Page 10

1.5 - Powering On/Off Reader To power on the reader, press and hold either of the red trigger buttons for 3 seconds (Figure 1.9). The reader will power down after 2 hours of non-use. To change the default settings, please see Section 4.7 - Reader Power Off Settings.

Figure 1.9

1.6 - Batch Operation 1.6.1 - Introduction Batch data storage and data transfer are controlled by the resident JavaScript application on your CR2500 reader. Please consult the Code Viewer user manual for the application on your CR2500 for instructions on how to control data storage and transfer.

1.7 - Cabled Operation 1.7.1- Introduction The CR2500 is a Multi-Interface Unit (MIU) and is available with USB (6 ft. or 12 ft.), RS-232 (Serial) and PS/2 cables. All of the cables are connected to the CR2500 with a 8-pin DIN connector (Figure 1.3)

Hand Held CR2500 - To install a cable directly to the CR2500, correctly line up the 8-pin DIN connector into the back end of the reader. The arrows on the connector should be facing down (Figure 1.10). When the reader and the cable connector are lined up, firmly push the cable into the reader. The cable has a locking mechanism that will firmly hold the cable in place (Figure 1.11). To deattach the cable from the reader, you must pinch the plastic on the 8-pin DIN and pull back to disengage the connector.

Figure 1.10 Save Settings

Figure 1.11 C004386_07_CR2500_User_Manual -

4

Page 11

1.7 - Cabled Operation (continued) CR2500 with Cabled Handle - If a handle was purchased for use with the CR2500, the 8-pin DIN connector is at the bottom of the handle (Figure 1.2). Insert the 8-pin connector and firmly push the cable into the handle. The cable has a locking mechanism that will firmly hold the cable in place. If using the H2 cabled handle, for additional stability, there is an optional cable attachement clip that can secure the cable to the handle with two threaded screws (Figure 1.13).

Figure 1.13

Figure 1.12

1.7.2 - CR2500 as a USB Keyboard To connect the CR2500 to your host computer via USB interface: 1. Attach the USB cable to CR2500 (Figure 1.14). 2. There is no need to power of the computer, then connect the USB cable to a USB port on the computer (Figure 1.16). 3. Once properly connected, the CR2500 will power on and beep. 4. Scan the below code (M049_03) for USB Keyboard Mode:

USB Keyboard Factory Reset

7. Scan the Save Settings Code (M188_02):

Figure 1.14

Save Settings

Figure 1.15

Figure 1.16

C004386_07_CR2500_ User_Manual

-

5

Page 12

1.7.2.1 - Addional USB Communication Settings USB Keyboard Mode - Data is sent from the Reader and interpreted by the host just as if a US keyboard was being used to enter data. USB Downloader - This mode is used when downloading firmware. USB Native Two Way Mode - This mode is utilized when there is a need for error-corrected communication between the CR2500 and an application through the USB port. USB Virtual COM 1 Way Mode - This mode allows a USB-cabled CR2500 to function as a virtual COM port. To use the CR2500 in this mode, download the driver at www.codecorp.com/downloads.php. USB HID POS (Terminal ID 131) - This mode allows a USB-cabled CR2500 to communicate as a USB HID POS (Terminal ID 131) device. Scan the following codes to set the appropriate USB communication setting: USB Keyboard

USB Downloader

USB Native Two Way Mode

USB Virtual COM 1 Way Mode

USB HID POS (Terminal ID 131)

Save Settings

C004386_07_CR2500_User_Manual -

6

Page 13

1.7.2.2 - Keyboard Support Scan the following codes to set appropriate keyboard mapping: US English (Default) No Leading 0 for non-printable characters

French

German

Custom Keyboard

US English - Leading 0 for non-printable characters

Japanese

Alternative OS (Windows CE/MAC/Unix/Linux) Enable

US English - ctrl + char for non-printable characters

Universal Keyboard

Alternative OS Disable

Requests map to be installed

Save Settings

C004386_07_CR2500_ User_Manual

-

7

Page 14

1.7.3 - PS/2 Cable Installation Guide 1. Power off the computer. If you disconnect the computer’s keyboard while it is powered on, your computer will lock up. 2. Attach the the PS/2 cable to the CR2500. 3. If you have a cabled keyboard, detach the keyboard cable from the computer and connect that same connector to the female connection on the CR2500 PS/2 cable (Figure 1.17). 4. Now connect the male CR2500 PS/2 connector into the keyboard port on the computer (Figure 1.18). 5. Power on the computer. The CR2500 is powered by the PS/2 port and does not require a power supply. 6. Once properly connected, the CR2500 will power on and beep.

Figure 1.17

PS/2 Factory Reset

Figure 1.18

Save Settings Code does not guarantee compatibility with all models of computers.

Save Settings

C004386_07_CR2500_User_Manual -

8

Page 15

1.7.4 - RS-232 (Serial) Cable Installation Guide 1. Attach the RS-232 (Serial) Cable to the CR2500. 2. Connect the RS-232 (Serial) cable to a serial port on the computer (Figure 1.19). There is no need to power off the computer. 3. The RS-232 (Serial) interface has an optional 5V/1.5A power supply (Figure 1.20). If you have a power supply, plug the power supply adapter into the RS-232 (Serial) cable and then plug the power adapter into a wall socket (Figure 1.21).

Figure 1.19

Figure 1.20

Figure 1.21

4. Once properly connected, the CR2500 will power on and beep. 5. For RS-232 (Serial) mode scan M418_02 (below). If the power supply is not connected scan M074_02 (below). 6. Scan the Save Settings Code (M188_02). RS-232 (Serial) Factory Reset

RS-232 (Serial) Mode No Power Supply

RS-232 (Serial) Save Settings

Factory Default Settings Mode: RS-232 (Serial) One Way Mode Baud Rate: 57600 Stop Bits: 2 Data Bits: 8 Parity: None

Warning: Code Corporation approved power adapter must be used. Reader failure due to use of incorrect power adapter will void warranties.

Save Settings

C004386_07_CR2500_ User_Manual

-

9

Page 16

1.7.4.1 - Additional RS-232 (Serial) Communication Data Bit Settings Scan the following codes to set the appropriate data bit: 7 Data Bits

8 Data Bits (Default)

1.7.4.2 - Additional RS-232 (Serial) Communication Baud Rate Settings Scan the following codes to set the appropriate baud rate: 1200

2400

4800

9600

19200

38400

57600 (Default)

115200

1.7.4.3 - Additional RS-232 (Serial) Communication Parity Settings Scan the following codes to set parity: Even

Save Settings

Odd

None (Default)

C004386_07_CR2500_User_Manual -

10

Page 17

1.8 - Bluetooth Radio Operation 1.8.1 - Introduction The CR2500 features a Bluetooth® wireless radio. The radio allows for point-to-point wireless communication with other Bluetooth devices that support serial port protocol (SPP). If keyboard entry is necessary, CodeXML® Router will need to be installed. The following guide will give you general instructions on connecting your CR2500 to a desktop or laptop computer with a Bluetooth radio. Connecting With A QuickConnect Code The easiest way to connect to a Bluetooth device is to visit the Code website and create a QuickConnect Code that is specific to your device (Figure 1.22). This code will link your CR2500 directly to the desired Bluetooth device. To create a QuickConnect Code, you will need to know the Bluetooth address (often referred to as the BD_ADDR) of that device. You can usually find the 12-character Bluetooth address somewhere on the device near the device’s serial number (see Figure 1.23).

Figure 1.22

Figure 1.23

If you purchased a CodeXML® Bluetooth Modem or a Belkin® Bluetooth adapter from Code or from an authorized distributor, a QuickConnect Code was included. If you bought a Bluetooth adapter separately and wish to create a QuickConnect Code, please visit Code’s web site at: http://www.codecorp.com/bdaddr.php. Important Note: You will need to locate the Communications (COM) Port assigned to the Bluetooth serial port protocol. While installing the Bluetooth Configuration Manager Software that was included with your Bluetooth adapter, make sure to note the Communications (COM) Port number the software assigned for the adapter (e.g., COM 10). This is the COM Port through which the CR2500 will connect. To connect your reader, use the following steps: 1. Power on the CR2500 reader by pressing one of the red buttons for one second to power on the reader. 2. Scan the Reset to RF Factory Defaults Code (M684_01). 3. Scan the Quick Connect Code you receieved or created from Code’s website. 4. The CR2500 will automatically connect to the computer. By default, the CR2500 will beep once after it connects and beep four times in a row if it did not connect. 5. Scan the Save Settings Code (M188_02) if you want to save the wireless connection settings to the CR2500 so that the CR2500 will automatically try to connect wirelessly the next time it is powered on.

Reset to RF Factory Defaults

Save Settings

Example: QuickConnect

Save Settings

C004386_07_CR2500_ User_Manual

-

11

Page 18

1.8 - Bluetooth Radio Operation (continued) Radio Range and Transferring Data The CR2500 radio is a Class 1 device. If connected to another Class 1 device the reader has roughly a 100 meter (300 feet) line of sight operating range. If connecting to a Class 2 or Class 3 device, the operating range may drop to match the lower range. Once a reader is connected, a serial application must be opened (HyperTerminal) unless CodeXML® Router is installed. When the CR2500 detects the radio is out of range, the CR2500 will store data on the reader’s non-volatile memory. The reader will continue to try and send data until radio is back in range. Once the data is sent the data will be erased from the reader’s memory. The reader will continue to try and connect until it has reached the programmable radio time out setting. The CR2500 Bluetooth protocol allows for two (2) forms of communication: 1.

Standard Bluetooth Reliability Mode (previously One Way Mode) - Communication between the reader and host, that does not require host acknowledgement. This mode is only recommended when connecting to a device well within its specified range or if connecting to a simple device (e.g., printer). There are two settings in this mode: • Max Range (Default) - Greater range but data reliability is lower • Max Reliability - Limits range but reliability is improved RF Standard Bluetooth Reliability Mode (Max Range)

RF Standard Bluetooth Reliablility Mode (Max Reliability)

Note: One Way Mode doesn’t guarantee data integrity, and you may have data loss when operating in the fringes of radio range or in the presence of radio interference. 2.

Additional Bluetooth Reliability Mode (previously Two Way Mode) - This mode requires the implementation of software at the application level.* The reader receives confirmation via packet protocol verification and is 100% reliable. Data will be automatically retransmitted if necessary. RF Additional Bluetooth Reliability Mode

* Note: You will need either CodeXML® Router Software or a CodeXML® Bluetooth Modem on the PC side to use the Additional Bluetooth Reliability Mode. If you are using the CodeXML® Bluetooth Modem, you must use RF Additional Bluetooth Reliability Mode.

Save Settings

C004386_07_CR2500_User_Manual -

12