by camera surveillance. They're placed in both indoor and outdoor locations, and each camera is encased in a sealed pressurized environment-resistant housing. Cohu 9-inch 9600 series monitors are used in the zone centers. Atlanta has become one of the leading transportation centers in the U.S. In 1837. when the community was originally laid out, it was named Terminus, and it was set up to be the souihem end of a proposed railroad from Chattanooga. Tennessee. By the time of the Civil War. it had been renamed .Atlanta, and had a population some 15.000. Of course it had become a major railroad hub. Because of its strong growth of businesses and city facilities, the city also has attracted many major conventions, including the National Association of Broadcasters iNAB), Providing cameras for transportation centers is not new. But the sheer size and scope of the MARTA system has presented some unique security and surveillance challenges. These challenges continue to be met with the opening of every new station, keeping the flow of rapid rail passengers moving in and around the Atlanta metro area. W « i ; h l . t 4 J InfoCard #75. MARTA Public information Office, (404) 8485116. Laura Sallee. Cohu. 5755 Kearny Villa Road, San Oieeo, CA 92123: (619) 277.6700.

Page 132

ENVIRONMENTAL CAMERAS FOR T R A F F I C SURVEILLANCE by Tim Jones Senior Applications Engineer Cohu Inc./Electronics Division, tends to use the "no nonsense" approach in supplying video for traffic applications. One of the most unique features.Cohu offers for the traffic industry is its variety of ruggedized camera enclosures. These rugged enclosures are sealed and pressurized, and are offered, in either 3", 4.5" or 6" outside diameter. They are purged of oxygen and pressurized with 5 psi of dry nitrogen. Why take these measures? One word: reliability. This insures that the internal circuits ofthe camera and the lens remain free from contaminates, e.g.: humidity, salt, dust and debris normally associated with all traffic applications. In addition to the controlled internal environment for the camera. Cohu installs desiccant bags to insure that no residual humidity is retained in the camera. The environmental enclosures can be equipped with thermostatically-controlled heaters and sunshlelds as a standard configuration. The lens offered in most traffic applications has an auto/manual iris that can be controlled at either the master or remote/local control receivers. Other option available include wiper washer assemblies, low pressure alarm switches, fiber optics and 24character programmable alphanumeric generators. The environmental housing is made of aluminum and painted with a polyurethane paint as a standard.

Continued on reverse

Page 133

The sealed camera enclosure is widely used throughout traffic surveillance systems and is especially useful in areas where humidity is high. By creating a controlled environment for cameras mounted in the great outdoors, the camera has an increased life which will decrease maintenance costs. Cameras sealed in Cohu environmental housing simply cost less to maintain and are more reliable than those without the environmental housing. The specific maintenance costs associated with non-environmental housings are: bucket truck rental, lane closures, and actual replacement costs of camera, lens, and associated hardware. Cohu also features a local/remote Camera Control Receiver (CCR), designed specifically for use in the traffic market. The CCR is designed for installation in a 19" rack frame, (for use in Nema or 330-type enclosures) and is featured with several useful controls. The CCR can interface with either RS-232 or RS-422 communications and features a local/remote control switch. The CCR is equipped with dual RS-232 ports for drop and insert applications. In the remote control mode the CCR will interface with the MPC Master Control Panel via RS-422 or a PC via RS-232 located at the Traffic Operations Center (TOC). In the local mode, the CCR can operate the camera pan/tilt from the site for maintenance, repair and local control when an incident occurs. This eliminates the need for two way radio communications to the TOC. T h e CCR includes a BNC video output on the front panel to allow a local operator to view a monitor while performing tests, as well as a rear BNC connection for standard system operation. In addition to the standard camera pan/tilt functions, the CCR can be easily modified for use with a variety of communication modems and specific system configurations to meet the particular needs of the customer. Additionally, fiber optics transceivers for communications and video can be added. The MPC Master Control Panel will interface via RS-422 over shielded twisted pair to the CCR and will interface with a PC or various other equipment via RS-232. The MPC Master can control most brands of matrix switchers and will interface with several different graphic user interface modules. In a standard configuration the MPC Master Control Panel provides the communication "Back Bone" for up to 223 separate camera sites and 32 remote stations. These are just a few ofthe many reasons Cohu has maintained a high standard of quality throughout the more than four decades of operation. For more information call the Traffic Experts at Cohu or your nearest Cohu sales representative.

Page 134

Image Sensors, the Input Device for Machine Vision Applications Joe Barrett OEM Products Manager Cohu Inc., Electronics Division ABSTRACT - Understanding the technology and capability of image sensors and video cameras allows identifying appropriate imager solutions for measurement applications. This paper examines area array CCD (RS-170) video camera technologies (Frame, Interline) from an operational viewpoint. Camera features (field vs. frame resolution, shuttering, integration, asynchronous reset) are presented in a non-engineering format.

INTRODUCTION The application of video in measurement solutions increases yearly. Understanding the features and benefits associated with video cameras allows a user to select the best technology to achieve the desired result. The goal of this paper is to deliver specific information on camera technologies that allows making an informed decision on integrating the camera into a vision system. Provided is a basic understanding of video cameras for Machine Vision measurement applications. Advantages/disadvantages of the different technology options will be addressed. Information is presented in an operational/applications perspective rather than a design/engineering format. Topics covered include: Technology of area array image sensors, including operation of (Texas Instruments) Frame Transfer, and (Sony) Interline Transfer devices. Field/Frame Resolution, Integration, Asynchronous Reset, and Shuttering as applied to the differing sensor technologies. BACKGROUND CCD image sensors were developed in the early 1970's by Bell Laboratories. The technology has progressively improved, resulting in higher yields, better performance, and lower cost. During the mid 1980's solid state technology surpassed tubes as the primary means of acquiring video images for most applications. Better manufacturing methods and innovative designs are enhancing sensitivity, resolution, and improving signal-to-noise ratio.

Page 135 read from a scan by OCR; it may hold reading errors

ACTIVE IMAGE AREA

OARK REFERENCE

STORAGE AREA

FIGURE 1. CCD SENSOR FRAME TRANSFER

Page 136

The basic video system requires an illumination source, scene or object to view, lens, video camera, and monitor/image processing equipment. The scene is focused onto the imager by the lens, the CCD image sensor wiil conven photons of light to electrons, camera electronics process the image and add timing signals which are output to a monitor for viewing, or image processing system for analysis. CCD IMAGE SENSORS Definition. CCD's are two-dimensional fixed geometry area arrays of photosites. The array contains lines (242 to 485, typical) of pixels (picture elements). Each line contains 510 to IK pixels, the greater the pixel count in each line, the higher the horizontal resolution. The greater the number of lines the higher the vertical resolution. RS-170 video standard limits the maximum number of active video lines to 485. The total number of lines for RS170 is 525, yet only 485 contain image information, the balance of 40 lines are consumed with synchronization signals. Each pixel converts light to an electrical charge. Photons striking the silicon pixel generate a charge proponional to the amount of light present during the integration period (16.6ms, typical). This potential is referred to as a charge packet. Sensitivity is a function of the number of photons striking the sensor, integration time, and the efficiency of the pixel to convert photons of light to electrons. This process is analog and yields a representative analog voltage output from the imager. The difference between sensor technologies is determined by the method of construction, and the path by which the charge packets are transferred from the active array of the sensor chip to the camera circuits. The efficiency with which charge packets of electrons can be transferred (.99995) from pixel of origin to the output without loss makes this technology an excellent measurement device. Timing. Clocking of the charge packets contained within the pixels is at a rate sufficient to read a line (52.4^s) of pixel information while maintaining RS-170 timing. The greater the number of pixels per line the higher the clock speed, (e.g., 768 horizontal pixels; 52.4/iS/768 = 68.2ns/pixel, or 14Mhz clock rate). The charge packets are clocked out of the sensor serially one pixel at a time, line by line. The camera circuits will merge the video information with synchronization signals, providing composite video (RS-170) to a monitor or frame grabber. FRAME TRANSFER RCA pioneered the development of the Frame Transfer CCD in the early 1980's. A Frame Transfer sensor contains two arrays of pixels (fig. 1), one for active imaging, and a second to store the field previously collected during the 16.6ms integration period. Both arrays contain the same number of pixels. The storage register is covered with an opaque material to prevent stray light from changing the contents of any individual pixel during storage or readout.

Page 137

TWO PIXELS h

8.5 u m '

AcnvE PIXILS

CLOCKED WELL

-VIRTUAL B

ER

19.75 u m

VIRTUAL WELL

ANTIBLC .MHG GA.2

STOfUOE pixas

CLOCKED WELL

VIRTUAL WELL AMPUFIER ' neAoat/TREOisTcn •

FIGURE 2. FRAME TRANSFER

FIGURE 3. FRAME TRANSFER

SINGLE COLUMN OF PIXELS

CW REL01 < UNE1

VW FIELD 2 UNE1

CW REL01 V LINE2 ^

=

VW REL0 2 L1NE2

CW RELDI ,UNE3 ^

.

VW FIGURE 4. FRAME TRANSFER PSEUDO-INTERLACE

Page 138

Several columns of pixels in the active image area are also covered with an opaque material. Refened to a "Dark Reference Pixels", their values are used by the camera to provide DC resoration by clamping the video line to a know level. This compensates for changes in temperature. The name "Frame Transfer" seems to suggest that this technology provides complete frames (485 active video lines) each transfer or integration period. This in not true in many cases. The Texas Instruments TC-245' has only a field of video capacity on the active image array and storage register, thus full frame resolution will always contain two fields that are separated by a 16.6ms time separation. If the active image array and storage register could hold the full 485 lines of a frame, then two fields integrated over an identical period of time can be imaged onto the sensor, stored, and readout. Imagers that have the capability to transfer two fields at a time into a full frame storage register are available, yet, significantly more expensive. Operation. As photons strike the silicon of the sensor pixels, a charge potential of electrons is accumulated in the pixel well. After 16.6ms (one field) of integration, a series of clocking pulses transfers the charge packets from the active register to the storage register (fig. 2). During the vertical interval the active array is used as a shift register, each row of charges moves vertically one line at a time from the active area into the storage register. Each line moves down sequentially until the entire field (242 lines of pixels) is contained in the storage register. The time required for this transfer is approximately 130^s (TC-245). When one image (field) is in the storage register, the next image (field) is being integrated onto the active array. The video information in the storage register is clocked to the horizontal readout register one line at a time, then moved out at the 14Mhz rate. The Texas Instruments Frame Transfer chip contains 242 pixels in the vertical direction. This is equivalent to one field. Providing full-frame resolution necessitates an interesting solution called pseudo-interlace. A proprietary technology called Virtual Phase was developed by Texas Instruments to increase the venicai resolution without adding more rows of pixels to the array. Each pixel is composed of a Clocked Well and a Virtual Well (fig. 3). A Virtual Barrier provides separation between each pixel well to prevent bleedover. The Antiblooming Gate provides a means to discharge excess electrons, thus reducing saturation and blooming. The wells are both equally sensitive to light. The purpose behind two wells per pixel is to provide a means to divide the pixel in-half. Changing the bias voltage to the active image array shifts the center (centroid) by one-half pixel vertically (fig. 4) during alternate fields, thus it is possible to increase the vertical resolution and decrease aliasing (loss of detail due to under sampling). A fifty percent overlap exists vertically between the two fields. The positioning of a line of pixels is such that for field 1, lines 1, 2, and 3 are adjacent. The pixels used for field 2, line 1 use 50% of the pixel from field 1, line 1, and 50% of the pixel from field I, line 2. This sequence repeats for the entire second field. Shuttering. Photons of illumination are normally allowed to integrate on the image sensor for 16.6ms before transfer to the storage register. Shuttering decreases the integration period to either 1/lOOOsec (1ms), or I/2000sec (SOOus). This feature provides a stop action effect for objects in the field of view that are in motion. Tlie shorter integration period also

Page 139

FRAME TRANSFER

1 f

SYNC

Cl£AR ARRAY PULSES r • 16.6 m» - J y-

^V-

^V-

SHUTTER TRANSFER PULSE

1

VIDEO OUIPUT r f

RGURE 5. SHUTTER TIMING

FRAME TRANSFER

TRIGGER PU12E

TRANSFER PUU5E

SBaOR INIECRATING STBtWE PBHOD

VIDEO OUTPVn

1

Jl

-^ e x t a m o i l o u r c o

•^'V yu intamoi to I

-\xV4 i n t t o 16.6 ms ( M o n o i a : 16 ms)

rJ PrevMMisiv ^ I ^ inTaoratea FIEID A

I

^' viviww viose intaofoteo bv nrees FIELDS

X • INTEGRATION PERIOD, ranges trom 4 ms t o 16.6 ms McRtmum tnaoering reD«ttnon rorto • 240 hz

RGURE 6. ASYNCHRONOUS RESET

1 '

Page 140

decreases sensitivity; four f-stops for 1ms, and five f-stops for 500fiS. Since each f-stop effectively cuts the electron accumulation in-half, shuttering may require additional illumination. Timing. .Achievmg an electronic shuttenng effect on the image sensor requires additional pulses. No mechanical device is used to stop light from reaching the sensor, thus a way must be provided to clear the sensor of undesired charge accumulation. This is accomplished with Clear Pulses (fig. 5). Two clear pulses in rapid succession initiate transfer of the image accumulated on the active array to the storage register. The first pulse shifts an undesirable image that has accumulated for the previous 15ms. The second pulse, a few microseconds later ensures the array is emptied of any residual accumulated charge. Then the sensor is allowed to integrate for the desired 1ms, or 500/iS period. A transfer pulse initiates the movement of the captured video image into the storage register for readout. Asychronous Reset^ (option). .Allows extemal control of the vertical interval by supplying a trigger pulse from another source to synchronize the camera to extemal events. Upon receipt of the trigger pulse (fig. 6); the vertical interval is initiated, and the previously accumulated charge on the active array will be transferred to the storage register within 200^s. This field of information will contain an image that integrated on the sensor immediately prior to receiving the trigger. The duration of integration on field A will be random (the trigger pulse can occur anytime during the vertical period), resulting in an unpredictable output. Thus, field A is not used. After the 200/xs period, the active array is now ready to integrate the desired image by strobing the subject. Integration on the array will continue until the next vertical sync pulse (16.6ms), dr next reset pulse, whichever occurs first. Then the cameras intemal transfer pulse will move the information to the storage register and begin readout. If the repetition rate of the trigger pulses is increased, the vertical pixel count will decrease. Examples: 60Hz = 242 vertical lines 120Hz =121 vertical lines 240Hz = 61 vertical Lines The readout from the storage register is limited to a fixed RS-170 rate, thus increasing the frequency of the trigger pulses will not allow sufficient time to read the entire field out of the storage register before the next image is clocked from the active array to the storage register. Advantages. Frame Transfer technology exhibits contiguous pixels (near 100% fill factor). Fill factor is the ratio of active image area to total image area on the surface of the sensor. Each pixel attaches to its neighbor vertically to facilitate the transfer process. Thin channel stops (barriers) separate each column of pixels to reduce bleed over. Large pixel size increases sensitivity. The spectral response ranges from 250nm (UV) with the faceplate removed, through the