Page 41

Genus™ G2 Users Manual

Genus™ WiFi Configuration/Setup WiFi Module The WiFi Modules are shipped with DHCP disabled, and all security modes turned off. If the Module successfully associates with an access point, the Link and Power LEDs will be green. If the Module is unable to associate with an access point, the Link LED will blink red and the Power LED will be green in color. WiFi Module - Fallback If DHCP is enabled and the WiFi Module has been powered up for 60 seconds without being able to associate with an access point, the Module will fallback to the following settings: IP address: Subnet Mask: Gateway IP:

192.168.0.68 255.255.255.0 0.0.0.0

When the Module reaches the 60 second timeout, it will revert back to the fallback settings. The Power LED will change from amber to green and the Link LED will continue to blink red.

Genus™ Terminal The Genus™ terminal must also have a valid IP address (Terminal DHCP turned off) in which the first three octets are 192.168.0.XXX, otherwise the Terminal will not be able to communicate with the WiFi Module installed.

DHCP and WiFi Module setup Upon entering setup mode the user is given the option to enable (select check box) or disable DHCP for the WiFi Module. If DHCP is disabled, the Terminal will prompt the user to enter network settings for the Module. These settings are stored by the Terminal allowing it to be able to go back into setup again as needed. If DHCP is enabled, and the Module is assigned an IP address by the DHCP server, the Terminal will not know the Module’s IP setting and will not be able to go into setup. However, the need to go back into setup once the Module associates with an access point and is running is unlikely. If there is a need to go into setup, the access point would have to be powered down or the Terminal would have to be moved out of range. After 60 seconds, the WiFi Module will revert back to its fallback settings and the user will be able to go into setup.

Revision –

6-15-06

40

Page 42

Genus™ G2 Users Manual Genus G2 Initial Setup screen When Genus™ powers up it displays its power up sequence of screens and arrives at the following Terminal Information screen on the G2 Terminal.

Use Right Arrow key

Use the right arrow key to advance and highlight Net. The following Network setup screen will appear. Use TAB key

Use SEL key to confirm WiFi Setup selection

Use Then press

Revision – to advance through the network setup fields until ‘WiFi Setup’ is highlighted. to get to WiFi Network Setup screen.

6-15-06

41

Page 43

Genus™ G2 Users Manual WiFi Information The WiFi information is also available from the initial ‘Network Setup’ display. WiFi information provides a resource for firmware and version releases and Link connectivity status.

Use to advance to and highlight ‘WiFi Info’. Then press to view the current information.

WiFi Link Status Depending on the connectivity of the WiFi module and the network, the Link status will provide messages indicating the current status of the connection. These messages are as follows: Association Incomp. Connected Disconnected AP Change AP out of range AP in range Association failed Refer to the WiFi LED Descriptions in this section for further information on Link status as associated with the WiFi Module LED colors.

Revision –

6-15-06

42

Page 44

Genus™ G2 Users Manual WiFi Network Setup After ‘WiFi Setup’ has been selected from the Network setup screen the G2 Terminal will arrive at the WiFi Network Setup. Active keys: Once entered into the WiFi Network Setup additional keys become active on the G2 Terminal to assist with the parameter changes. Select (SEL)

Enables or disables the DHCP checkbox

Left and Right Arrows Tab Delete (DEL) and Backspace (BS) UP and Down Arrows Clear Select (SEL) and Enter

Position cursor within parameters Advances through all parameters displayed Edit at cursor location Scroll through available options, alphanumeric characters and subnet mask octets at parameter locations Suspends entry and returns to terminal network settings Accept CANCEL once highlighted to return to terminal network settings

Select (SEL) and Enter

Accept NEXT once highlighted to advance to the next screen

Select (SEL) and Enter

Accept APPLY once highlighted to save the changed parameters to the WiFi Module, (this appears on the security settings screen)

Enable DHCP: Use to check enable or uncheck to disable DHCP. Use to advance through the network settings. WiFi Primary Network Settings are standard network parameters that follow the enable DHCP prompt on the WiFi Network Setup screen. Primary Network Settings; IP: Subnet Mask: Gateway IP: Primary DNS: Secondary DNS:

Revision –

6-15-06

43

Page 45

Genus™ G2 Users Manual WiFi Module Fallback Settings Fallback mode can occur when the WiFi module is unable to associate with an access point after 60 seconds. The Terminal recognizes these settings and will allow a setup session. The LEDs on the Module revert to the Power LED changing from amber to green and the Link LED will continue to blink red.

Fallback IP Default is: 192.168.000.068. Fallback Subnet Default is: 255.255.255.0. Fallback Gateway Default is: 000.000.000.000.

Revision –

6-15-06

44

Page 46

Genus™ G2 Users Manual WiFi Module Security Settings The WiFi Module provides security setting options, with the default set to disabled. Each security field is available to enter settings as needed depending on the security chosen. Security options are wep64, wep128, and wpa-psk.

SSID: The default value for the SSID is “any”. The SSID can be up to 31 characters. This controls which AP the Module connects to. If using a digital wand, refer to the Code 39 Programming Table in this document.

Security Mode: Scroll through the security wep64, wep128, wpa-psk and disable options.

WPA-PSK refers to Pre-Shared Key used in Authentication. This is a shared key between the station and the access point (AP) and is entered as a passphrase. WPA-PSK passphrase Input is 8 to 63 ASCII characters or 64 hex characters and cannot contain spaces. The passphrase must match the passphrase on the AP. If using a digital wand, refer to the Code 39 Programming Table in this document. Note: If too few characters are entered for Passphrase or WEPkeys the terminal will beep in error.

Revision –

6-15-06

45

Page 47

Genus™ G2 Users Manual WEP64 refers to 64-bit key length assigned to the WiFi Module that must match the access point on the network. The WEP Authentication type can be configured for auto, open or shared. Auto is the default setting and will automatically detect the authentication. Open authenticates using open Key algorithm, and will communicate the key across the network. Shared authenticates using Shared Key algorithm, and will allow communication only with devices with identical WEP settings. The Default Key option must match the key index configured on the Access Point. The options are 1, 2, 3, 4, with the default set as 1. WEP Keys, there are four WEP Key input areas to add the ASCII HEX values. These correspond to the number as chosen through the Default Key above. WEP 64 requires 10 hex digits that are entered in WEP Key areas 1-4. Acceptable characters include only 0-9, and A-F, in upper case. If using a digital wand refer to the Code 39 Programming Table in this document. WEP128 refers to 128-bit key length assigned to the WiFi Module that must match the access point on the network. Wep128 works the same as wep64 described above with a requirement of 26 ASCII HEX digits that are entered in WEP Key areas 1-4.

Revision –

6-15-06

46

Page 48

Genus™ G2 Users Manual

Troubleshooting Genus™ WiFi Issues Issue

Resolution

The WiFi Module cannot find the Access Point.

Verify that the Link LED is solid green. If it isn’t, refer to “LED Troubleshooting” table.

The AP (Access Point) cannot find the WiFi Module.

Click the Refresh button in your Access Point’s configuration application. If the problem remains, check the WiFi Module’s physical connections. Then power-down the WiFi Module, power it up, and check the LED status. The “WiFi LED Description” table defines the various LED status indications. Make sure that there is not another AP in the area that may be interfering with your AP. If the problem remains, contact CMI.

The WiFi Module cannot associate with an Access Point.

Change the location of the WiFi Module to improve reception. If that does not help, go into the WiFi configuration and be sure the SSID matches that of the Access Point (remember the SSID is case sensitive). Also verify that the security settings such as WEP keys or WPA PASSPHRASE match the AP exactly.

The Genus™ terminal cannot access the WiFi Module for setup purposes

Most likely the Terminal does not know what the IP address of the WiFi Module is. This will happen if the Module is set for DHCP and the Module obtains an IP from the server. The Terminal will be able to access the Module by using the WiFi Module’s fallback IP address. The WiFi Module will revert back to the fallback Ethernet settings after 60 seconds if it is moved out of range of the AP or if the AP is powered down. Fallback mode is indicated when the Power LED changes from amber to green and the Link LED is blinking red. Default fallback Ethernet settings IP address: 192.168.0.68 Subnet Mask: 255.255.255.0 Gateway IP: 0.0.0.0 DHCP must be turned off in the Genus™ terminal and fixed address settings entered that match the above values. The first three octets of the Terminal must match the address above. The last octet must be something other than 68.

The Genus™ terminal still cannot access the WiFi Module after “fallback” has occurred.

Revision –

The fallback Ethernet settings have been changed to something other than the default values. The default values can be restored to the WiFi Module by turning the Module on while holding the reset button momentarily. All user changed values will be defaulted.

6-15-06

47

Page 49

Genus™ G2 Users Manual Indicator LED Troubleshooting Table If the...

Perform These Tasks...

Power LED does not turn On.

Check power connector is properly inserted.

Power LED turns Red.

Remove power and re-apply. If the Power LED remains Red, contact CMI.

Power LED is Amber.

WiFi Module has not established an IP address either through DHCP or Static methods. If DHCP is enabled your network must have a DHCP server available when the WiFi Module is powered-up. Most AP/Routers have a DHCP server built-in. Enable your DHCP server and re-start the Module.

Link LED continues to Blink Red.

WiFi Module has not found an Access Point with which to associate. Be sure the Access Point you want to use is turned on and has WEP disabled (you can enable WEP after the WiFi Module has been configured). If this does not help, be sure there are no nearby devices causing interference. If there are, either turn off or move the device causing the interference or move the WiFi Module and Access Point to another location.

Comm LED is Off or Amber.

Be sure the Genus™ terminal is connected to the WiFi Module and that the device is turned on.

Comm LED is Red and Link LED is Green but you are unable to pass data.

Check the Ethernet settings of the Genus™ terminal. Except for the last octet of the IP address, all settings should match those of the WiFi Module. If the Terminal is set for DHCP, your network must have a DHCP server available when the Genus™ Terminal is powered-up.

Revision –

6-15-06

48

Page 50

Genus™ G2 Users Manual WiFi LED Description LED

Comm

Link

Power

Revision –

LED Color

Function

Off

No power, or no wireless TCP session is established and no Ethernet physical connection is detected.

Red

No wireless TCP session is established; an Ethernet physical connection is detected.

Blinking Red

An Ethernet physical connection was detected and there is Ethernet traffic present on that connection, but no wireless TCP session is established.

Amber

A wireless TCP connection is established but no physical Ethernet connection is detected (i.e., no Ethernet cable is attached to the Module).

Blinking Amber

A wireless TCP session is established, a physical Ethernet connection is detected, and the Module is transmitting or receiving data across the wired Ethernet port.

Green

A wireless TCP session is established, a physical Ethernet connection is detected, but there is no active data movement across the wired Ethernet port.

Off

Module is not receiving power.

Blinking Red

Module is searching for an Access Point.

Green

Wireless network and MAC have associated with an Access Point.

Off

Module is not receiving power.

Red

Module failed its Power On Self Test (POST) and is not configured for wireless communication.

Amber

Module passed its POST but is not configured for wireless communication.

Green

Module passed its POST and is configured for wireless communication.