For the CMI Genus G1

Page 1 read from a scan by OCR; it may hold reading errors

LLL, Veon Trot MODULE INC.

Genus"™ G1 Users Manual

Page 2

Genus™ G1 Users Manual

Table of Contents Declarations .............................................................................................................................................. 2 Introduction............................................................................................................................................... 3 Genus™ G1 Terminal............................................................................................................................... 4 The User Interface .................................................................................................................................... 4 Terminal Features ..................................................................................................................................... 5 Terminal Hardware................................................................................................................................... 6 Terminal Connections............................................................................................................................... 8 Installation .............................................................................................................................................. 11 Power-Up ................................................................................................................................................ 12 Online Mode ........................................................................................................................................... 13 Offline Mode .......................................................................................................................................... 14 Entering Offline ...................................................................................................................................... 14 Offline Mode – User Operational Displays ............................................................................................ 16 Genus™ WiFi Installation ...................................................................................................................... 30 Troubleshooting Terminal Issues ........................................................................................................... 45 Reference ................................................................................................................................................ 47 Steps to Re-Program Genus Firmware: ............................................................................................... 47 Loading A Customer Defined Java Application..................................................................................... 48 Programming Table (Code 39) ............................................................................................................... 49 Service & Technical Support.................................................................................................................. 51

Disclaimer No part of this publication may be reproduced, or transmitted in any form or by any means without the written permission of Control Module, Inc. The information described by this publication is specifically intended for use by customers and resellers of Control Module Data Collection products and data collection systems and only for use with Control Module Data Collection products and data collection systems. The information in this manual is subject to change without notice and does not represent a commitment on the part on Control Module, Inc.

Revision –

6-23-06

1

Page 3

Genus™ G1 Users Manual

Declarations Control Module, Inc. Model: Genus™ G1 Serial: 3010

FCC Compliance The Control Module Model Genus™ G1 Time and Attendance Terminal conforms to the requirements of FCC PART 15, SUBPART B, CLASS A, 2004 for radiated and conducted emissions without modifications.

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Revision –

6-23-06

2

Page 4

Genus™ G1 Users Manual

Introduction Welcome to Control Module’s Genus™ G1 Data Collection Terminal. The “Genius of Genus” is that it offers an intelligent Java programming language and enables companies – for the first time – to realize the maximum potential of their workforce management terminals, by using them as a powerful interface to connect highly customized applications and the databases that fuel them. The Genus™ open and modular platform is designed to provide fast, accurate, and reliable data collection for any industrial application. The Genus™ Terminal is ideal for time and attendance, workforce management, employee self-service, shop floor data collection, and access control. Genus™ is the intelligent and affordable decision for any organization. Congratulations on your purchase!

Revision –

6-23-06

3

Page 5

Genus™ G1 Users Manual

Genus™ G1 Terminal Terminal features are labeled in the pictures below for reference. Explanations of terminal features, user interface, hardware specifications and connections follow.

Terminal Front 4X20 Character Backlit LCD Display

Optional Readers Include: Biometric Barcode Mag Track 1 Mag Track 2 Proximity Smart card

3X8 Membrane Keypad

The User Interface The user interface offers options for data entry into the Genus G1 terminal through the keypad and/or internal or external card readers. User output is via a 4 line by 20 character backlit LCD display. The terminal also has the capability to produce different tones to help guide the user. The Genus G1 terminal offers additional display control aside from the ability to write to and clear the entire display. These include the ability to clear a single display line, position the cursor, and select the cursor type (invisible, block, underscore, or blinking underscore).

Revision –

6-23-06

4

Page 6

Genus™ G1 Users Manual

Terminal Features Memory Configuration The Terminal is equipped with 32 Mb of dynamic memory, 2 Mb of non-volatile memory for data retention, and 8 Mb of Flash memory for program storage. An additional 32 Mb of Flash memory for user defined long term storage is available as an option. Programmability The Terminal is designed to be a Java-capable embedded data collection platform. Users may create, load, and execute J2ME Personal Profile 1.1 compliant applications that utilize existing OEM classes for display, keyboard, biometric, barcode, magnetic, proximity, Mifare, iClass, and Digital inputs and outputs (DI/DO). A software development kit (SDK) is available separately that provides development documentation, development support, and samples for the use of the OEM classes. Digital I/O The Terminal provides program control of integrated Digital Outputs for relay control, two (2) Digital Inputs, and includes a Tamper sense. Host Interface The Terminal comes with a dedicated Ethernet port for connection to 10/100 Ethernet networks. DHCP or static IP address configuration are supported. Display The Terminal is equipped with a 4 line by 20 character liquid crystal display (LCD) The full alphanumeric character set is supported. LED backlighting provides viewing in low light conditions. The display has a CMI standard lens. Keypad The Terminal is equipped with a 3 x 8 membrane keypad, with three horizontal rows of eight keys each. The terminal is available with a CMI Standard Overlay, or a custom overlay created per customer requirements. Power The configuration uses a 15 VDC 1 amp power pack to power the terminal. The power pack is UL listed and CSA certified. Audio Annunciator This is programmable with variable tone and duration capability.

Revision –

6-23-06

5

Page 7

Genus™ G1 Users Manual

Terminal Hardware Hardware Specifications Keypad - with local buffering 10 Numeric Keys (0 through 9) 6 Function Keys expandable to 27 using the shift key Function keys alternately can produce punctuation symbols. Clear and Enter Keys Home, Up, Down, Left, and Right arrows Shift key Display 4 Line by 20 Character Backlit LCD Display Media Readers 2 Internal reader ports, 1 External reader port, 1 Barcode wand port Magnetic Track 1 and 2 Barcode Code 39 and code 39 full ASCII, Interleaved 2of5, Code 128 Proximity allows up to a 99 bit badge (HID, Motorola) Smartcard (Mifare, iClass) Biometrics (Fingerprint) Beeper Variable duration monotone beep Variable duration warble beep Emit a series of beeps Host Interface RS232 10/100 Ethernet Modem option via serial port (PPP) WiFi option External Control Relay Output - 30VDC @ 1A Power Requirements 15 -24VDC Environment Operating 0°to 50°C (32° to 122°F) Storage -40° to 66°C (-40° to 151°F) Humidity 0 to 90 % non-condensing

Revision –

6-23-06

6

Page 8

Genus™ G1 Users Manual File System Specification The Terminal provides file systems on different hardware devices. Instead of using the common alphabet notation for file system devices ( ‘A:’, ‘C:’ ), the Genus terminal identifies the file storage devices as: Storage Device

‘\flashdisk’

‘\ramdisk’

‘\scratchdisk’

Memory size

Location

8 Mbytes std. (40Mb optional)

Seldom write, frequent read. Used for firmware, user applications, and application data.

2 Mbytes

High read/write usage. Data is preserved through power loss. Often used for transaction (punch) storage.

5 Mbytes

High read/write usage. Temporary file storage. Not preserved through power outage.

Relay Configuration The relay port brings out the three relay connections (common, normally open, normally closed) plus ground. The common can optionally be connected to an internal current source (nominally, 12 volts at 100mA - over-current protected). The internal current source is useful when driving external buzzers, lamps, or other low current, low voltage devices (or a larger external relay for that matter) since it requires no external power source. The Digital Output configuration design supports the option for both sourcing and nonsourcing DO. The DO is a Form C contact relay rated for 1 amp @ 30V AC/DC. Relay Port - Internal Power

Revision –

Pin

Function

1

Normally open contact

2

Common contact

3

Normally closed contact

4

Ground

5

VUNREG

6-23-06

7

Page 9

Genus™ G1 Users Manual

Terminal Connections Terminal Back

Ethernet Port The Ethernet port supports the 10/100BASE-T Connector: 8 position RJ45. Pinouts: network connections 1 = Receive + 2 = Receive – 3 = Transmit + 4 = Input Power

5 = Input Power 6 = Transmit – 7 = GND 8 = GND

Serial Aux Port The Serial Aux port provides a serial connection Connector: 8 position RJ45. to interface to serial peripheral devices or for Pinouts: 1 = DCD modem communications. 2 = RXD 3 = TXD 4 = DTR

5 = GND 6 = DSR 7 = RTS 8 = CTS

Wand / Scanner Port The wand port maintains the standard CMI Connector 6 position RJ11 Pinouts: pinouts with the RJ11 connector. 1 = Shield 4 = N/C(No Connection) 2 = Ground 5 = Data 3 = +5 VDC 6 = Vunreg

Revision –

6-23-06

8