For the Code CR2500

Page 46

Chapter 4 - Reader Feedback and Special Settings

Save Settings

C004386_07_CR2500_User_Manual -

40

Page 47

4.1 - LED Feedback The CR2500 features two (2) LEDs on the front of the reader. These LEDs give feedback based on various funcitons of the CR2500. Each LED has a small icon just underneath it that represents the following:

Memory / Connection Icon Battery or Power Icon

The CR2500 will automatically flash battery or power status every 15 seconds. Each LED can show three (3) colors; Green, Amber, or Red. The colors will vary depending on the message the unit is sending. •

Green = 50% - 100% capacity of battery

•

Amber = 20% - 50% capacity of battery or 10% - 99% of memory available

•

Red = 0% - 20% capacity of battery or no memory available

The CR2500 also emits beeps or vibrates for user feedback. Please follow the table below to better understand the CR2500’s feedback.

Normal Operation Feedback Memory/Connection LED

Battery LED

Sound

CR2500 Successfully Powers Up

Flash Green

Flash Green

CR2500 Successfully Enumerates with Host via USB Cable

None

Solid Green

1 Beep

Attempting to Decode

None

Battery Status

None

Save Settings

1 Beep

C004386_07_CR2500_ User_Manual

-

41

Page 48

Normal Operation Feedback (con’t) Memory/Connection LED

Battery LED

Sound

Successful Decode and Data Transfer via cable

None

Solid Green

1 Beep

Successful Decode and Data Store

Memory Status

None

1 Beep

Batch Mode memory full

Solid Red

None

3 Beeps

Configuration Code Successfully Decoded and Processed

None

None

1 Beep slight pause then 1 Beep

Configuration Code Successfully Decoded But Was Not Successfully Processed

None

None

6 Beeps

Bluetooth Radio Feedback Memory/Connection LED

Battery LED

Sound

Attempting to Connect

Flashes Blue

Solid Green

Failed to Connect

None

None

Flashes Blue Every 15 seconds

Flash Battery Status Every 15 seconds

None

Flashes Blue

None

None

Connected

Sending Data

Save Settings

1 Beep if successful 4 Beeps if not successful

4 Beeps

C004386_07_CR2500_User_Manual -

42

Page 49

4.2 - Volume and Vibration Settings Scan the following codes to set vibration mode: Vibrate On / Beep On

Vibrate On / Beep Off

Vibrate Off / Beep On

Scan the following codes to set your reader’s volume: Beep Off

Beep Low

Beep High (Default)

4.3 - Code Readability Index The Readability Index provides a measurement of a specific symbol’s ease or difficulty to be decoded by the CR2500. The Readability Index is specific to the CR2500, and should not be confused with a verification quality measurement. The Readability Index is a blend of information obtained from the internal operations of the decoding algorithm pertaining to contrast, symbology construct, error detection, forward error correction (if applicable), and other symbology-specific characteristics. The Readability Index is a score on a scale of 01 (very poor) to 100 (very readable). Due to differences based on motion, skew, reflection, focus, and ambient lighting, the Readability Index on the same symbol may vary somewhat from read to read. However, a poor contrast or damaged symbol will score lower than a high contrast undamaged symbol. The Readability Index can be used as a quick check on the reliability of label generation or marking systems. When used in conjunction with the CR2500 stand (or fixed mount positioning) which fixes the distance from the reader to the symbol, and constant ambient light, the Readability Index provides a symbol quality assurance tool and check point for feedback to an overall label or marking quality control system. The Readability Index is enabled by first reading a CodeXML® rule into the permanent CR2500 Memory: Code Readability Index Rule:

Readability Index Output Enable:

Readability Index Output Disable:

Each time a data symbol is read, the index will be output, followed by a comma, (,) followed by the decoded data. The reader will store the rule and reset, but will not output the Readability Index until the Readability Index Output Enable code is read. The Reader will continue to output the Readability Index upon every read until disabled, either by reset or by reading the Readability Index Output Disable code.

Save Settings

C004386_07_CR2500_ User_Manual

-

43

Page 50

4.4 - Backlight Intensity Settings Scan the following codes to set the intensity of the CR2500’s backlight with High being the brightest and Low being the dimmest: Low Med - Default High

4.5 - Backlight Timeout Settings Scan the following codes to set the backlight settings: Backlight Off

3 seconds (Default)

6 seconds

10 seconds

4.6 - Targeting Settings Scan the following codes to turn targeting on/off: On (Default)

Off

4.7 - Reader Power Off Settings Scan the following codes to set the amount of time before a reader powers off: 1 Hour

Save Settings

2 Hours - Default

4 Hours

C004386_07_CR2500_User_Manual -

44

Page 51

4.8 - Reader ID and Firmware Version To find out the Reader ID and firmware version, open a text editor program (i.e., Notepad, Microsoft Word, etc.) and read the following code: Reader ID and Firmware

You will see a text string indicating your firmware version and CR2500 ID number (see below):

Xap/iVVVVWWWWXXXXSSSSSSSSSSPXX-XX+XXX

Xap/i - Code Internal ID (not applicable) VVVV is the application firmware version number WWWW is the bootloader firmware version number XXXX is the radio firmware version number SSSSSSSSSS Reader’s serial number (ten digits) P is “A” if running firmware is the application, “B” if BootLoader XXX-XX+XX - Internal ID (not applicable) Example: Xap/i3000300006040010002363A06D-SD+SQ Note: Code will periodically release new firmware for CR2500 readers. For information on latest firmware versions, call Code at (801) 495-2200. To upgrade firmware, please visit our website at http://www.codecorp.com/codesupport.php and follow instructions provided.

4.9 - Reader Settings Lock To lock or unlock the current settings on your reader please scan the codes below: Reader Settings Locked

Reader Settings Unlocked

NOTE: Prefix and Suffix programming codes, memory transfer and delete commands, “Clear All CodeXML® Rules” and “Suffix -Erase/None” commands are not locked by this feature.

4.10 - Lock-out Link Mode This mode can be used to establish a permanent connection between the reader and a CodeXML® modem. Prepare the reader to communicate in ‘RF Comm Mode’ by scanning the QuickConnect code on the paired modem to which you wish to establish a permanent link. Listen for the single beep to verify the connection acknowledgement. Scan the Lockout Link Mode code (see below). Set appropriate timeout settings, if applicable (see Section 1.4.4). To reassign a permanent connection to a different reader, scan the unlock link code. Using the ‘new’ reader’ follow the directions outlined in the previous paragraph. Lockout Link Mode

Save Settings

Unlock Link Mode

C004386_07_CR2500_ User_Manual

-

45

Page 52

Chapter 5 - Advanced Decode Performance

Save Settings

C004386_07_CR2500_User_Manual -

46

Page 53

5.1 - Set Targeting Zone Tolerances The targeting tolerance is the zone around the green LED which is eligible for decoding. The values of each of the following codes are the percent tolerance based on the size of the barcode. As the targeting tolerance becomes smaller the targeting green LED must be more centered in the symbol being read. Conversely, as the targeting tolerance gets larger there is less precision needed with the green LED. If there is more than one decodable code in the field of the, the symbol closest to the targeting green LED will be decoded.

200 400

Save Settings

1600 (Default) Least Accurate

C004386_07_CR2500_ User_Manual

-

47

Page 54

5.2 - Windowing If only one size of bar code is being scanned in an application, the CR2500 can be optimized to reduce processing time by adjusting the viewing area within the field of view of the image. By reducing the vertical window value of the imager to 200 pixels, 1-D codes are processed more quickly. Because only a horizontal strip of a 1-D code is needed to be decoded, using a narrow strip of the imager is all that is needed. The area above and below the 200 pixels, which is always in the center of the imager, is ignored. This approach reduces the number of pixels that must be processed. Windowing can improve the processing time of 1D and 2D codes. You may negatively impact reader performance if the window size is too small. If it is necessary to have the reader farther away than normal to read the code, the window may be too small. Reading other types of codes, especially large codes, may be difficult while using this setting.

SAMPLE

SAMPLE

Medium Code Windowing

Save Settings

SAMPLE

Small Code Windowing

C004386_07_CR2500_User_Manual -

48