The text of a manual · part 4 of 7
Code Reader 2500 User Manual, pages 28 to 36
Pages 28 to 36 of 62
The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Code CR2500
Page 28
1.8.10 - Installing CodeXML® Router Bluetooth Edition for Windows 1.
Insert the CodeXML® Router Bluetooth Edition for Windows CD into your PC’s CD drive. The CD will automatically begin the installation process. When you get to the screen pictured below, please enter the CD Serial # Key found on the card included in the CD case.
2.
When you get to the screen pictured below, please choose from the appropriate settings. For a description of each setting, please see Chapter 3. If connecting via Bluetooth radio, you will need to know the Virtual COM port number your Bluetooth software has assigned (see Frequently Asked Questions). If you wish to enable the AutoDownload feature please check the appropriate box in the next screen. Finish the installation process and restart your computer.
3.
After restarting your computer, you will see a blue “arrows” icon in the system tray of your computer. CodeXML® Router was successfully installed.
Save Settings
C004386_07_CR2500_User_Manual -
22
Page 29
1.9 - Targeting and Reading Techniques The CR2500 utilizes digital camera technology to take a picture of a symbol. Once an image is captured, the CR2500 utilizes advanced decoding algorithms to extract data from the captured image. The CR2500 is available as a palm-held reader or users may purchase a handle (available in various types). The palm held reader features left and right triggers. These triggers may be programmed to perform various features. The reader is shipped with the left trigger and right trigger functioning as a decode symbol command. Each handle has a trigger on the grip. The two triggers on the top of the reader also work when the handle is attached Figure 1.24). trigger handle trigger
Figure 1.24
To read a bar code with the CR2500: 1.
The CR2500 features omnidirectional decoding. Center the symbol in any orientation within the targeting line pattern (figure 1.25).
Figure 1.25
Note: The CR2500 can read a bar code that is not centered or aligned; however, the CR2500 performs best when a code is aligned. If two (2) bar codes are within the imagers decode zone, the CR2500 will decode the symbol closest to the center of the targeting line. 2.
The CR2500 was developed to decode both very small 2-dimensional symbols and larger 1-dimensional symbols. The reader has an innovative dual field decode zone. The CR2500 DECODES ONLY THE WIDE FIELD BY DEFAULT. By default, the reader will focus on wide field for larger codes (optimal focal point 3.3 inches). The reader can be programmed to focus on high density for smaller codes (optimal focal point is 3.3 inches).
3.
Hold the CR2500 still - DO NOT SWIPE OR MOVE THE READER. Press the trigger until the CR2500 beeps, indicating the code has been successfully decoded.
4.
The reader may be optimized to your specific environment by scanning codes in Chapter 2.
Save Settings
C004386_07_CR2500_ User_Manual
-
23
Page 30
1.10 - Imager Field Selection and Resolution The CR2500’s dual field optical system may be modified based on your scanning environment. The 1.3 Million Pixel imager is divided into wide field and high density decode zones. In each zone the resolution is 1024 x 640 pixels (see Figure 1.26). If only the high density field is used (small symbols), the wide field image can be ignored. If only the wide field is used (large symbols), the high density field can be ignored. Further optimization may be obtained by "windowing" the field to a smaller area. BY DEFAULT, THE CR2500 DECODES ONLY THE WIDE FIELD. 1024
Wide
640
High
640
Density
Figure 1.26
SXGA Imaging Area
1.11 - Decode Zone
Figure 1.27 Save Settings
C004386_07_CR2500_User_Manual -
24
Page 31
Chapter 2 - Optimization and Trigger Programming
Save Settings
C004386_07_CR2500_ User_Manual
-
25
Page 32
2.1 - Introduction By defining if you are scanning large, small, high denisty or low density types of symbology(s), the CR2500 has options that will maximize decoding speed. The chart below shows options that will improve performance based on parameters listed in each box.
SXGA
Both Fields
High Density Field
Wide Field
SB High Density Codes Standard Density Codes Small to Large Codes
SH High Density Codes Small Size 2D
SW Standard Density Codes Medium to Large Codes
The CR2500 is easily customizable; each trigger can be independently programmed for different behavior. High Density Field: The High Density Field can decode small bar codes. It has an optimal focal point of 3.3” ( 83.82 mm) away from the lens of the reader. See Figure 1.27 for optimal read distances. Wide Field: The Wide Field can decode standard size bar codes. It has an optimal focal point of 3.3” ( 83.82 mm) away from the lens of the reader. The following tables provide readable codes to program all or individual triggers to perform within different parameters. See Figure 1.28 for optimal read distances. The following tables provide the code to program all or individual triggers to perform with different parameters.
Save Settings
C004386_07_CR2500_User_Manual -
26
Page 33
2.2 - Global Trigger Optimization Matrix SXGA Both Fields
High Density Field
Wide Field
2.3 - Left Trigger Optimization Matrix SXGA Both Fields
High Density Field
Wide Field
Save Settings
C004386_07_CR2500_ User_Manual
-
27
Page 34
2.4 - Left Trigger Programming Scan the following codes to set the left trigger functionality: Left Trigger Take Picture
2.5 - Right Trigger Optimization Matrix SXGA Both Fields
High Density Field
Wide Field
2.6 - Right Trigger Programming Scan the following codes to set the right trigger functionality: Right Trigger Take Picture
Save Settings
C004386_07_CR2500_User_Manual -
28
Page 35
2.7 - Handle Optimization Matrix SXGA Both Fields
High Density Field
Wide Field
2.8 - Handle Trigger Programming Scan the following codes to turn picture taking mode on/off: Handle Trigger Take Picture
Save Settings
C004386_07_CR2500_ User_Manual
-
29
Page 36
2.9 - Continuous Trigger Optimization Matrix SXGA Both Fields
High Density Field
Wide Field
2.10 - Continuous Scan Scan the following codes to turn continuous scanning on/off: Off (Default)
Save Settings
On
C004386_07_CR2500_User_Manual -
30