For the CMI Genus G1

Page 10

Genus™ G1 Users Manual Digital Input The digital input with tamper switch is included Connector 6 position Terminal Block with this terminal configuration. This option Pinouts: 1 = No Connection (N/C) detects attempts to interfere with normal 2 = GND operation of the terminal. A pluggable connector 3 = DI 1 is supplied with the terminal. 4 = DI 2 5 = DI 3 (TAMPER) 6 = No Connection (N/C) Digital Output The Digital Output configuration design supports Connector 5 position Terminal Block the option for both sourcing and non-sourcing Pinouts: DO. The DO is a Form C contact relay rated for 1 = Normally Open (N.O.) 1 amp @ 30V AC/DC. The DO can be used to 2 = Common (C) control or monitor doors, bells, and alarms. 3 = Normally Closed (N.C.) 4 = Ground 5 = Vunreg Power Port Power is supplied to the terminal via a CMI standard power port on the backplate of the terminal.

Connector 3 position locking Pinouts: 1 = Earth Ground 2 = +15V to 24VDC 3 = Power Ground

UPS An optional UPS is available to power the terminal in the event of a main power failure or brownout conditions.

Revision –

Connector 3 position locking Pinouts: 1 = Earth Ground 2 = +15V to 24VDC 3 = Power Ground

6-23-06

9

Page 11

Genus™ G1 Users Manual Module Options The Genus G1 Terminal provides UPS, Modem and WiFi Module Options. UPS 2050-010

UPS Module. The 2050-010 module provides backup power to the Genus™ G1 terminal and integrated readers and communications options in the event of a main power failure and brownout conditions. Battery. The 2050-010 module uses a Ni-Cd 8 cell arrangement (9.6V @ 1000 mAh) to provide DC backup power to the processor and I/O modules. It has a wide charging voltage range (+15VDC to +24VDC unregulated). The battery will have a full charge after 20 hours at a trickle charge rate.

Modem 2042-301

Modem Comm Module. The 2042-301 module provides communication level conversion from a standard Telco line to RS232 levels for Genus™ G1. 56K Baud Modem. The modem is a 56K baud Auto Answer/Auto Connect modem which connects via the RJ11 Telco Port (Modem Host). It features Data Mode v.92 (57600 BPS) and supports enhanced “AT” commands.

WiFi 3046-100 WiFi Comm Module. The 3046-100 communications module provides LAN and Internet connectivity with the standard Ethernet interface to applications. The module is interoperable with industry standard 802.11 LAN and Internet connectivity and provides advanced security standards such as WEP and WPA. It provides a complete, reliable transparent wireless connection between a G1 Terminal and a network host via an RF access point.

Revision –

6-23-06

10

Page 12

Genus™ G1 Users Manual

Installation The installation process proceeds with the bulleted items below. All installation steps are discussed in the Installation Guide for Genus G1 (3010-IG-0001), however, follow only those that apply to your installation requirements. • • • • • • • • • • • •

Revision –

Wall Mount Installation & Recommended Height Grounding the G1 Terminal Wand / Scanner and Ethernet Connections Serial Aux Port Connection Digital Input Connection Digital Output Connection Power and UPS Connections Modules WiFi Antenna WiFi Module Connections Modem Module Connections Close & lock the Terminal and Store the Key

6-23-06

11

Page 13

Genus™ G1 Users Manual

Power-Up Several displays with the following messages appear in sequence during the normal G1 Terminal power-up process. In addition, during power-up, the Genus G1 terminal also executes an internal firmware test. Loader G1 Control Module Inc. Program: 342-001 VX.XX.XX

G1 Loader splash screen displays program and version numbers

Followed by “Loading Genus” Loading Genus

Genus splash screen displays program and version numbers

Genus Control Module Inc. Program: 341-001 VX.XX.XX

Initializing Network displays the default IP of the terminal

Initalizing: Network IP:

Initializing Flash displays, and IP address remains for reference

192.168.0.62

Initalizing: Flash IP:

Initializing RTC

192.168.0.62

Initalizing: RTC IP:

Initializing System Files

192.168.0.62

Initalizing: System Files IP:

192.168.0.62

Initializing Java VM Initalizing: Java VM IP:

Revision –

6-23-06

192.168.0.62

12

Page 14

Genus™ G1 Users Manual

Online Mode Following installation and power-up the G1 Terminal has completed the boot process and transitions to a Java application that begins its functionality and data collection as defined by the user.

Starting: <user’s app>

If no user defined program has been loaded the terminal will display the CMI reader setup application.

See Loading a Customer Defined Java Application in the Reference section of this document.

Revision –

6-23-06

13

Page 15

Genus™ G1 Users Manual

Offline Mode The offline mode is utilized during installation and setup, when the functionality of the Genus™ G1 terminal needs to be tested or if the communications setup requires a change. To accomplish this, the Terminal must be placed in Offline Mode. Keypad Layout:

Entering Offline Offline Mode for the G1 Terminal Setup Mode is entered during power-up as the Terminal initializes. Press the and keys simultaneously from the keypad during the second set of power-on beeps. The second set of power-on beeps occur just after the following message. Initalizing: Java VM IP:

192.168.0.62

At this point as the Terminal beeps it transitions to the online application, unless the and keys are pressed. Starting: CMIApp

(note: CMIApp name may differ depending on what application is in the terminal).

When the and keys are pressed the display changes to the following message. Indicating the terminal has entered offline mode. Starting: Setup

Revision –

6-23-06

14

Page 16

Genus™ G1 Users Manual The Genus G1 terminal stops and waits at the ‘Terminal Info’ prompt for keypad entry, as shown below, unless a PIN number has been setup then the terminal will request a PIN: PIN previously set

No PIN set TERMINAL INFO?

ENTER PIN:

<UP><DWN><E>

<E-C>

Note: Enter PIN prompt will only appear if PIN number has been setup in “SETUP PIN” from main menu during a previous offline session.

Menu Options in Offline Setup Mode TERMINAL INFORMATION CLEAR RAM CLEAR FLASH NETWORK SETUP WIFI NETWORK SETUP WIFI NETWORK INFO QUICK CHECK COMM TEST READER SETUP SETUP PIN SETUP TIME ZONE DIAL-UP NETWORK TADMIN SETUP EXIT SETUP Use the arrow direction keys for Enter

Revision – and to scroll through the main menu. Press to select an option from the main menu and follow the key directions displayed.

6-23-06

15

Page 17

Genus™ G1 Users Manual

Offline Mode – User Operational Displays TERMINAL INFO Provides basic terminal hardware information. TERMINAL INFO?

Press Enter to select. <UP><DWN><E> or keys scroll through The terminal information such as:

Machine Name MAC Addr Hardware Version API Program Info Serial No MFGR Date

TERMINAL INFO? <UP><DWN><H> MACHINE NAME: GENUS408300

Terminal name assigned Displays terminal’s MAC Address For CMI reference Classes/API Version Genus/System version Provides service information (Note: may not match terminal serial #) For CMI reference

Press HOME to return to main menu options. Use the menu.

Revision – key to scroll to next item on

6-23-06

16

Page 18

Genus™ G1 Users Manual

CLEAR RAM Clears the ‘\ramdisk’ on the terminal, typically erasing transaction data. See the File System Specification for more detail on the data cleared.

CLEAR RAM?

Press to select. <UP><DWN><E>

CLEAR RAMDISK CLEAR RAM?

Press to CLEAR RAMDISK.

<E><H> CLEAR RAMDISK? ‘E’=YES ‘H’=ABORT

Press HOME to abort.

If is selected, a warning message will appear, as shown.

CLEAR RAM? <E><H> DATA WILL BE LOST! ‘E’=YES ‘H’=ABORT

User is required to press again to CLEAR RAMDISK or press HOME to abort.

Revision –

6-23-06

17