Page 121
electrode and a positive potenual to the collection electrode (12c). The accumulated charge packet of holes will shift to the sense electrode where another read is penormed. The difference m the two potentials represents the voltage equivalent of the amount of light striking the pixel dunng the integrauon time. The user or image processing algorithm makes a decision: eitiier use this value and clear (12d) the pixel to prepare for a fresh integration period, cr resume collection on top of the previous charge (12a). Clearing a pixel is accomplished by supplying a positive potential to both electrodes forcing the holes into the substrate (12d). This unique feature provides tiie means to image very bright objects and dim areas within the same scene by reading tiie highlights before tiiey saturate and allowing additional integration time for dim areas. CID chip technology has deeper pixel wells than Frame or InterUne Transfer (typically 300,000 vs. 80,000 electrons, respectively), tiius providing wider dynamic range. The sensitivity of CID's is about half tiiat of Frame or Interiine devices. Advantages. Near 100% fill factor, the entire active image area is sensitive to light. No separate storage register is required. There are no opaque areas on the imager. The isolation of each individual pixel and lack of transfer/storage registers provides greater resistance to blooming and smearing. Since the user controls the readout, tiie following reads are possible: progressive, partial area, or individual pixels. This can increase the information output rate if less than a full frame is desired. The fewer lines of readout desired Uie faster the update rate (non RS-170). Asynchronous reset provides capture of fast events by operating the camera in the Charge Inject mode (not allowing a charge to build on tiie pixels). Switching to "collect" upon receipt of an input control pulse starts integration time. Objects entering the field of view randomly can be captured in the center of the frame. The extemal trigger can activate a strobe and/or transition the camera into collect mode. CIDTEC 2710 RS-170. Sensor Picmre Elements: 776H x 512V Active Picmre Elements: 755H x 484V Pixel size: 12.0Mm x 12.7Mm Format: 2/3" Typical CID Camera Cost: S2,900 IMAGE FORMAT The size of the sensor's active imaging area is defined as image format. The most widely available and economic sensors are 2/3", 1/2". and 1/3" RS-170 devices. CCTV sensors have an aspect ratio of 4 x 3, meaning that the ratio of honzontal width to vertical height is four to three, respectively. Sensor engineering, manufactunng, and quality continuously improve. The smaller format imagers are fast becoming the norm. Smaller size allows hieher vieids and lower
Page 122
COMBINATION OF CAMERA AND MONITOR GAMMA = 1.0
3 a. O O
CAMERA GAMMA = 0.45
Ul a > u. O b o
PICTURE TUBE QAMMAES2,2
> i
SENSOR FACEPLATE ILLUMINATION
FIGURE 13. GAMMA CORRECTION
Page 123
cost. Recent camera entries into the market with 1/2" ana 1/3" imagers present equal resoiution and comparable sensitivity at less cost. One might think that sensiiivity must be lower due to the smaller pixel size. While it is true that less area means fewer photons, sensor manufacturers have compensated by adding additional gain on the sensor chip and incorporaung micro-lens technology. \Vhen replacing existing cameras or seeking new solutions it is very likely that a smaller format sensor will be selected due to availability and pnce. Changing from a larger format to smaller and maintaining the same optics have the effect of magnifying the image. The image format approach to identifying the size of the active image area began with tubes. The diameter was chosen as the specific identification criteria, typical tubes have diameters of 1", or 2/3". This designation was carried forward and applied to sensor chips. The following dimensions represent the aspect ratio of the three most common RS-170 image sensors: 2/3" sensor 6.6mm(V) x 8.8mm(H) x 11mm Diagonal 1/2" sensor 4.8mm(V) x 6.4mm(H) x 8mm Diagonal 1/3" sensor 3.6mm(V) x 4.8mm(H) x 6mm Diagonal MECHANICAL INTERFACE Standard CCTV cameras are equipped with C-Mounts (specific thread and pitch) for attachment of CCTV lenses. Lenses are available from a variety of manufacturers with the thread type defined as C-Mount. Microscopes with trinocular pons also have C adapters. Recentiy, CS-mount lenses have been introduced in tandem with camera manufacturers' new 1/2" and 1/3" fonnat sensors. The difference between C and CS is the back focal distance. Back Focal is the distance between the center of the rear lens element and the sensor image plane. C lenses require a back focal length of 17.5mm; CS lenses only require 12.5mm, meaning that the CS type lens is mounted closer to the image array. This allows for using smaller and fewer optical elements, which in tum results in smaller mechanical size and lower cost. Optically the quality of better CS lenses is equal to C lenses. .Apenures are proportionally smaller and the lens uses fewer elements. Light transmission is equal to. or better than C type. CTAMMA
Gamma correction is a result of non-linear phosphor coating on picture tubes. Picture tubes consistentiy compress black signals and stretch whites. Gamma defines the slope of the curve representing the difference between linear input and actual output. The sensor is a linear output device. If the camera is viewing a scene that changes linearly from left to right (with left representing black and right representing white), the display of this information on the monitor will appear as a slope of a curve that is shallow in the dark region and steep in the white areas (figure 13). For a given increase in illumination, a corresponding linear increase in millivolts is generated at the output of the sensor. The picture tube (monitor) will not accurately represent this information. During the infancy (1950's) of television it was decided to incorporate gamma correction into the camera since at that time far fewer cameras existed than monitors. Today gamma correction still resides in the camera.
Page 124
/ ILUIMIfMTION INPUT
FIGURE 14. LOGARITHMIC RESPONSE HUMAN EYE
El
HIGH CONTRAST rAflOET
BRIGHTNESS MEASUREMEffT f
1 PEBCOVEO aniOHTNESS
FIGURE 15. HUMAN EYE EDGE DETECTION
Page 125
When desiring to view the output of a camera directiy on a monitor, a gamma of 0.45 is selectea. This will stretch the black and compress the whites. Since monitor picture tubes have a gamma factor of approximately 2.2. applying the camera conecuon of 0.45 yields a linear rauo (2.2 x 0.45 = 1). Measurement applications, inputs to frame grabbers, and image processing require the camera be operated in a gamma of I.O, providing a linear ourput. HUMAN EYE RESPONSE The response of the human eye to illumination is also not linear. It is actually a logarithmic response, where the steepness of the curve is greatest in the darker regions (figure 14). The curve flattens out in the white region. This makes incremental changes of the same magnitude easy to identify in the black area and difficult in the white region. By darkening images, we increase our ability to discem contrast changes. Another anomaly of the human visual system is the apparent sharpening of edges. An edge enhancement mechanism is built into our human imaging system. Viewing black and white rectangles placed horizontally in a row, the white areas appear to be whiter just prior to the transition to black (figure 15). Equally, it would appear as if the black areas become a little blacker just before transition to white. Camera circuits can be altered to provide a similar sharpening of edges. Most cameras include a filtering operation to smooth pixel-to-pixel transitions. Changing the filter's parameters creates sharpness at the expense of adding ringing (Oscillations). RFiiQLUTION The ability of a sensor to reproduce the detail of a viewed image is called resolution. Venicai line resolution is 485 for a 525-line raster. This is the total number of active video lines. When reading the image on a monitor using the EIA test chan or another wedge pattem. histoncal experimental research has lead to a kell factor of 0.7 times the active lines equal to vertical resolution on the monitor. Thus vertical resolution displayed on a monitor is 350TVL (485 x 0.7) for RS-170 525-line systems. A limitation to reproducing an image spatially is stated as the Nyquist Sampling Theory. To clearly resolve a given frequency, the sample rate must be a minimum of two times the frequency being sampled. Aliasing occurs if the sample rate is less than twice the original signal frequency to be imaged. Modulation Transfer Function. Modulation transfer funcuon represents the contrast between black and white information at differing resolutions. \Vhen the camera is viewing a black and white target with a converging wedge pattem. the lower resolution detail will be presented as having a much higher modulation (figure 16). Higher resolution details appear as only slight changes in gray level at the limiting resolution of the sensor. Camera circuit rise time and bandwidth limitauon create this condition.
Page 126
570 H TVL OF RESOLUTION
700 mV -
•
OUTPUT AMPLITUDE
50 mV
H TVL OF RESOLUTION
FIGURE 16. MODULATION TRANSFER FUNCTION (MTF)
Page 127
Honzontal Resoiution. Horizontal resolution is the number of black and white lines that are discernible across a video line equal to the height of the raster. Each line is counted, as opposed to line pairs which are used in photography and image mtensiilers. To find pixel resoiution: Number of Pixels x 3H = Resolution per picture heiaht 4W To find line pairs per millimeter: Lp/mm =
HTVL 2 x _4. x _ 1 _ 3 PW
H= height W= Width HTVL= honzontal TV lines PW= picture Width
Resolution can also be directiy read off a monitor when the camera is focused onto an EIA resolution test pattem. Attention needs to be paid to the variables associated with the system to ensure the result is not limited by anotiier system component (e.g., monitor, lens). The greater the horizontal detail or number of pixels, the faster the clock speed required if RS-170timingis maintained and higher resolution is desired. The total number of horizontal pixels clocked out during the active video time (52MS) for a 768-element sensor equates to a pixel clock frequency of 14Mhz. 52us = 67ns/pixel 768 Pixels i 67ns
= l4Mhz
Higher resolution cameras (1134 H-pixels) operating at the RS-170 line rate increase the pixel clock frequency: 52us = 45.8ns/pixel 1134 Pixels
1
= 21 Mhz 45.8ns
ANALOG TO DIGITAL An RS-170 signal input to an A-D convener is sampled or chopped into segments, each one representing a specific locauon on the onginal sensor array. .A phase locked loop is used by the frame grabbing device to arrive at a close approximation of pixel spatial location. Some pixel jitter or uncertainty is inherent m this process. Using the camera pixel clock achieves a better result. Each sample or pixel is given a brightness value based on the
Page 128
number of bits, where 8-bit depth equals 256 shades of gray. The Nyquist sampling theorem again applies. To fuily represent the rate of brightness change in the original image we must sample at a rate at least two umes the highest spatial frequency. This ensures a re-creation of the detail. Aliasing is the erroneous representation of high frequency informauon from the original image, .\liasing occurs when scene details have a spatial frequency greater than half the sampling frequency. If under sampling is happening, tiie result is transference of the high frequency information to a lower frequency wnich appears as a moire pattem. APPLICATIONS OF VIDEO CAMERAS Laser Profiling, Interferometry, Tracking, Medical, Scientific, Inspection, Microscopy, Semiconductor processing. FUTURE POSSIBILITIES FOR VIDEO CAMERAS Active Pixel Sensors, down-scaling format, image processing in the camera, alternative formats, HDTV, Digital output, camera on a chip.
Page 129
Bibliography Baxes. Gregory, Introduction to Image Processing. Cascaae. 1984. Bower Frank. CCD's: How to Use Them. Photonics Design and applications Handbook 1988. Fields, Roben and M. Bonner Denton. .Array Detectors Expand Atomic Spectroscopv. Laser Focus World. March 1992: 107-113. Fossum. Eric. Active-Pixel Sensors Challenge CCDs. Laser Focus World, June 1993. High-Technologv Television. Visual Information Institute. Xenia, Ohio. McGiniy, Gerald, Video Cameras: Theory and Servicing, .Matsushita, 1984, Thorpe. Larry. Designers Straggle with S/N. TV Technology, Feb 1988. Thorpe. Laurence and Duane Dahlberg. On-chip Lens HvperHad Sensors for Increased CCD Sensitivity. Advanced Imaging, June 1991: 43-45.
Page 130
SECURITY i-
Riding Atlanta's Rails in Safety SUMMARY: Atlanta's commuter rails use video surveillance to help with customer service. By Andy Maslowski • RIDERS OF THE MARTA rail transit network in Atlanta have at least one extra level ot' safety, ihanks to a surveillance camera system installed at its stations. "Back in the mid-1970s, in the original Jesien concept, it was decided that a cam•jra SNsiem would be installed in the rail :ransit svviem.' recalls .VIARTA police Jtiiei Gene VVilson. Since then, the Metropolitan .Atlanta Rapid Transit Authority has put in more than 360 surveillance cameras, adding them as new stations are brought on line. "On occasion, the cameras will help us •vith cnme problems, but their pnmary t'unclion is as an aid to customer service." he says. Cameras have been placed inside the paid areas ot the stations, ot'ferinc esseniially full coverage. Each rail station has between 12 and 14 cameras, and these are monitored trom one ot five "zone centers," Each zone center has about 95 monilors, and the operator who runs the cameras can start recording whenever he sees something unusual, or if he gets a request 10 do so from a help phone," a handicap door access, a fare gate, or any other locauon he's alerted to. Service is Our Business The main ausunuize oi ihc camera ^v^lem is 16/6MV customer service. As Wilson explains. •'Many times it has proven itself helpful in controlling crowds on a waiting platform, if we see a potential problem building, we'll send a transit police officer to the spot. Once there, the officer will make sure the people don't get too close to the rail or the tracks." Police otficers and emergency crews are dispatched to a scene because of the cameras. In some cases, the cameras spot
The M.\RT.\ has put in more tiian itiO \io\ciiianLC ( anicras.
workers who need help. But the cameras also serve as an effective deterrent to crime. This is true for serious crimes as well as for catching those who try to avoid paying their tokens at the fare gate. The M.ARTA police force includes -ome 220 sworn officers, and this must aliO be factorea in as a meaningful crime deterrent tor the rail system. The Best Equipment For the Job The MART,A cameras are not recording ail the time, but if the camera operators at the zone centers see something unusual, they hit the record button immediately. "We've looked at putting in an enhanced system, one that records continuously, but 1 don't know If we'll ever do that,' \Vilson says. During the past decade, the MARTA system has relied heavily on surveillance equipment from Cohu's Electronics Division. The first cameras installed in 1985 \'.ere 5100 series tube models, including both fixed and zoom lenses. In 1990, more stations were added, so newer 4800 series cameras were added. According to Laura Sallee. a Cohu applications engineer, the Cohu 5100 senes is the predecessor ot the 4800 senes CCD cameras. The 4«()() senes is ideal for applications that reauire botn niszh resolution anu hich sensiiiv-i