Page 46

Genus™ G1 Users Manual

Troubleshooting Terminal Issues Terminal Issue

Possible Causes

Resolution

Terminal does not power on

No Power to the terminal.

Verify power cable is connected to terminal. If a UPS is included verify power is connected to the UPS and the power cable from the UPS is connected to the Terminal.

Loader screen does not show; only the copyright screen then it goes blank

Loader is missing or has become corrupt.

Refer to the Service and Technical Support section in this document.

Genus executable has become corrupt or needs to be programmed.

Reload Genus to the terminal. Refer to Steps to Re-Program Genus Firmware section in this document.

Terminal stops at “Initializing network”

Terminal is searching for DHCP and/or Network connection is not available.

Wait at least 3 minutes. Make sure your network cable and switch are connected and working properly.

Terminal shows “Serial Loader Mode”

Terminal does not have a usable copy of Genus or Default.

Refer to the Service and Technical Support section in this document.

Copyright 2005 by Control Module Inc. Program: PS00344 Released: 04/09/05

Default loads all the time after Loader

Loading Default

Revision –

6-23-06

45

Page 47

Genus™ G1 Users Manual Terminal Issue Terminal shows “Error opening Classes.jar”

Possible Causes

Resolution

Terminal does not have the Classes (or API) loaded.

Reload Classes to the terminal. Refer to Steps to Re-Program Genus Firmware section in this document.

Terminal does not have an application loaded.

Load Application to the terminal. Refer to Loading a Customer Defined Java Application section in this document.

The SRAM on the memory board could be failing.

Refer to the Service and Technical Support section in this document.

The Real Time Clock is not functioning.

Refer to the Service and Technical Support section in this document.

A device could be connected to the tamper.

Remove any connection to the tamper.

Error Opening Classes.jar

Terminal shows “Error opening App.jar” Error Opening App.jar

Terminal shows “Error initializing RAM File System” Error Initializing RAM File System

Terminal shows “Error initializing RTC” Error Initializing RTC

Terminal starts up and displays “Enter IP Address:” Enter IP Address:

192.168.000.062

Revision –

6-23-06

46

Page 48

Genus™ G1 Users Manual

Reference Steps to Re-Program Genus Firmware: In the event an update becomes available for the Genus terminal, the firmware can be updated in the field. The following items are required to (re-)program Genus firmware:

Data terminal to be programmed, connected to the network the IP address of the Genus terminal computer / laptop connected to the network and able to PING the data terminal Genus firmware

Genus (“System”) file update: The Genus terminal application makes use of CMI Java classes and interfaces in the CMI Genus API. tftp –i PUT <ip address> Genus \flashdisk\Genus (Note: Genus file name may be versioned (e.g. g2_3_3_12) Classes (API) update: The classes file is specific to your terminal type (G1 or G2). Check the release notes or other documentation provided with the updated files to confirm the name of Classes.jar (may be GI.jar or GII.jar). tftp –i PUT <ip address> Classes.jar \flashdisk\Classes.jar

Note: The terminal will reboot after replacing the Genus or Classes files Wait until the terminal reboots before sending additional files.

Confirming Updates: To confirm that the Genus and/or Classes update(s) took place, follow the steps below: 1) Place the terminal in Offline mode 2) Locate the “Terminal Information” screen 3) Check “API:” to find Classes version. 4) Scroll to “Program Version:” to locate Genus Version. Revision –

6-23-06

47

Page 49

Genus™ G1 Users Manual

Loading A Customer Defined Java Application This application runs on the terminal and handles both a user interface and any backend processing or communication. This is created by the user of the terminal, a value added Reseller, or CMI. tftp -i PUT <ip address> <myapp.jar> \flashdisk\App.jar where <myapp.jar> is the local name of the user created Java application. Important Note: The terminal will reboot after sending the file above. See the Genus Software Development Kit (SDK) for more information on creating terminal applications.

Revision –

6-23-06

48

Page 50

Genus™ G1 Users Manual

Programming Table (Code 39) This table provides Code 39 barcode access to special characters that are not available on the Genus™ terminal keypad. By using a digital barcode wand, these individual characters can be entered into the network setup parameters prompted by the Terminal.

Revision –

6-23-06

49

Page 51 read from a scan by OCR; it may hold reading errors

MA Miffficon rec MODULE INC. Genus™ G1 Users Manual

Wh WNth WM Wh Wi ! " # $ vi WMI Wh WN WN Wi & ' ( ) x

UL Wt MM Wii vill | | | WMI Wh Wi TL Wi ? < = S 2 UL ‘TL Mi Wi WM - a LC \ J WL MM MU WM Mi A, . { | WU MM } HL

Revision, 6-23-06 50

Page 52

Genus™ G1 Users Manual

Service & Technical Support If you are an End User that has been working with one of our Value Added Resellers, please call your VAR as the first point of contact prior to calling direct to CMI’s Service Department. Customers with Support Contracts should contact CMI Service at the number listed below.

PLEASE HAVE THE FOLLOWING INFORMATION AVAILABLE WHEN CALLING SERVICE.

Customer Number:

Phone #

Customer P.O.#

Fax #

Contact:

E-mail:

Company: Address: City/State/Zip Ship To:

Serial #

Quantity:

Problem

SERVICE & TECHNICAL

Model #

Several Time & Material plans are available to choose from and will be explained by a CMI Representative when you call in for service. Our Service numbers: 1-800-527-4998, CT customers please use 1-860-741-2830 Our Technical Support Number: 888-753-8222 Hours of Operation: M-F, 8:00 A.M. – 4:30 P.M. EST excluding holidays

Revision –

6-23-06

51

Page 53 read from a scan by OCR; it may hold reading errors

AMM} Mfffcanerren MODULE INC. Genus™ G1 Users Manual

Revision, 6-23-06 52