For the CMI Genus G1

Page 37

Genus™ G1 Users Manual WiFi Module Setup screens The Genus™ terminal needs to be in the Offline mode to get to the WiFi setup. WIFI NETWORK SETUP?

<UP><DWN><E>

Enable DHCP: No – disables DHCP and requires the user to enter network parameters. Yes – enables DHCP and the network parameters are assigned by the DHCP server.

WIFI NETWORK SETUP <UP><DWN><E><H> ENABLE DHCP No

With DHCP disabled the Terminal will prompt for network settings. IP: WIFI NETWORK SETUP <0-9><E> WIFI MODULE IP: 192.168.000.068

Subnet Mask: WIFI NETWORK SETUP <UP><DWN><E> SUBNET MASK: 255.255.255.0

Gateway IP: WIFI NETWORK SETUP <0-9><E> GATEWAY IP: 000.000.000.000

Primary DNS: WIFI NETWORK SETUP <0-9><E> PRIMARY DNS: 192.168.000.001

Secondary DNS: WIFI NETWORK SETUP <0-9><E> SECONDARY DNS: 000.000.000.000

Revision –

6-23-06

36

Page 38

Genus™ G1 Users Manual

SSID: The default value for the SSID is “any”. The SSID can be up to 31 characters. This controls which AP the Module connects to. If using a digital wand refer to the Code 39 Programming Table in this document. Security Type: The default is set to disabled. However, the Module provides, wep64, wep128, wpa-psk, options. See WiFi Module Security Settings, in this manual. Save Changes? Changes saved by ‘E’ will be saved to the WiFi Module. ‘H’ aborts the setup changes placing the user at the first prompt for DHCP enable/disable.

WIFI NETWORK SETUP <UP><DWN><0-9><E> SSID: any

WIFI NETWORK SETUP <UP><DWN><E> SECURITY TYPE: disable

WIFI NETWORK SETUP <E><H> SAVE CHANGES? ‘E’=SAVE ‘H’=ABORT

WiFi Module Fallback Settings Fallback mode can occur when the WiFi module is unable to associate with an access point after 60 seconds. The Terminal recognizes these settings and will allow a setup session. The LEDs on the Module revert to the Power LED changing from amber to green and the Link LED will continue to blink red. Enable DHCP: Yes while in setup will bring up the Fallback settings prompt.

If “Yes” is entered the fallback settings from the Module become available to change. If “No” is entered the Module returns to the SSID prompt. Fallback IP: Default is 192.168.000.068.

Revision –

6-23-06

WIFI NETWORK SETUP <UP><DWN><E><H> ENABLE DHCP Yes

WIFI NETWORK SETUP <UP><DWN><E> FALLBACK SETTINGS: Yes

WIFI NETWORK SETUP <0-9><E> FALLBACK IP: 192.168.000.068

37

Page 39

Genus™ G1 Users Manual Fallback Subnet: Default is 255.255.255.0.

WIFI NETWORK SETUP <UP><DWN><E> FALLBACK SUBNET: 255.255.255.0

Fallback Gateway: Default is 000.000.000.000.

Revision –

WIFI NETWORK SETUP <0-9><E> FALLBACK GATEWAY: 000.000.000.000

6-23-06

38

Page 40

Genus™ G1 Users Manual WiFi Module Security Settings The WiFi Module provides security setting options. With the default set to disabled each security field is available to enter settings as needed depending on the security chose. Scroll through the security types, wep64, wep128, wpa-psk, and disable. Press ‘E’ to choose.

WIFI NETWORK SETUP <UP><DWN><E> SECURITY TYPE: disable

WIFI NETWORK SETUP <UP><DWN><E> SECURITY TYPE: wep64

WIFI NETWORK SETUP <UP><DWN><E> SECURITY TYPE: wep128

WIFI NETWORK SETUP <UP><DWN><E> SECURITY TYPE: wpa-psk

WPA-PSK refers to Pre-Shared Key used in Authentication.

This is a shared key between the station and the access point (AP) and is entered as a passphrase. Input is 8 to 63 ASCII characters or 64 hex characters that cannot contain spaces. The passphrase must match the passphrase on the AP. When the passphrase has been entered use either ‘E’ to Save or ‘H’ to Abort.

WIFI NETWORK SETUP <UP><DWN><0-9><E> SECURITY TYPE: wpa-psk

WIFI NETWORK SETUP <UP><DWN><0-9><E> WPA PASSPHRASE

WIFI NETWORK SETUP <E><H> SAVE CHANGES? ‘E’=SAVE ‘H’=ABORT

If using a digital wand, refer to the Code 39 Programming Table in this document. Note: The G1 Terminal requires the exact number of hex characters for Passphrase and WEPkey values to advance to the next parameter setting.

Revision –

6-23-06

39

Page 41

Genus™ G1 Users Manual WEP64 refers to 64-bit key length assigned to the WiFi Module that must match the access point on the network.

The WEP Authentication type can be configured for auto, open or shared. Auto is the default and will automatically detect the authentication. Open authenticates using open Key algorithm, and will communicate the key across the network. Shared authenticates using Shared Key algorithm, and will allow communication only with devices with identical WEP settings. The Default Key option must match the key index configured on the Access Point. The options are 1, 2, 3, 4, with the default set to 1. There are four WEP Key input areas to add the ASCII HEX values. These correspond to the numbers as chosen through the default key above. WEP 64 requires 10 hex digits. Default is shown. Acceptable characters include only 0-9, and A-F, in upper case. If using a digital wand refer to the Code 39 Programming Table in this document.

WIFI NETWORK SETUP <UP><DWN><0-9><E> SECURITY TYPE: wep64

WIFI NETWORK SETUP <UP><DWN><E> AUTHENTICATION: auto

WIFI NETWORK SETUP <UP><DWN><E> DEFAULT KEY: 1

WIFI NETWORK SETUP <UP><DWN><0-9><E> WEP KEY 1: 0

WIFI NETWORK SETUP <UP><DWN><0-9><E> WEP KEY 2:

WIFI NETWORK SETUP <UP><DWN><0-9><E> WEP KEY 3:

WIFI NETWORK SETUP <UP><DWN><0-9><E> WEP KEY 4:

Revision –

6-23-06

40

Page 42

Genus™ G1 Users Manual When desired changes have been entered use either ‘E’ to Save or ‘H’ to Abort.

WEP128 refers to 128-bit key length assigned to the WiFi Module that must match the access point on the network.

WIFI NETWORK SETUP <E><H> SAVE CHANGES? ‘E’=SAVE ‘H’=ABORT

WIFI NETWORK SETUP <UP><DWN><0-9><E> SECURITY TYPE: wep128

Wep128 works the same as wep64 described above with a requirement of 26 ASCII HEX digits that must be entered in the Wep Key areas 1-4.

Revision –

6-23-06

41

Page 43

Genus™ G1 Users Manual

Troubleshooting Genus™ WiFi Troubleshooting Suggestions Table Issue

Resolution

The WiFi Module cannot find the Access Point.

Verify that the Link LED is solid green. If it isn’t, refer to “LED Troubleshooting” table.

The AP (Access Point) cannot find the WiFi Module.

Click the Refresh button in your Access Point’s configuration application. If the problem remains, check the WiFi Module’s physical connections. Then power-down the WiFi Module, power it up, and check the LED status. The “WiFi LED Description” table defines the various LED status indications. Make sure that there is not another AP in the area that may be interfering with your AP. If the problem remains, contact CMI.

The WiFi Module cannot associate with an Access Point.

Change the location of the WiFi Module to improve reception. If that does not help, go into the WiFi configuration and be sure the SSID matches that of the Access Point (remember the SSID is case sensitive). Also verify that the security settings such as WEP keys or WPA PASSPHRASE match the AP exactly.

The Genus™ terminal cannot access the WiFi Module for setup purposes

Most likely the Terminal does not know the IP address of the WiFi Module. This will happen if the Module is set for DHCP and the Module obtains an IP from the server. The Terminal will be able to access the Module by using the WiFi Module’s fallback IP address. The WiFi Module will revert back to the fallback Ethernet settings after 60 seconds if it is moved out of range of the AP or if the AP is powered down. Fallback mode is indicated when the Power LED changes from amber to green and the Link LED is blinking red. Default Fallback Ethernet Settings IP address: 192.168.0.68 Subnet Mask: 255.255.255.0 Gateway IP: 0.0.0.0 DHCP must be turned off in the Genus™ terminal and fixed address settings entered that match the above values. The first three octets of the Terminal must match the address above. The last octet must be something other than 68.

The Genus™ terminal still cannot access the WiFi Module after “fallback” has occurred.

Revision –

The fallback Ethernet settings have been changed to something other than the default values. The default values can be restored to the WiFi Module by turning the Module on while holding the reset button momentarily. All user changed values will be defaulted.

6-23-06

42

Page 44

Genus™ G1 Users Manual Indicator LED Troubleshooting Table If the...

Perform These Tasks...

Power LED does not turn On.

Check power connector is properly inserted.

Power LED turns Red.

Remove power and re-apply. If the Power LED remains Red, contact CMI.

Power LED is Amber.

WiFi Module has not established an IP address either through DHCP or Static methods. If DHCP is enabled, your network must have a DHCP server available when the WiFi Module is powered-up. Most AP/Routers have a DHCP server built-in. Enable your DHCP server and re-start the Module.

Link LED continues to Blink Red.

WiFi Module has not found an Access Point with which to associate. Be sure the Access Point you want to use is turned on and has WEP disabled (you can enable WEP after the WiFi Module has been configured). If this does not help, be sure there are no nearby devices causing interference. If there are, either turn off or move the device causing the interference or move the WiFi Module and Access Point to another location.

Comm LED is Off or Amber.

Be sure the Genus™ terminal is connected to the WiFi Module and that the device is turned on.

Comm LED is Red and Link LED is Green but you are unable to pass data.

Check the Ethernet settings of the Genus™ terminal. Except for the last octet of the IP address, all settings should match those of the WiFi Module. If the Terminal is set for DHCP, your network must have a DHCP server available when the Genus™ Terminal is powered-up.

Revision –

6-23-06

43

Page 45

Genus™ G1 Users Manual WiFi LED Description LED

Comm

Link

Power

Revision –

LED Color

Function

Off

No power, or no wireless TCP session is established and no Ethernet physical connection is detected.

Red

No wireless TCP session is established; an Ethernet physical connection is detected.

Blinking Red

An Ethernet physical connection was detected and there is Ethernet traffic present on that connection, but no wireless TCP session is established.

Amber

A wireless TCP connection is established but no physical Ethernet connection is detected (i.e., no Ethernet cable is attached to the Module).

Blinking Amber

A wireless TCP session is established, a physical Ethernet connection is detected, and the Module is transmitting or receiving data across the wired Ethernet port.

Green

A wireless TCP session is established, a physical Ethernet connection is detected, but there is no active data movement across the wired Ethernet port.

Off

Module is not receiving power.

Blinking Red

Module is searching for an Access Point.

Green

Wireless network and MAC have associated with an Access Point.

Off

Module is not receiving power.

Red

Module failed its Power On Self Test (POST) and is not configured for wireless communication.

Amber

Module passed its POST but is not configured for wireless communication.

Green

Module passed its POST and is configured for wireless communication.

6-23-06

44