Page 11

The chart below shows all of the icons for CodeViewer™ software and their definitions.

Icon

Description

Power Icons 50% to 100% capacity of battery 20% to 50% capacity of battery 0% to 20% capacity of battery – recharge battery as soon as possible Battery is recharging No icon is displayed when battery blank is used with a cabled reader Connection Icon Reader is connected physically or wirelessly to a receiving device (computer, handheld, etc.) Note: Some RS232 configurations can not be detected No icon is displayed when the reader does not detect a connection Communication Mode Icons RS232 communication mode enabled PS/2 communication mode enabled USB communication mode enabled Bluetooth communication mode enabled Packet Mode Icons Standard Bluetooth Reliability Mode (previously One Way Mode) – no acknowledgement required Additional Bluetooth Reliability Mode (previously Two Way Mode) – packetizedcommunication between a CR3500 and an application USB Downloader mode Keyboard mode – can be used as either USB keyboard or PS/2 keyboard input mode Virtual COM Port One Way mode Secure mode – data encryption mode enabled Memory Icons No stored data Some stored data Memory is at least 90% full No batch mode – data will not be stored in the reader’s memory if not connected Input Mode Icons Caps Lock – data entered manually on the keypad will be in capital letters Lower Case – data entered manually on the keypad will be in lower case letters Numeric – data entered manually on the keypad will be numeric Symbol – data entered manually on the keypad will be symbols Locked – buttons pushed on the reader’s keypad will be ignored* *Note: To lock/unlock reader buttons press Shift + Up Arrow simultaneously.

Save Settings

C004387_07_CR3500_ User_Manual - 5

Page 12

1.7 - Batch Operation 1.7.1 - Introduction The CR3500 features a batch mode for applications requiring a portable reader. Batch mode allows a user to store scanned data to the reader’s non-volatile memory. The user may transfer the data to a host computer when needed. To utilize batch functionality you will need to a battery cartridge or battery handle. The CR3500may be programmed to operate in three different batch modes: 1.

Send & Buffer Mode (Default) - In Send and Buffer Mode, the CR3500 will automatically detect when the USB or RS232 cable is detached, or the Bluetooth® radio is out of range, and will switch into batch mode and buffer the data in non-volatile memory. When the reader is reconnected to your host computer, or when the Bluetooth Radio is back in range, the reader will auto transfer the buffered data. Once transferred, the data is automatically erased from the reader’s memory. Note: Once a unit is reattached to a cable, or enters within radio range, any data scanned WILL NOT be saved to the non-volatile memory. For RS232, a power supply connection is used to detect when a reader is attached to a host computer.

2.

Log Only Mode - In Log Only Mode, the reader will only store data into non-volatile memory. You can only retrieve the data by scanning the Transfer All Stored Data in Memory code (see explanation next page). Once the reader’s memory has been transferred to a host computer, all of the data will still reside in memory. A user must scan the Delete Scanned Data from Memory code to clear memory.

3.

Send & Log Mode - In Send and Log Mode the reader will save a copy in non-volatile memory as well as send the data if the reader is connected. The data can be retrieved by scanning the Transfer All Stored Data in Memory code or the Transfer Only Unsent Data in Memory code (see explanations next page). Once the reader’s memory has been transferred to a host computer, all of the data will still reside in memory. A user must scan the Delete Scanned Data from Memory code to clear memory.

Note: The reader can be defined as connected if:

1)

2)

3)

4)

The Bluetooth radio is in range; The USB cable is attached to a host and the reader is enumerated; The reader is in RS232 Cabled - No Power mode; or The RS232 cable is attached to host with power supply and the reader is in RS232 Batch-Cable Detect (Default) mode.

The CR3500’s dedicated batch memory is a minimum of 1MB. To determine the number of reads that may be stored, divide the average bytes of a scan into the total minimum memory. Feedback After a successful decode in batch mode, the unit will beep once and the memory LED will flash either red or amber depending on memory level, and every 15 seconds the battery LED will flash green, amber or red depending on the battery level. This feedback behavior is accurate when a reader is cabled or uncabled. Save Settings

C004387_07_CR3500_User_Manual - 6

Page 13

Transferring and Deleting Data There are three different codes to transfer and delete data in memory. 1.

Transfer All Data in Memory - This code will send all data in memory everytime the code is scanned.

2.

Transfer Only Unsent Data in Memory - This code will send only the data in memory that hasn’t already been sent when the code is scanned (ONLY works in Send & Buffer and Send & Log modes).

3.

Delete Scanned Data from Memory - Scanning this code will erase all data in the reader’s non-volatile memory.

Auto Transfer Buffer Memory By default, when reconnected, the CR3500 will automatically transfer any data in memory once a connection to a host is established. If your application is not ready, the reader will send the data anyway and the data could be lost. If you do not wish for the reader to immediately send data upon connection, please scan the Disable Auto Transfer Buffer Memory code. Send & Buffer Mode (Default)

Log Only Mode

Transfer All Data in Memory

Transfer Only Unsent Data in Memory

Enable Auto Transfer Buffer Memory (Default)

Disable Auto Transfer Buffer Memory

Send & Log Mode

Delete Scanned Data From Memory

RS232 Considerations In RS-233 Cabled-No Power mode, the CR3500 will behave as if it is always connected even though the serial cable is disconnected or the power adapter is unplugged. Data scanned will be sent, regardless of connection status. Data scanned in Cabled-No Power mode will be lost if the CR3500 is not connected to the serial cable - it will not buffer the data, unless Send & Log or Log Only mode has been enabled. In RS232 Batch-Cable Detect (Default) mode, the CR3500 will detect if it is connected to a powered serial cable, if it is, it will then send the data. If a powered serial cable is not connected or if the power adapter is not connected to the serial cable, the CR3500 will buffer the data. When the CR3500 is then connected to a powered serial cable, the data will automatically upload. RS232 Batch-Cable Detect (Default)

Save Settings

RS232 Cabled-No Power

C004387_07_CR3500_ User_Manual - 7

Page 14

1.8 - Cabled Operation 1.8.1- Introduction The CR3500 is a Multi-Interface Unit (MIU) and is available with USB and RS232 cables. All of the cables are connected to the CR3500 with a 8-pin DIN connector (Figure 1.8).

Figure 1.8

Hand Held CR3500 - To install a cable directly to the CR3500, correctly line up the 8-pin DIN connector into the back end of the reader. The arrows on the connector should be facing down (Figure 1.9). When the reader and the cable connector are lined up, firmly push the cable into the reader. The cable has a locking mechanism that will firmly hold the cable in place (Figure 1.10). To dettach the cable from the reader, you must pinch the plastic on the 8-pin DIN and pull back to disengage the connector.

Figure 1.9

Figure 1.10

CR3500 with Cabled Handle - If a handle was purchased for use with the CR3500, the 8-pin DIN connector is at the bottom of the handle (Figure 1.11). Insert the 8-pin connector and firmly push the cable into the handle. The cable has a locking mechanism that will firmly hold the cable in place. If using the H2 cabled handle, for additional stability, there is an optional cable attachement clip that can secure the cable to the handle with two threaded screws (Figure 1.12).

Figure 1.11

Save Settings

Figure 1.12

C004387_07_CR3500_User_Manual - 8

Page 15

1.8.2 - CR3500 as a USB Keyboard To connect the CR3500 to your host computer via USB interface: 1.

Attach the USB cable to CR3500 (Figure 1.13).

2.

There is no need to power of the computer (Figure 1.14) Connect the USB cable to a USB port on the computer (Figure 1.15).

3.

Once properly connected, the CR3500 will power on and beep.

4.

Scan the below code (M049_03) for USB Keyboard Mode:

USB Keyboard Factory Reset

7.

Save Settings

Scan the Save Settings Code (M188_02)

Figure 1.13

Figure 1.14

Figure 1.15

1.8.2.1 - Addional USB Communication Settings USB Keyboard Mode - Data is sent from the Reader and interpreted by the host just as if a US keyboard was being used to enter data. USB Downloader - This mode is used when downloading firmware. USB Native Two Way Mode - This mode is utilized when there is a need for error-corrected communication between the CR3500 and an application through the USB port. USB Virtual COM 1 Way Mode - This mode allows a USB-cabled CR3500 to function as a virtual COM port. To use the CR3500 in this mode, download the driver at www.codecorp.com/downloads.php. USB HID POS (Terminal ID 131) - This mode allows a USB-cabled CR3500 to communicate as a USB HID POS (Terminal ID 131) device.

Save Settings

C004387_07_CR3500_ User_Manual - 9

Page 16

1.8.2.1 - Addional USB Communication Settings (continued) Scan the following codes to set the appropriate USB communication setting: USB Keyboard

USB Downloader

USB Native Two Way Mode

USB Virtual COM 1 Way Mode

USB HID POS (Terminal ID 131)

1.8.2.2 - Keyboard Support Scan the following codes to set appropriate keyboard mapping: US English (Default) No Leading 0 for non-printable characters

French

German

Custom Keyboard

US English - Leading 0 for non-printable characters

Japanese

Alternative OS (Windows CE/MAC/Unix/Linux) Enable

US English - ctrl + char for non-printable characters

Universal Keyboard

Alternative OS Disable

Requests map to be installed

Save Settings

C004387_07_CR3500_User_Manual - 10

Page 17

1.8.3 - PS/2 Cable Installation Guide 1.

Power off the computer. If you disconnect the computer’s keyboard while it is powered on, your computer will lock up.

2.

Attach the the PS/2 cable to the CR3500.

3.

If you have a cabled keyboard, detach the keyboard cable from the computer and connect that same connector to the female connection on the CR3500 PS/2 cable (Figure 1.16).

4.

Now connect the male CR3500 PS/2 connector into the keyboard port on the computer (Figure 1.17).

5. Power on the computer. The CR3500 is powered by the PS/2 port and does not require a power supply. 6. Once properly connected, the CR3500 will power on and beep.

Figure 1.16

PS/2 Factory Reset

Figure 1.17

Save Settings Code does not guarantee compatibility with all models of computers.

Save Settings

C004387_07_CR3500_ User_Manual - 11

Page 18

1.8.4 - RS232 (Serial) Cable Installation Guide 1.

Attach the RS232 (Serial) Cable to the CR3500.

2.

Connect the RS232 (Serial) cable to a serial port on the computer (Figure 1.18). There is no need to power off the computer.

3.

The RS232 (Serial) interface has an optional 5V/1.5A power supply (Figure 1.19). If you have a power supply, plug the power supply adapter into the RS232 (Serial) cable and then plug the power adapter into a wall socket (Figure 1.20).

Figure 1.18

Figure 1.19

Figure 1.20

4.

Once properly connected, the CR3500 will power on and beep.

5.

For RS232 (Serial) mode scan M418_02 (below). If the power supply is not connected scan M074_02 (below).

6. Scan the Save Settings Code (M188_02). RS232 (Serial) Factory Reset

RS232 (Serial) Mode No Power Supply Save Settings

RS232 (Serial) Factory Default Settings Mode: RS232 (Serial) One Way Mode Baud Rate: 57600 Stop Bits: 2 Data Bits: 8 Parity: None

Warning: Code Corporation approved power adapter must be used. Reader failure due to use of incorrect power adapter will void warranties.

Save Settings

C004387_07_CR3500_User_Manual - 12

Page 19

1.8.4.1 - Additional RS232 Communication Data Bit Settings Scan the following codes to set the appropriate data bit: 7 Data Bits

8 Data Bits (Default)

1.8.4.2 - Additional RS232 Communication Baud Rate Settings Scan the following codes to set the appropriate baud rate: 1200

2400

4800

9600

19200

38400

57600 (Default)

115200

1.8.4.3 - Additional RS232 Communication Parity Settings Scan the following codes to set parity: Even

Save Settings

Odd

None (Default)

C004387_07_CR3500_ User_Manual - 13

Page 20

1.9 - Bluetooth Radio Operation 1.9.1 - Introduction The CR3500 features a Bluetooth® wireless radio. The radio allows for point-to-point wireless communication with other Bluetooth devices that support serial port protocol (SPP). If keyboard entry is necessary, CodeXML® Router will need to be installed. The following guide will give you general instructions on connecting your CR3500 to a desktop or laptop computer with a Bluetooth radio. Connecting With A QuickConnect Code The easiest way to connect to a Bluetooth device is to visit the Code website and create a QuickConnect Code that is specific to your device (Figure 1.21). This code will link your CR3500 directly to the desired Bluetooth device. To create a QuickConnect Code, you will need to know the Bluetooth address (often referred to as the BD_ADDR) of that device. You can usually find the 12-character Bluetooth address somewhere on the device near the device’s serial number (see Figure 1.22).

Figure 1.21

Figure 1.22

If you purchased a CodeXML® Bluetooth Modem or a Belkin® Bluetooth adapter from Code or from an authorized distributor, a QuickConnect Code was included. If you bought a Bluetooth adapter separately and wish to create a QuickConnect Code, please visit Code’s web site at: http://www.codecorp.com/bdaddr.php. Important Note: You will need to locate the Communications (COM) Port assigned to the Bluetooth serial port protocol. While installing the Bluetooth Configuration Manager Software that was included with your Bluetooth adapter, make sure to note the Communications (COM) Port number the software assigned for the adapter (e.g., COM 10). This is the COM Port through which the CR3500 will connect. To connect your reader, use the following steps: 1. Power on the CR3500 reader by pressing one of the red buttons for one second to power on the reader. 2. Scan the Reset to RF Factory Defaults Code (M684_01). 3. Scan the Quick Connect Code you receieved or created from Code’s website. 4. The CR3500 will automatically connect to the computer. By default, the CR3500 will beep once after it connects and beep four times in a row if it did not connect. 5. Scan the Save Settings Code (M188_02) if you want to save the wireless connection settings to the CR3500 so that the CR3500 will automatically try to connect wirelessly the next time it is powered on. Reset to RF Factory Defaults

Save Settings

Example: QuickConnect

Save Settings

C004387_07_CR3500_User_Manual - 14